1. ALL WORK MA7FR/ALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPEC/F/CA77ONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST E9I770N
OF THE WSDOT/APWA STANDARDS AND SPECIFICA 77ONS.
2. THE HOURS OF WORK /N THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:JO AM TO
J.30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT
OF PUBLIC WORKS AT 425-430-7200. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL
BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS /N ADVANCE. THE
POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NO77FlED 24 HOURS IN
ADVANCE.
3 ALL CONSTRUCTION SHALL BE IN ACCORDANCE NhTH "STANDARD SPECIFICATIONS FOR
MUNICIPAL PUBLIC WORKS CONSIRUC77ONN PREPARED BY THE WASHINGTON STATE
CHAPTER AMER/CAN PUBLIC WORKS ASSOCIATION (APWA), LATEST ED177ON AND THE CITY
OF RENTON STANDARD SPECIFICA 7TONS.
4. ALL LOCA77ONS OF EX/STTNG U77LI77ES SHOWN ARE APPROX/MATE AND IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCA77ON SO AS TO
AVOID DAMAGE OR DISTURBANCE
5. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR
TO STAR77NC NEW CONSTRUC770N. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
SECURE ALL NECESSARY PERMITS PR/OR TO STAR77NG CONS 7RUC77ON (INSPECTION WILL
BE ACCOMPLISHED BY A REPRESEN TA 77 VE OF THE CITY OF RENTON). IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO N077FY THE U77LITY DEPARTMENT 24 HOURS //V
ADVANCE OF BACKFILLING ALL CONSTRUC770N.
6. CONTRACTOR /S SOLEL Y RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CON57RUC770N AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSIRUC77ON
S17F
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY
OTHER RELA7FD PERMITS PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS
9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER
CONSTRUC7ION /S /N PROGRESS
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS-BUIL T DRAWING OF
THE SANITARY SEWER SYS7FM W 11CH HAS BEEN STAMPED BY A LICENSED PROFESSIONAL
ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EWALL Y ON BOTH S/DES OF THE PIPE IN LA YERS WITH A
LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY
TAMP/NG EACH LA YER TO 95Z OF MAX/MUM DENS/TYTHESE COMPACTED LA YERS MUST
EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE
TRENCH M47FRIAL5 TO COMPLETE THE FILL OVER THE PIPE SHALL BE THE SAME AS
DESCRIBED.
12. OPEN CUT ROAD CROSSINGS FOR U77LITY TRENCHES ON EX/STING TRAWLED ROADWAY
SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHAN/CALL Y COMPACTED. CUTS INTO
EX/S77NG ASPHALT SHALL BE NEA7LINC CUT WITH A SAW /N A CON77N000S LINE A
TEMPORARY COLD MIX PATCH MUST BE PLACED IMMEDIA7EL Y AFTER BACKFILL AND
COMPACI7ON. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DA YS AND
SHALL BE PER CURRENT CITY OF RENTON STANDARDS.
IJ DA7UM SHALL BE CITY OF RENTON, NA VD 1988 (METERS) AND NAD 198311991 (METERS)
14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO
THE SA775FAC77ON OF lHE DEPARTMENT FOR THE PREVEN77ON OF ON -SITE EROSION
AFTER THE COMPLETION OF CONSTRUC770N.
15. ALL P/PE AND APPURTENANCES SHALL BE LAID ON A PROPERL Y PREPARED FOUNDA77ON
IN ACCORDANCE IMTH SEC77ON 7-023(1) OF THE CURRENT STATE OF WASH/NGTON
STANDARD SPECIRCA7701VS FOR ROAD AND BRIDGE CONS TRUC 770N. THIS SHALL INCLUDE
NECESSARY LEVELING OF THE 7RENCH BOTTOM OR 7HE TOP OF THE FOUNDA77ON
MATERIAL AS WELL AS PLACEMENT AND COMPAC77ON OF REQUIRED BEDDING MA7FRIAI TO
UNIFORM GRADE SO THA T THE EN77RE LENGTH OF PIPE WILL BE SUPPORTED ON A
UN/FORML Y DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE
AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POL YWNYL COLOR/DE (PVC) RUBBER GASKETFD A5TM D
3034, SOR J5, C900, OR DUCTTLE IRON CLASS 50. SANITARY SEWER FORCE MAIN TO BE
CEMENT LINED DUCTILE IRON PIPE CONFORMING TO LATEST REVISION OF AWWA C110
& C111, THICKNESS CL. 52.
17. IN UNIMPROVED AREAS, MANHOLE TO EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 18"
ABOVE FIN/SHED GRADE. IN PAVED AREAS, COVER MUST SLOPE /N ALL DIREC7701VS TO
MA TCH PA WNG.
18. ALL SANITARY SEWER IMPROVEMENTS SHALL BE CONSTRUCTED /N ACCORDANCE W/ /
THESE APPROVED PLANS. ANY DEVIA LION FROM THESE PLANS WILL REQUIRE APPROVAL
FROM THE OWNER, ENGINEER AND APPROPRIATE PUBLIC AGENC/ES.
19. L OCA 77ONS OF ROADWAYS, BUILDINGS AND PARKING AREAS SHOWN HEREON ARE
APPROX/MA 7F FOR DIMENSIONED L OCA 77ONS OF 77 ESE IMPROVEMENTS, REFER TO THE
ARCHITFC7URAL SITE PLAN. IMPROVEMENT AND STRUCTURE LOCA 77ONS SHALL BE FIELD
SET BY THE ENGINEER AS REQUIRED.
20. ALL MANHOLES SHALL BE PER THE CITY OF RENTON STANDARDS AND SPECIFICATIONS.
ALL MANHOLES SHALL HAVE A MIN/MUM 0.10 FOOT TO MAX/MUM 1.0 FOOT DROP BETWEEN
INVERT IN AND INVERT OUT. ALL MANHOLE COVERS SHALL BE ADJUSTED TO FINISH
GRADE PRIOR TO FINAL PAVING OR LANDSCAPING
21. ALL TRENCH BACKFILL SHALL BE COMPACTED TO A T LEAST 95X OF THE MAXIMUM DRY
DENSITY PER ASTM D-1557-70 (MODIFIED PROCTOR), FOR THE FIRST THREE FEET ABOVE
THE PIPE. THE REMAINING BACKFILL MAY BE TO 9OX IF NOT IN AN AREA OF FUTURE
PAVEMENT OR STRUCTURAL FILL. TRENCH BACKFILL AND COMPAC77ON SHALL BE
COMPLETED PRIOR TO 7E577NG LINES FOR LEAKAGE.
22. ALL SIDE SEWERS SHALL BE A MINIMUM 6" DIAMETER AND HAVE A MINIMUM SLOPE OF
2.0.E PROPERTY/LOT CORNERS AND/OR BUILDING LOC4770NS AND FINISH GRADES SHALL
BE ESTABLISHED IN THE FIELD PR/OR TO ANY SEWER CONSTRUCTION. SIDE SEWER TFE
STA 77ONS ARE REFERENCED FROM THE NEAREST DOWNSTREAM MANHOLE. THE
CONTRACTOR SHALL MAINTAIN ACCURA 7F AS-BUIL T RECORDS OF ALL SIDE SEWER
LOCA 77ONS. ALL SIDE SEWERS SHALL BE IFSIFD AT THE TIME OF MAIN LINE TESTTNG.
PIPE MATERIAL SHALL BE C900 FOR DEPTHS OVER 15''
23 WHERE A W47FR MAIN CROSSES ABOVE lHE SANITARY SEWER, AND LESS THAN 3'O" OF
VERTICAL CLEARANCE EXISTS BETWEEN lHE TOP OF SEWER AND BOTTOM OF W47FR MAIN,
THE SEWER SHALL BE CONSTRUCTED OR RECON57PUCTD WITH DUC77LE IRON PIPE
(CLASS 50) FOR A MIN/MUM HORIZONTAL DISTANCE OF 10' ON EACH SIDE OF THE WA 751?
MAIN CROSSING
24. SANITARY SEWER MAIN LINES (8" DIAMETER AND LARGER) SHALL NOT BE CONS7RUCIFD
ANY CZ OSER THAN 10 FEET TO ANY BUILDING OR 5 FEFT TO ANY CARPORT.
25. NEW CONNECIONS TO EX/STING FACIL177ES SHALL BE SEALED OFF UN77L UPSTREAM
CONSTRUC7ON /S FIN/SHED, TESTED, CLEANED AND ACCEPTED. ALL CONSTRUCTION
DEBRIS AND WATER SHALL BE REMOVED PRIOR TO OPENING THE SEAL. ALL IES77NG
SHALL BE /N THE PRESENCE OF A C/TY OF RENTON INSPECTOR. 26. PR/OR TO
ACCEPTANCE OF CONSTRUCTION AND/OR ISSUANCE OF OCCUPANCY PERMITS,
ENGINEER/SURVEYOR-CER17FIED AS-BUIL T DRAWINGS MUST BE PREPARED OF ALL
SANITARY SEWER FACILITIES
27. INSTALL FALL RE57RAINT SYSTEM /N ALL SANITARY SEVER MANHOLES OVER 20 FEET
DEEP. FALL RESTRAINT SYSTEM SHALL BE "SURETRACT CLIMBING AND FALL PR07FC77ON
SYSTEM" AS MANUFACTURED BY "MILLER FALL P1?OIFC770N"
1: 5 MIX
CONCRETE
BLOCKING 25
MIN
TFE WITH 6" SIDE OUTLET
CLEANOUT=SEE
DETAIL LEFT
2 "x 4 " STUD SER VICE MARKER PAINT UPPER
PORTION WHITE AND LA8EL "SEWER" WITH
3" HIGH BLACK LETTERS. WRAP 16 WIRE
AROUND THE PIPE, EXTEND IT TO FINISH
GRADE AND ATTACH IT TO THE 2 X4" STUD.
SIDE SEWER DETAIL 4
NO SCALE
" SQUARES SPACED - 3/4"
AND/GATED - HT. 1/8"
RA/SE--112"
WIDE BORDER
10"
9"
518,.
2-7/8"
CAST IRON RING AND COVER
ZZWOTE.-
IN UNIMPROVED AREAS POUR 1'-0" THICK 2'-0" SQUARE CONCRETE, CLASS
3000, PAD AROUND RING AND COVER. IN ASPHAL T ROADWA KS RESTORE
AROUND aEANOUT RING AND COVER AS REQUIRED BY STANDARD DETAIL
DRA WING BR36.
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PIPE.
6" SIDE OU7LET TEE
SEWER MAIN
CONCRETE BLOCKING ANGLE
zt
`O OF TEE A T MAIN OVER 25'
0�
t
ANGLE WI EKING
MANGREi B
GO_2X MIN SLOPE
HORIZONTAL
L�SEWER MAIN
TYPICAL SIDE SEWER ELEVA 77ON
NOTE.
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MIN/MUM
ERTY LINE OR J-5" LOWER THAN THE LOWEST HOUSE
4' COVER AT PROP
ELEVA 770N, WHICHEVER /S L OW£R.
UNLESS OTHERWSE APPROVED BY THE CITY, MAKE TAP THROUGH CAST
IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS 57FEL BANDS
WHEN CONNECTING NEW S/DE SEWERS TO EX/S77NG MAIN.
VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D./ PIPE AND C.1.
PIPE SEWER MAINS ARE TO BE CORE DRILLED
SIDE SEWER DETAIL-/
NO SCALE
PIPE MA TER/AL AS SPEC/FIFO
BY THE ENGINEER
6 INCH OR 8 INCH CLEAN -OUT
NO SCALE
CONCRETE
CLASS 3000
3/4 "
11 1 PLUG TO BE SEALED
-�} IN SAME MANNER AS
MAIN SEWER JOINTS.
-------,�
MORTAI
FILLET
MANHOLE FRAME AND CORER
SEE DRAWING BR29
ADJUSTMENT (4' M/N.)
CONE
RUBBER GASKE7ED JOINTS
/N ACCORDANCE WITH ASTM C-443
STEPS - 3/4 " DEFORMED BAR
S7FPS SHALL 8E INCLUDED
CONCRETE R/SER BY PIPE INC.,
OR APPROVED EQUAL.
MAX. PIPE SIZE - 21 m 1. D.
LADDER -STD. ALUM/NUM
OR GAL VAN/ZED S7FEL
CONCREIF SHELF
PRECAST BASE SEC77ON
OR CAST IN SHELF.
NOTES*
1. STEPS TO BE J14" 0 DEFORMED BAR GAL VAN/ZED SAFETY
STEPS OR EQUAL.
2. S7FPS ARE TO BE /N PLACE BEFORE MANHOLE SEC77ONS
ARE INSTALLED.
3 CAS77NG TO BE PER DRAWING BR29.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST
CONCRETE
5. ALL JOINTS SHALL BE GROUTED.
6. SANITARY SEWER MANHOLES SHALL HA VE ALL /N7ER/OR
SURFACES, INCLUDING CHANNELING, CQ47FD (SEALED)
WITH A HIGH SOLIDS URETHANE COATING,'
WA55ER MC-CONSEAL OR APPROVED EQUAL;
COLOR OF COA77NG SHALL BE WH17F
7. RUBBER GASKETFD ✓0/NT5 SHALL BE /N CONFORMANCE
WITH AS7M C-449
8. CHANNEL HEIGHT SHALL BE A MIN/MUM OF J14 THE INSIDE
DIAMETER OF THE LARGEST P/PE.
9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK
ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL.
SANITARYMANHOLE TYPICAL DETAIL
UNDERGROUND LOCATOR SERVICE
CALL BEFORE YOU DIG.
1-800- 424-5555
NO SCALE
S 3410O2
H. STr
fsS�ONAL E�'\
RECOMMENDED
FOR APPROVAL
BY DA7F /-, L
BY DA 7F-
BY. DATE°
1477 1 NE 29th Place Suite 101
Bellevue, Washington 98007
'CO, 425.885.7877 Fax 425.885.7963
DESIGN
ENGINEERING • PLANNING SURVEYING
C0 S-341wAt
COREJOB# 06124
SANITARY SENFR NOIFS & DETAILS C5.31