Loading...
HomeMy WebLinkAboutTED4003417.16+s 3 m Q I ti NOTES: 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS- INC. No. 3705 (LOCKING) OR EQUAL. 2. FRAME AND COVER SHALL BE A WATER TIGHT ASSEMBLY. 3. USF FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). SATEREVISION BY APPR'[ MORTAR FILLET SPECIFY LETTERIN MANHOLE FRAME AND COVER ADOPTED CITY OF RENTON ,.'�■- STANDARD PLANS Nf' tit LST DATE: 04/04 DWG. NAME:B074 SP PAGE-B074 MANHOLE FRAME AND COVER SEE DRAWING BR29 (SP PAGE B074) ADJUSTMENT (4" MIN.) CONE RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 STEPS - 3/4" DEFORMED BAR STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL. MAX. PIPE SIZE - 'E' LADDER -STD. ALUMINUM OR GALVANI7ED STEEL CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. SANITARY MANHOLE TYPICAL DETAIL_ NOT TO SCALE A' 'B' 'C' D' 48" MH 48" 6" MIN. 5"MIN 24 MIN. 21 D. 54" MH 54" 8" MIN. 5.5" MIN. 24" MIN. 24" I.D. 60" MH 60" 8" MIN. 1 6" MIN. 42" MIN. 30" I.D. NOTES: 1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING TO BE PER DRAWING BR29. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. ALL JOINTS SHALL BE GROUTED, 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. B. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE, SANITARY MANHOLE 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL TYPICAL DETAIL 10, MANHOLES EQUAL TO AND GREATER THAN 20 FEET DEEP SHALL HAVE A "SURETRACK" CLIMBING AND FALL PROTECTION SYSTEM INSTALLED. 11 ADOPTED ;� CITY OF RENTON ♦' l♦ STANDARD PLANS _ EST DATE. 04/04 04 10 0 Revised notes. DMC 0 17 96 Added notes. __-_- AG DWG. NAME: DATE I NIFOSION BY APPR'D B071 SP PAGE: B071 .c ao � Q) r.ir4 �Q O L � Q) m Q ,C Z), 6 N 0 Il'o 1 z 0 _ g�a CL J E 0 QL Of Y N 0 C) p_ LL 2 J I () p W CO O Y N = O < N NJ U < a3: z C) � Ow BLUELINE N I. W ® 2007 THE BLUELINE GROUP N J. �� of W Q f � f C 32126 <v SS/ONAL__ I E� EXPIRES: 5/5/08 FOR SLOT DETAIL SEE STD DETAIL DWG D-7 341720 AS-Esc LEVELING PAD (8) 1/8"X 3/4'X 2 1/4" 2 1 /2- 23 3/4" + 5/B" NOTES: I. USE WITH FRAME DRILLED AND TAPPED FOR LOCKING BOLTS. 2. USE WITH TWO LOCKING BOLTS 5/8"-11 NO STAINLESS STEEL TYPE 304 STEEL SOCKET HEAD (ALLEN HEAD) BOLTS, 2" LONG. 3. COVER MATERIAL IS CAST IRON PER ASTM A48 CLASS 30. 4. SHALL CONFROM TO SEC. 7.05 OF THE STANDARD SPECIFICATIONS. 5. COVER SHALL HAVE THE WORD 'DRAIN" IN 2-INCH RAISED LETTERS. $6 BARS AT r SPACING 2Q` 24' DIAM . 46" DW1,. OR s4° aAM HOLE r (TYI'.) j I- 1r , I 1° MIN, 2 12" MAX. 94" OR 96" FLAT SLAB TOP e� �i i 4z) Y5 BARS AT8SPACING 20" x 24"DLAM. 48"Di s OR 54" Douai HaE 111 MIN 7Y" FLAT SLAB TOP 2D- a 24" OR - 24" ID AM. HOLE a° 94 BARS AT 6` SPACING ( T Y P.) I. MIN. 2 112" MAX, 48", 54" or 60" FLAT SLAB TOP 17 3/4" SURFACE WATER UTILITY SOLID LOCKING COVER ADOPTED CITY OF RENTON STANDARD PLANS LST DATE:04/04 DWG. NAME: 3020 SP PACE:B020 TYPICAL_ ORIENTATION FOR ACCESS AND STEPS 2�MiINNN. 4r MIN. . ECCENTRIC CONE SECTION LEVEL PADS (16) 3/4"X 2 1/4"X 1, 25" _I CEMENT CONCRETE CURB GUTTER 31" CATCH BASIN VERTICAL CURB WALL EXTRUDED CURB 7702, CUTTER PLAN CATCH BASIN WALL EXTRUDEDURB 18%24" r~ 9/16" 1 1/2" 1 (+1/32 -0" TYP) - -- 1 4„ �- 17 3 24%23 3/4" (+1/3-0" TYP) 25"x31" ELEVATION NOTES: 1. DRILL AND TAP FOR, AND PROVIDE, TWO LOCKING BOLTS 5/8"-11 NC STAINLESS TYPE 304 STEEL SOCKET HEAD (ALLEN HEAD) BOLTS, 2" LONG. 2. FRAME MATERIAL IS CAST IRON PER ASTM A48 CLASS 30 OR BETTER. 3. SET FRAME TO GRADE AND CONTRUCT ROAD AND GUTTER TO BE FLUSH WITH FRAME. 4. FRAME IS OLYMPIC FOUNDRY #SM50 OR EQUAL. NOTE As an accepiabie aitemate to rebar, wire mesh having a minimum area of 0,12 square inches per foot may be used for adjustment seatians. 1r MIN. u 1 STEP li 12" (TYP.} I 127 PREFABRICATED LADDER 6 OR tr �v i \, ONE 93 BAR HOOP FOR S' TIMD #3 BAR HOOPS FOR 14" RECTANGULAR ADJUSTMENT SECTION �t7 � 15568 13 'L �'r/DNAL EXP4tES JLi.V lI, 2DOL� MISCELLANEOUS DETAILS FOR (MANHOLES AND ONE r3 BAR HOOP -' CATCH BASINS STANDARD PLAN B-1 z SHEET 1 OF 1 SHEER CIRCULAR ADJUSTMENT SECTION - - APPROVED FOR PUBLICATION - Harold J. Peterleso 06-23-04 ADOPTED CITY OF RENTON STANDARD PLANS ? O? LAST DATE: 06/23/2004 SP PAGE B034 SURFACE WATER UTILITY CATCH BASIN FRAME & GRATE DETAILS (SHEET 2 OF 2) p ADOPTED ' ♦ -fir f CITY OF RENTON STANDARD PLANS LST DATE.04/04 DWG. NAME: B020-2 SP PAGE: B020.2 #3 BAR EACH CORNEF 18" MIN #3 BAR HOOP 1 1/4- FOUNDARY NAME 1/2" LETTERS RECESSED TO BE FLUSH Di _E� ao S1 .T10d DN _r Ntl3tlL5 O1 lltl. TOP VIEW 23 3/4" 7/16" 1/16' R=7 1/4" 1 3/8" 1 3/4" 7/8" 3/4 23 1/2" SIDE VIEW 2- -LEVELING PADS 8 - 3/4"X 1 3/4"X 1/8" O� L 3/4" 1 /r' 5/B" SLOT DETAIL -7 1/4" FOR MACHINING BAR 1" THICK TYP. 4 PLACES 3/4"' 7 1/4" 1 3/4" - BARS 1 5/8" THICK THIS AREA BARS 1 3/8" THICK THIS AREA I z' END VIEW 7/11" TYP. SLOT ROUND ELLIPTICAL TANGENT BETWEEN TWO RADII OPTIONAL DESIGN FOR GRATE OPENING ENDS NOTES: 1. SLOT FORMED AND RECESSED FOR 5/8"-11 INC X 2" SOCKET HEAD (ALLEN HEAD) BOLT. 2. GRATE SHALL BE DUCTILE IRON. 3. SHALL CONFORM TO SEC. 9-05.15 OF THE STANDARD SPECIFICATIONS. 4. USE VANED GRATE IN CURB LINE. 5. USE FRAME SHOWN IN STANDARD DETAIL D-7. 6. GRATE IS OLYMPIC FOUNDRY #SM50G OR EQUAL. SURFACE WATER UTILITY CATCH BASIN FRAME & GRATE DETAILS (SHEET 1 OF 2) r ADOPTED �- CITY OF RENTON STANDARD PLANS LST DATE: 04/04 --__bnncinnl Qv n000'n DWG. NAME: B320-1 SP PAGE: B02C.1 \Y ji FRAME AND VANED GRATE / Ap 6" OR 12" ONE #3 BAR HOOP FOR 6" TWO #3 BAR HOOPS FOR 12" RECTANGULAR ADJUSTMENT SECTION PRECAST BASE SECTION NOTES 1, AS AN ACCEPTABLE ALTERNATE TO REBAR. WARE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAYBE USED. WIRE MESH SHALL NOT BE PLACED IN KNOCKOUTS. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20", KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1 5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE, AFTER THE PIPE IS INSTALLED FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT SHALL BE 5'. 4. FRAME AND GRATE MAY BE INSTALLED WITH FLANGE DOWN OR CAST INTO ADJUSTMENT SECTION. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR AND THE WALLS MAY BE SLOPED AT A RATE OF 1:24 OR STEEPER. 6, OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. PIPE ALLOWANCES MAXIMUM PIPE MATERIAL I INSIDE DIAMETER REINFORCED OR I PLAIN CONCRETE ALL METAL PIPE 15" CPSSP * 12" (STD, SPEC. 8-05.20) --------------- SOLID WALL PVC 15" (STD. SPEC 9-05.12(1)) PROFILE WALL PVC 15„ (STD. SPEC. 9-05.12(2)) ��� f45,y1'E� m AONAL 1 rE%P#4€.s Jay i, 2AO51 * CORRUGATED POLYETHYLENE CATCH BASIN TYPE 1 STORM SEWER PIPE STANDARD PLAN 8-1 SHEET 1 OF I SHEET uPROVEa FaR PuauCATtrxi {-Harold J. Pet OT-29-03 ------ ADOPTED ";d " CITY OF RENTON STANDARD PLANS ��' LAST DATE: 07121/2003 SP PAGE B012