Loading...
HomeMy WebLinkAboutWWP2703421.3F_ F_ z I- o O O Z I lii o I:i 3 ri w y V V IL ' CL V w T�� O P4 V1 W 0 W ;Z r—`1 L V = z ZNO F1-D� F� W 0r Z In 0 C I� Lj N O � M � w w In 0 N O UJ cl a Q Y W a O0 3 U Fi CL c W J U V) I m a tt C C v a- rn m L'-1 �\ O,M O m o-- O Z Z O_ Q U � Q 6- z �o o j N x x J J Z Z x tn w U ,I Z o ZU N zo w8w e a�IN w a � In }w} w W :3 N (Z7 w o Z 3 0 Y U 0 O s a Q Q < 0- O W O N 0 X cq A N O m O V) LLJ Z J LLJ O ZQ 04 Z O O z O Z J � rn N O M U W Ld w O Q Q > o w F- F- Ice. W W W ct w U w w w kIx000 a z ul O TEMPORARY 2" GALVANIZED PIPE AND 2" GATE VALVE FINISHED GRADE ELEVATION INSTALL 2" PLUG ON TOP BLIND FLANGE 3 FT MIN. COVER (10-INCH DIAMETER AND UNDER) AFTER REMOVAL OF POLYNG 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) NEW WATER MAIN POLYPIG 1 VERTICAL CROSS FOR POLYPIGGING STATION: SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VERTICAL CROSS (MJ X FL) ONE BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW -OFF ASSEMBLY (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING "POLY -PIG') ONE SUND FLANGE ON BOTTOM OF CROSS ONE PLUG (MJ) ON END OF CROSS CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN WATER MAIN POLYPIGGING STATION VERTICAL CROSS FOR POLYPIGGING TY G\ CITY OF RENTON STANDARD PLANS LST DATE: 04/O4 _ DWG. NAME: 8114 SP PAGE: B114 I DATE I REVISION I BY APpR p FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPER CENTURION 200, AND WATEROUS PACER WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING, TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY-MOORE/PRESERVATIVE PAINT NO. 5780-563 DTM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL, PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT, FIRE HYDRANT EXTENSION TO ` BE USED IF REQUIRED. 18'. TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF SIDEWALK THAT IS ADJACENT TO CURB TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. i EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8' TOP SECTION 4.875 x 5' STORZ WITH REGULAR BASE SECTION LENGTH TO FIT. VALVE NUT o / EXTENSION AS REQUIRED (SEE DWG BR46 / PAGE B090). MIN 2"1 RAISED PAVEMENT MARKER TYPE 88 ` AS STIMSONITE TWO-WAY BLUE. 42 MIN CONCRETE BLOCKING BURY U \ \ '—MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET. `6- GATE VALVE (FL X MJ) AWW.A C-509. RESILIENT SEAT •_6" DUCTILE IRON PIPE. CLASS 52 CEMENT LINED, LENGTH TO FIT 16" x 8` z 4" lNUM 2-3/4" COR-TENSTEEL TIE RODS. SEE STD DETAIL FOR TIE RODS, CONCRETE BLOCK UNDER HYDRANT -1/2 YARD WASHED DRAIN ROCK (3-TO 3/8") MIN. 1' ABOVE BOOT FLANGE. PLACE 8 MIL POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. FIRE HYDRANT ASSEMBLY LEVEL ALL GROUND MIN 3' RADIUS LEVEL ALL GROUND / MIN 3' RADIUS 1 4.875"x5" O6 1 1 STORZ ONE MAN ROCK 6 FILL CUT HYDRANT LOCATION IN CUT OR FILL FIRE HYDRANT ASSEMBLY DETAIL ADOPTED CITY OF RENTON ♦ n <4 4 STANDARDPLANS O LST DATE:04/04 DATE REVISION BY APPR D DWG. NAME: 8102 SP PAGE: 8102 AS -BUILT WATER AND SANITARY SEWER DE I AILS SW 1/4 SECTION 18, TWP. 23 N., RGE. 5 E., W.M. PRECAST CONCRETE VAULT WITH 3 - }'x 3' ONE EACH SIDE 4'x 2 1/2' FIRE DEPARTMENT DOUBLE HINGED STEEL PLATE COVERS. DIMENSION$ 5'-8". 11'-2"x 7'-2" EQUAL TO UTILITY R_4" ADAPTER. RSCREWED CONNECTION FOR STAND PIPE WITH BREAKABLE CAST IRON HOSE CAPS. VAULT OR EQUAL 4".4'.6" BULL HEAD TEE, FL. ONE EACH SIDE EQUAL TO GRINNEL FIG. 1682 PATH HOSE CAPS FIG. 1333. TOUCH READ PIT LID OR SENS MOUNTED ON STEEL PLATE 6' PIPE FL.. FL. 6" SWING TYPE GRAVITY OPERATED COVER THROUGH 1-5/8" DIA. 2'-0" LONG CHECK VALVE, Fl. EQUAL TO GRILLED HOLE IN COVER. MUELLER CO. A-2600-6 WITH BALL GRIP VALVE AT BOTTOM THE BY-PASS ASSEMBLY SHALL BE INCLUDED AS PART OF THE DETECTOR DOUBLE CHECK VALVE ASSEMBLY. \ 18" FOR 10' ASSEMBLY 17 1/2" FOR B" ASSEMBLY INSTALL EPDXY NON -SHRINK OUT (TYP.) 5/8`x3/4. SENSUS SRII (TR/PL) METER 18 1/2; FOR 6" ASSEMBLY }-D 6" PIPE, FL. FL. SO" LONG I 'r1i �I II �v r yr �p�i��❑ rR���ylriil�/111011�i�11����' 6 & 8 ASSEMBLY. 6 SHORT RADIUS 90' BEND R. 10" ASSEMBLY 90- 8'%6- REDUCING BEND R. 10 61ALOINO DEADMAN BLOCK REGUIRE0. 10',8",6"'FL . MJ ADAPTOR ALL DETECTOR DOUBLE UDECR VALVE WITH OR 6' Fl.z P.E. SEATEDASSEMBSHUTOFF SHALL INCLUDE RESIDENT PIPE N1TN COLLAR 18- SEATED SHUTOFF VALVES AND TEST PLAN 10" ASSEMBLY 10"x10"x TEE, L. COCKS AND APPROVED L. FROM PE. 6' ASSEMBLY B"x8"xtE TEE FL. 6" CROSS -CONNECTION CONTROL -6" LONG ASSEMBLY 6'x6'v6" LEE. R. ASSEMBLIES PER DEPARTMENT OF 8 3-6` LONG HEALTH LATEST APPROVED LIST. 10'. 8'. OR 6' GATE VALVE, FLxMJ, 6"- 4' 0" LONG PATH INDICATOR POST. INDICATOR DOUBLE CHECK VALVE ASSEMBLY. POST VALVE SAME SIZE AS DOUBLE INCLUDES TWO RESILIENT SEATED CHECK VALVE (MUELLER CO. OR SHUTOFF VALVES EQUAL). 10", 8 OR 6' FLANGED COUPLING ADAPTER EQUAL TO ROMAC. CLASS B'. OR 6' DUCTILE IRON CLASS 52 NIPPLE PIPE. TOUCH READ PIT LIO SENSOR MOUNTED CEMENT CANED, LENGTH 70 FIT. ON STEEL PLATE COVER THROUGH 1-5/8' DIA. DRILLED HOLE IN COVER. 3 36"TO 42' 6" PIPE FL SCREW 18" FOR 10" ASSEMBLY 17 1/2' FOR 8" ASSEMBLY 18 1/2' FOR 6" ASSEMBLY 2'-6" 3• 2.' 5/8".3/4" INVENSYS TR-PL METER 6' MIN. DRAIN TO DAYLIGHT OR STOR DRAIN SYSTEM WITH 2•-I".. 6' 90' BEND FL GTCH BASIN OR MANHOLE GALVANIZED STEEL LADDER COMPACTED FOUNDATION END VIEW NOTE: GRAVEL AD.A)STABLE STEEL PIPE SUPPORT, STANCHIONS BOLTED TO FLOOR. 1. LOCATE VAULT IN PLANTING AREA, NOT IN PAVING. 2. 4' AND LARGER BENDS AND TEES TO BE CAST IRON CEMENT LINED. 3. TEMPORARY SUPPORT SHALL BE PROVIDED UNDER VALVES AT THE TIME OF INSTALLATION TO CENTER THE .PIPE IN VAULT OPENING. AFTER - COMPLETE INSTALLATION REMOVE THE TEMPORARY SUPPORT AND 10", 8" &. 6" DDCY ASSEMBLY INSTALL ADJUSTABLE PIPE SUPPORT. 4, INSTALL GALVANIZED LADDER FOR ACCESS. 6" STANDPIPE W/4 2-1/2" NOZZLE 5, AFTER FIELD INSTALLATION, MAIN DOCVA AND BY-PASS OCVA MUST BE CROSS C C ONNELION/HACKFLOW TESTED SATISFACTORILY BY A DEPT. OF HEALTH CERTIFIED SACKFLOW PROTECTION ASSEMBLY ASSEMBLY TESTER. TEST REPORT TO BE SUBMITTED TO CITY OF RENTON 1 ADOPTED. WATER UTILITY ENGINEERING DEPT. PRIOR TO ACTIVATION OF NEW LINE. CITY OF RENTON A 6. INSTALL BRASS PLUGS AT ALL TEST COCKS O ! STANDARD PLANS 1. •, V 1S7 DATE: 04/04 - DATE REVISION BY APPR DWG. NAME: 8099 . SP PAGE.8099 RECESSED LIFT POCKET s . 11 11 � 12 Y4" 1 4" I 1 Y" I 1 h 12 14" - CAST IRON RING NOTES 1. B" CLEANOUTS SHALL BE EASE JORDAN IRON WORKS, INC. Np. 3698 OR EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. 2. IN UNIMPROVED AREAS. POUR A 1'-O" THICK, 2'-O' SQUARE CONCRETE. CLASS 3000, PAD AROUND THE RING AND COVER. 4. IN ASPHALT ROADWAYS. RESTORE AROUND CLEANOUT RING AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36. CLASS 1 2 TIGHT I 8 OR 6 INCH CLEANOUT p ADOPTED CITY OF RENTON STANDARD PLANS DWG. NAME:B076-1 1ST DATE: 03/2005 SP PAGE:B076.1 EXISTING WATER LINE PLAN VIEW TESTING DETAIL m8 FT I� O NEW WATER :LINE VERTICAL CROSS(MJxFL) FOR POLYPIGGING ONE BLIND FLANGE ON TOP WITH 2'TAP 6 2'PLUG ONE BLIND FLANGE ON BOTTOM ONE (MJ) PLUG WITH 2' TAP 6 2' TEMPORARY BLOW -OFF TEMPORARY BLOCK CUT -IN (BY CITY FORCES) TEE (FLxFU W/ CONC. BLOCK 3- GATE VALVES (FLxMJ) 2- SOLID SLEEVES (MJ) OR RD-MAC COUPLINGS I- PLUG <MJ) W/2'TAP 6 TEMP, BLOW -OFF TEMP. BLOCK EXISTING WATER LINE EXISTING WATER LINE FINAL CONNECTION DETAIL AFTER ALL TESTING, CLEANING BY POLYPIG, AND DISINFECTION; - REMOVE TEMP. BLOCK 6 BLOW -OFF 6 CONNECT WITH SLEEVE (MJ) 6 D.I. SPOOLS FINAL CONNECTION BY CITY FORCES XISTING WATER LINE WATER CONNECTION DETAIL 3 VALVES CUT -IN INSTALLATION Gl O� CITY OF RENTON a y STANDARD PLANS .TO LST DATE! 04/04 REVISION I BY 16—rIl DWG. NAME: 8112 SP PAGE:6112 PE A MI ROPE AWAY STATIO: DISCHA OPTIONS: ❑ D H 15 2 - 9 3 LEVEIRDCON ROILS) ❑ D R�� 2 — 9 3 LEVEL'CONTROLS) R I @ NSF co CONCRETE BALLAST MAY BE REQUIRED SEE INSTALLATION INSTRUCTIONS FOR DETAILS BLLUW SIRELI GRADE 6" ON 6" Y BRANCH 24"x 24" COMM. CLS. CONCRETE I I BLOCK POURED AROUND I I LONG 6" 1/8 BEND CONNECTION TO MAIN I I 1 STANDARD 6" X MAIN SIZE TEE 45 /- SEWER MAIN NOTE: DO NOT USE WITHOUT WRITTEN APPROVAL OF THE WASTEWATER UTILITY. NOTE: TO RAISE TO GRADE USE STANDARD 6" SEWER PIPE SIDE SEWER RISER CONNECTION TO SEWER MAIN \TY 0 ADOPTED C17Y OF RENTON j 1 ,�- STANDARD PLANS N'LO LST DATE: 04/04 GATE REVISION BY APPR DWG. NAME: 8081 _ - SP PAGE' 8081 DUPLEX ALTERNATING PANEL T -260 EXTERNAL VISUAL & AUDIBLE ALARI EXTERNAL LATCHING MANUAL SILENC MANUAL RUN PUMP RUN INDICATORS CONFORMAL COATED CIRCUIT BOARD PADLOCK ALARM DRY CONTACT NEMA 4X ENCLOSURE ASSEMBLY CORROSION PROOF THERMOPLASTIC POLYESTER APPROVED BY UL FOR ELECTRICAL CONTROL ENCLOSURE OPTIONS: HOUR METER �1 ALARM LIGKT 6 p f KI R OPTIONAL HOUR METERS J WP3 WP4 p �14 wP1 TWyP2 91Pw y wm1 wru Puo n.v Imill ORY CaNAR6 fill GROUND NO BAR LEGEND SERVICE PUMP 1 PUMP 2 FROM CORE 1 1 1 1 I I I 1 1 I I I I I I -- SUPPLY CABLE -I SEENCE LA INSTALLED Ai -FACTORY TALLED ALARM AO 5M 05-02-07 B I N/A PIN FUNCTION 2000S EXTREME 1 MANUAL_RUN RED 2 _ LI BLACK 3 L2 WHITE ABLACK GND GREEN S ALARM FEED ORANGE YELLOW 6 ALARM RETURN BLUE BLUE / eSHE A112.3.4 CE I "'I G+ �/.•:r/�.�: 1:11111115, 5 1 X - 60 IL "RNA ING PANEL, CONTROL CABLE: 240V 6OHz DOUBLE POLE POWER WIRED LEVEL CONTROL TYPE TC1 DIRECT BURIAL, 12AWG, SIX CONDUCTOR LIUS209 I- M 0 0 0 3 2 9 P 1 LISTED 509D OPTIONS: ❑ D H 0 2 LEVELRCCO CONTROLS) FIELD JOINT REQUIRED FOR MODELS DH152-129/ DR152-129 ❑ D R 1 5 2 (WIRELESS LEVEL CONTROLS) DH152-160 / DR152-160 ACCESS WAY VENT GASKETED LID, FRP STRAIN RELIEF CORD DUAL WALL, CORRUGATED CONNECTOR HDPE ACCESSWAY POWER & ALARM CABLE 12-6 W/GND INTERNAL WELL VENT E/ONE EQUALIZE 2.0" DIA. ELECTRICAL QUICK DISCONNECT YDISCHARGE NEMA 6P (EQD) INLET, GROMMET 1 1/4' FPT TO ACCEPT 4.50' O.D.(304 S.S.) PVC PIPE (STANDARD), DUST COVER SUPPLIED ICK DISCONNECT ASSY. FOR SHIPMENT (NOT (304 S.S.) SUITABLE FOR BURIAL) S.S. CAST BALL VALVE 1 1/4" DISCHARGE LINE (304 S.S.) Bin 17mm CHECK VALVE SCH (NORYL) ALARM 3L5in rip, ANTI -SIPHON VALVE 800mm (NORYL) 28.5in ON 724mm OFF 1069a1 401 L 20.5in 16.51n 521mm 420mm 74 9W 58 901 HDPE TANK 280 L 220 L 1/2" NOMINAL WALL THICKNESS 150 GALLON CAPACITY V� NSF CIP SEMI -POSITIVE DISPLACEMENT TYPE PUMP AD CH 07/13/07 A EACH DIRECTLY DRIVEN BY A 1 HP MOTOR DR BY CHK'D DATE SSUE SCALE CONCRETE BALLAST MAY BE REQUIRED Is SEE INSTALLATION INSTRUCTIONS FOR DETAILS SEWER SYSTEMS MODEL DH152 / DR152 DETAIL SHEET NA0052P02 PER AS -BUILT REVISIONS 11-12-2008 24661 � �� F F�l STE��' ��, Lss��NA L E��\ 1i/1,8)08 S-342104 CITY OF RENTON DEPARTMENT OF PUBLI W 3 -D v 3 m I 00 d- N N w O) X Z 0 J m LJ- W Of X I N v U 0- 0) LCJ I� 00 O N N E N v Ql 3 N W Z I m Q I Co CT) N (n O / 00 d- N rn O O 0 N / D_ I.i o AS -BUILT WATER AND m z SANITARY SEWER DETAILS z m 0 O 2�0 Q. = � DESIGNED MCG DATE 7/15/07 FILE NO. O GAT//�G �c�• DRAWN MCC EN G,N�G�' CHECKED AS SCALE AS SHOWN FIELD BOOK PAGE W APPROVED DIRECTOR OF PUBLIC WORKS SHEET 6 \.J m ' f fffppp /�OF