HomeMy WebLinkAboutSWP2703430.22z 6" 48"
00
co
SDR-35 PVC COUPLING
CAST INTO PRECAST BOX WALL
(OUTLET PIPE LOCATION VARIES)
6"
1
SHAPE INLET
j I TO CURB
CLEANOUT
CURB
I I
TOP VIEW
CLEANOUT
COVER
RECESSED TREE FRAME AND CASTIN
GRATE CAST IN TOP SLAB TOP SLAB
8" TOP SLAB
INTERLOCKING JOINT (TYP) --�
I
0
CD
u7 w
MULCH
UNDERDRAIN STONE
1
r
to
GALVANIZED
ANGLE NOSING
CURB AND GUTTER
� F STREET
DOWEL BARS
@ 12" 0. C.
FILTER MEDIA
PERFORATED
UNDERDRAIN SYSTEM
4' x 4' FILTERRA STANDARD PRECAST UNIT
N TS
GALVANIZED ANGLE NOSING
THROAT OPENING
CURB AND GUTTER
FLOW LINE
THROAT ELEVATION
CAST -IN -PLACE
DEPRESSED GUTTER
AND THROAT OPENING
(BY CONTRACTOR)
#4 DOLL BARS ® 12" O.C.
TO BE BENT AS NECESSARY BY CONTRACTOR
PRIOR TO INSTALLATION OF FIELD POURED GUTTER
PRECAST BOX WALL
FILTERRA THROAT OPENING
N TS
USE REMAINING
OUTLET PIPE
KNOCKOUTS FOR TREE
IRRIGATION AS REQUIRED
4'-8.25" TRANSITION TO
DEPRESSED GUTTER
(SEE DETAIL)
OUTLET PIPE CONNECT 4"
PVC (PRECAST IN FILTERRA
UNIT) TO 8" CPEP WITH 8"
4"X8" PVC REDUCER AND
PVC X CPEP COUPLING. //
PRECAST
TOP SLAB
and
\-IN I
THROAT PROTECTION DEVICE
INCLUDED IN PRECAST UNIT
DO NOT REMOVE. LEAVE IN
L, PLACE UNTIL. SITE IS STABILIZED
AND FILTERRA UNIT IS ACTIVATED
A
TWO (2) - 22.5' BENDS
CONNECT 8" CPEP TO
BYPASS STRUCTURE
THROAT (ENTRANCE) \\— 4'-8.25» TRANSITION TO
ELEVATION FROM -
CENTER OF STRUCTURE DEPRESSED GUTTER
AT FLOW LINE. (SEE DETAIL)
FILTERRA UNITS
FOR WATER
QUALITY
FILTERRA
TREE
BOX UNIT
BYPASS
STRUCTURE
STRUCTURE ID
STATION/OFFSET 1
SIZE
THROAT ELEVATION
OUTLET
ELEVATION 1
STRUCTURE ID
STATION/OFFSET
RIM
INLET
ELEVATION
200
28+73.80 (51.8'
L)
4'
X 4'
22.68'
IE 19.85
(N) 4" PVC
42
28+86.16, (47.6'
L)
22.77'
IE 19.30
(W) 8" CPEP
201
30+32.27 (48.1'
L)
4'
X 4'
20.95'
IE 18.10
(N) 4" PVC
40
30+61 9r „ 44.1'
L
20.61'
IE 17.26
W ' C
202
34+83.39 (46.0'
R)
4'
X 4'
25.72'
IE 22.89
IE 23.2£.
(S) 4" PVC
4" PVC
86
768.44.
9, (42.1'
142:?'
R)
I.
5.65'
1'
IE 22.63
8" CF
203
34+82.45 (46.0' L)
4' X 4'
26.05'
IE 21.80
(W) 8" CPEP
1. STATION/OFFSET PROVIDED ARE TO THE CENTER OF THE STRUCTURE
FILTERRA LAYOUT VIEW AND SCHEDULE
N TS
Imc
CLIENTS � PEOPLE 1 PERFORMANCE
753 9th Avenue N
2562 Jefferson Avenue
Seattle. WA 98109
Tacoma, WA 98402
t 206 286-1640
253 627.0720
1201 Third Avenue. Suite 1500, Seattle WA 98101 USA
)
T 1 206 441 9335 F 1 205 448 6922
wwwIpg.com
E seamail@ghd.corn W www.ghd.com
CITY OF RENTON
rJl
Public Works Departrn:-pit
APP*ODFOR CONSTRUCTION
BY: DATE: 111Ie-
-110 18. 51-�-i----
4
DEPRESSED GUTTER CROSS-SECTION
N TS
'r^n. nr ^I Inn r111 Trnn A I I►IIT
%" PREMOLDED
JOINT FILLER (TYP.}
C'� rr,""ESSED GU - "rr'-NSITION
N TS
D M343022