HomeMy WebLinkAboutSWP2703430.22z 6" 48" 00 co SDR-35 PVC COUPLING CAST INTO PRECAST BOX WALL (OUTLET PIPE LOCATION VARIES) 6" 1 SHAPE INLET j I TO CURB CLEANOUT CURB I I TOP VIEW CLEANOUT COVER RECESSED TREE FRAME AND CASTIN GRATE CAST IN TOP SLAB TOP SLAB 8" TOP SLAB INTERLOCKING JOINT (TYP) --� I 0 CD u7 w MULCH UNDERDRAIN STONE 1 r to GALVANIZED ANGLE NOSING CURB AND GUTTER � F STREET DOWEL BARS @ 12" 0. C. FILTER MEDIA PERFORATED UNDERDRAIN SYSTEM 4' x 4' FILTERRA STANDARD PRECAST UNIT N TS GALVANIZED ANGLE NOSING THROAT OPENING CURB AND GUTTER FLOW LINE THROAT ELEVATION CAST -IN -PLACE DEPRESSED GUTTER AND THROAT OPENING (BY CONTRACTOR) #4 DOLL BARS ® 12" O.C. TO BE BENT AS NECESSARY BY CONTRACTOR PRIOR TO INSTALLATION OF FIELD POURED GUTTER PRECAST BOX WALL FILTERRA THROAT OPENING N TS USE REMAINING OUTLET PIPE KNOCKOUTS FOR TREE IRRIGATION AS REQUIRED 4'-8.25" TRANSITION TO DEPRESSED GUTTER (SEE DETAIL) OUTLET PIPE CONNECT 4" PVC (PRECAST IN FILTERRA UNIT) TO 8" CPEP WITH 8" 4"X8" PVC REDUCER AND PVC X CPEP COUPLING. // PRECAST TOP SLAB and \-IN I THROAT PROTECTION DEVICE INCLUDED IN PRECAST UNIT DO NOT REMOVE. LEAVE IN L, PLACE UNTIL. SITE IS STABILIZED AND FILTERRA UNIT IS ACTIVATED A TWO (2) - 22.5' BENDS CONNECT 8" CPEP TO BYPASS STRUCTURE THROAT (ENTRANCE) \\— 4'-8.25» TRANSITION TO ELEVATION FROM - CENTER OF STRUCTURE DEPRESSED GUTTER AT FLOW LINE. (SEE DETAIL) FILTERRA UNITS FOR WATER QUALITY FILTERRA TREE BOX UNIT BYPASS STRUCTURE STRUCTURE ID STATION/OFFSET 1 SIZE THROAT ELEVATION OUTLET ELEVATION 1 STRUCTURE ID STATION/OFFSET RIM INLET ELEVATION 200 28+73.80 (51.8' L) 4' X 4' 22.68' IE 19.85 (N) 4" PVC 42 28+86.16, (47.6' L) 22.77' IE 19.30 (W) 8" CPEP 201 30+32.27 (48.1' L) 4' X 4' 20.95' IE 18.10 (N) 4" PVC 40 30+61 9r „ 44.1' L 20.61' IE 17.26 W ' C 202 34+83.39 (46.0' R) 4' X 4' 25.72' IE 22.89 IE 23.2£. (S) 4" PVC 4" PVC 86 768.44. 9, (42.1' 142:?' R) I. 5.65' 1' IE 22.63 8" CF 203 34+82.45 (46.0' L) 4' X 4' 26.05' IE 21.80 (W) 8" CPEP 1. STATION/OFFSET PROVIDED ARE TO THE CENTER OF THE STRUCTURE FILTERRA LAYOUT VIEW AND SCHEDULE N TS Imc CLIENTS � PEOPLE 1 PERFORMANCE 753 9th Avenue N 2562 Jefferson Avenue Seattle. WA 98109 Tacoma, WA 98402 t 206 286-1640 253 627.0720 1201 Third Avenue. Suite 1500, Seattle WA 98101 USA ) T 1 206 441 9335 F 1 205 448 6922 wwwIpg.com E seamail@ghd.corn W www.ghd.com CITY OF RENTON rJl Public Works Departrn:-pit APP*ODFOR CONSTRUCTION BY: DATE: 111Ie- -110 18. 51-�-i---- 4 DEPRESSED GUTTER CROSS-SECTION N TS 'r^n. nr ^I Inn r111 Trnn A I I►IIT %" PREMOLDED JOINT FILLER (TYP.} C'� rr,""ESSED GU - "rr'-NSITION N TS D M343022