Loading...
HomeMy WebLinkAboutSWP2703430.9CT) y [h GENERAL DRAINAGE NOTES: r .. _ I 1. PIPES LABELED "CPEP" SHALL BE CORRUGATED POLYETHYLENE STORM SEWER PIPE. '— — — — - - - I DIAMOND2. PIPES LABELED "DIP" SHALL BE DUCTILE IRON STORM :EWER 1 �- 51Lp LIDS CASINO FIRESTONE PIPE. i -----------13 AL TOR!� "CPES21 4 3 * L S M DRAINAGE PIPE SHALL HAVE WATERTIGHT JOINTS. 12_ ! _ _ T - 4. CATCH BASINS SHALL BE OF THE TYPE LABELED ON THE PLAN OR -- - —�T. _ J �� -``_ PROFILE, CONFORMING TO THE FOLLOWING STANDARD PLANS: 2" a. TYPE 1 - RENTON STD. PLAN 200.00 12 CPEP �'mom= b. TYPE 1L - RENTON STD. PLAN 200.10 1 H()6 C. CONCRETE INLET - RENTON STD. PLAN 200.30 8 d. TYPE 2 - RENTON STD. PLAN 201.00 r-- g I 109 8 I I $ 107 5. CATCH BASINS SHALL BE CONSTRUCTED WITH OPEN CURB FACE 4 3 II 9 8 r� I I 108 FRAME RENTON STD. PLAN 203,00 AND VANED GRATE w § ,, � } (RENTON STD. II F, PLAN 204,20) UNLESS NOTED OTHERWISE ON THE PLAN OR PROFILE 4 w AS FOLLOWS: o �---- " o a. STANDARD RECTANGULAR FRAME - RENTON STD. PLAN 204.00 +� l ! o b. BI-DIRECTIONAL VANED GRATE - RENTON STD. PLAN 204.30 CN 00 I 43 0 ' — `- r= 44t 00 4 �+ c. RECTANGULAR SOLID METAL COVER - RENTON STD. PLAN 204.10 -� d. ROUND FRAME AND COVER - RENTON STD. PLAN 204.50 RAINIER AVE S ! 6. STATION/OFFSET LOCATION CALLOUTS AND RIM ELEVATIONS PROVIDED �J § 102 ! ! Z ARE FOR THE CENTER OF THE DRAINAGE STRUCTURE. J 8 4 8 100 8 99 = 7. SEE DRAWING NO. 129 FOR TYPICAL PIPE TRENCH CROSS SECTION F— U —� � T _--- — — — — — — — --- --— R•-- " aS 8. DRAINAGE STRUCTURE AND PIPE REMOVALS PAID FOR BY REMOVAL _ - OF STRUCTURE AND OBSTRUCTION t i2"r 4 12" CPEP 12" CPEP 12" CPEP 9. EXISTING STORM DRAINAGE PIPES AND STRUCTURES SHALL BE _.gym M 777-- s _ ABANDONED AND FILLED WHERE INDICATED ON THE PLANS IN _ 82 ACCORDANCE WITH SECTION 2-02.3 4 OF THE SPECIAL PROVISIONS `. 12 CPEP } r�T (FOR PIPES) AND SECTION 7-05.3(2) OF THE STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS FOR STRUCTURES/ CPF�P` h 12" CPEP ( }. DRAINAGE CONSTRUCTION NOTES: (D CONNECT EXISTING PIPE TO NEW CATCH BASIN OR MANHOLE 0 CONNECT NEW PIPE TO EXISTING CATCH BASIN OR MANHOLE � REMOVE u ARM DRAIN PIPE (SEE GENERAL NOTE 8) 04 REMOVE STORM DRAIN STRUCTURE (SEE GENERAL NOTE 8) �5 ADJUST EXISTING RIM TO GRADE V ABANDON AND FILL STORM DRAIN PIPE 0 ABANDON AND FILL STORM DRAIN STRUCTURE I NUMBER REVISION DESCRIPTION DRAINAGE STRUCTURE NOTES: X SEE PROFILE SHEET 123 FOR DRAINAGE STRUCTURE AND PIPE INFORMATION F75] SEE DETAIL -SHEET 127 FOR CONNECTING EXISTING STORM DRAIN PIPES TO NEW STRUCTURE - 58 LF TRENCH DRAIN WITH TRAFFIC RATED GRATE CONNECT TRENCH DRAIN TO OIL WATER SEPARATOR BY TYPE 1 CB OR MANUFACTURER'S EQUIVALENT SEE DETAIL, SHEET 129 [3570 OIL WATER SEPARATOR, 4' X 6' WITH COALESCING PLATE - SEE DETAIL, SHEET 129 ♦' R_ S�1 ♦ C'Jr SURVEYED: KPG DRAWN BY: WRE DESIGN BY: _WRE_ CHECK BY: KRS PROJ VGR: JF- FILE : 0655DSTRN101.dwg ME 4Q n IM CLIENTS PEOPLE PERFORMANCE 753 9th Avenue N 2502 Jefferson Avenue Seattle, VVA 98109 Tacoma, DNA 984C2 200 2�� ��4 } 1201 Third Avenue. Suite 1500, Seattle WA 98101 USA (253) 627.072D T 1 206 441 9335 F 1 205 "8 6922 tww.! g.com E searnail a@ghd,com W www.ghd.com �-- CITY OF RENTON ..tl Public Works C'eprat-tment APPROVED FOR CONSTRUCTION m DATE: //1i►14 10. STRUCTURE(S) TO BE PRIVATELY MAINTAINED BY PROPERTY OWNER (STRUCTURE NO.): 75, 82, 96, 350, 508, 513, 514, 521 CORRESPONDING SHEETS CATEGORY I SHEET RIGHT OF WAY PLANS EXISTING CONDITIONS I 15 I 63 SITE PREPARATION & TESC PLAN 77 ALIGNMENT PLAN 89 ALIGNMENT PROFILE 101 DRAINAGE PLAN 112 DRAINAGE PROFILE 123 WATER PLAN 140 WATER PROFILE 154 JOINT UTILITY TRENCH PLAN 172 JOINT UTILITY TRENCH PROFILES 188 PROPERTY RFSTORATION PLANS f 203 f CHANNEI IZATryON & SIGNING PLAN I ILLUMINATION PLAN 225 236 ' IRRIGATION PLAN 290 LANDSCAPE PLANe `- �! 302 w 1 0 5 10 20 40 60 SCALE IN FEET RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST STA 42+00 TO STA 45+00 D=343009 BID DRAWING NO. 1 12 - PROJECT NO. TED403430 FED AID NO. -CM0167(048) DATE: NOV 2011 SHEET NO, -112- OF_304 m m CA CA cn o N d