HomeMy WebLinkAboutTRO4103430.101a N O cn 'J N 0 Ln L; GO Ln 0 z 0 z w rr cn c� I �- NOTE 2" CONDUIT UNLESS STATED OTHERWISE ON PLANS 1 Y8" DIA TOLE, TYP STEEL PLATE BOLT CIRCLE (DIA SIZE TO LUMINAIRE BASE ANCHOR BOLT PLATE DIMENSION) TEMPLATE ANCHOR 1" DIA, 1'— 6" MIN BELOW GROUND, 2'-0" MIN UNDER PAVEMENT EXTEND THE CONDUIT 6" MIN BEYOND THE FOUNDATION OR THE CONTROLLED DENSITY w U N TOP OF BACKFILL FOUNDATION #4 HOOP, TYP ANCHOR BOLT. 4 TOTAL 1" DIA, TYP #7, TYP ANCHOR BOLT TEMPLATE, TYP 2 1 /2" CLR 1" HEX NUTS, STEEL, rill 4 REQ'D PER ANCHOR BOLT FIAT WASHERS, _ 4 REQ'D PER ANCHOR BOLT N ANCHOR BOLT ASSEMBLY NUMBER EDGE OF SHOULDER UNDISTURBED SOIL TYP �I LIGHT STANDARD FOUNDATION ' 36» EIGHT #7 BARS, EVENLY SPACED CENTER THE CONDUIT IN THE FOUNDATION 1'-3" DIA BOLT CIRCLE, TYP T , HOOP, TYP TOP VIEW FIXED BASE Y4" CHAMFER, TYP 1 z I� Q N a_ 2z z w o � � z 0 O � 0 Q O o z z o SECTION VIEW FIXED BASE 1. SEE WSDOT STANDARD PLAN J-28.40 FOR LUMINAIRE POLE BASE MOUNTING DETAILS, EXCEPT USE 4-BOLT PATTERN. 2. THE STRAP TEMPLATES SHALL BE HELD IN PLACE BY NUTS, 6" FROM THE TOP OF THE FOUNDATION AND 3" FROM THE BOTTOM OF THE ANCHOR BOLTS. 18 HEAVY DUTY HEX NUTS AND 6 PLATE WASHERS ARE REQUIRED FOR A FIXED BASE ASSEMBLY. 3. THIS DESIGN IS NOT VALID FOR SLOPES STEEPER THAN 2H:1V. SLOPES STEEPER THAN THIS SHALL REQUIRE A SPECIAL DESIGN. 4. THE LUMINAIRE POLE HEIGHT SHALL NOT EXCEED 50' (H1). 5. FOUNDATIONS CONSTRUCTED WITHIN ECOLOGY EMBANKMENTS SHALL BE INCREASED IN DEPTH BY THE DEPTH OF THE ECOLOGY EMBANKMENT. 6. EXPOSED PORTIONS OF THE FOUNDATION SHALL BE FORMED TO CREATE A CLASS 2 SURFACE FINISH. ALL FORMING SHALL BE REMOVED UPON COMPLETION FOUNDATION CONSTRUCTION. 7. FOR CASING OPTIONS, SEE METHOD 1 AND METHOD 2 BELOW. CONTRACTOR SHALL ASSUME THE SPECIAL CONSTRUCTION METHODS SHOWN BELOW FOR THE FOUNDATIONS WILL BE REQUIRED FOR ALL ROADWAY LUMINAIRE AND SIGNAL POLE FOUNDATIONS. 8. THE ANCHOR BOLTS SHALL BE HIGH STRENGTH STEEL, MANUFACTURED FROM ASTM A449, WITH HEAVY HEX NUTS AND HARDENED WASHERS. GALVANIZE THE ANCHOR BOLTS ACCORDING TO AASHTO M232. 9. THE FOUNDATION SHALL BE GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATION SECTION 8-20.3(4). ROADWAY (35 FT) LUMINAIRE POLE FOUNDATION DESIGN DETAIL N TS LUMINAIRE POLE UNDISTURBED SOIL 3'-0" DIA (CASE A SHOWN) DRAWING SOURCE WSDOT STANDARD PLAN J-28.30-01 WITH MODIFICATIONS CONSTRUCTION NOTES 1. THESE FOUNDATION CONSTRUCTION METHODS ARE APPLICABLE TO ALL STEEL LIGHT AND SIGNAL STANDARD PLACEMENT CASES. 2. CONSTRUCTION METHODS FOR POLE FOUNDATIONS TYPICALLY INVOLVE DRILLING A VERTICAL SHAFT WITH A SINGLE -FLIGHT AUGER DRILL RIG, PLACING A REINFORCING STEEL CAGE INTO THE DRILLED HOLE, AND FILLING THE HOLE WITH CONCRETE. 3. TWO METHODS OF CASING REMOVAL ARE OUTLINED BELOW. a. METHOD 1: THE CASING SHOULD BE PULLED OUT AS CONCRETE IS PLACED IN THE HOLE, WHILE A SUFFICIENT HEAD OF CONCRETE IS MAINTAINED INSIDE THE CASING TO PREVENT CAVING AND SLOUGHING OF THE HOLE. b. METHOD 2: THE CASING SHOULD BE PULLED IMMEDIATELY AFTER THE PLACEMENT OF THE CONCRETE, AND THE HOLE IS TOPPED OFF WITH CONCRETE AFTER THE CASING HAS BEEN REMOVED. LUMINAIRE POLE FOUNDATION SPECIAL CONSTRUCTION METHODS DETAIL NITS REVISION DESCRIPTION 1114-11 � crGAN of WAs�r _ z 1P 39324 w� rsTEae �`� �sSIONAL 1 � SURVEYED: KPG DRAWN BY: AMK DESIGN BY: AMK CHECK BY: JC PROJ MGR: JF FILE:0655DILL02.dwg BY APP. DATE 753 9th Avenue N 2502 Jefferson Avenue Seattle; WA 98109 Tacoma, WA 98402 (206) 286-1640 (253) 627-0720 www.kpg.com O z 1= U m � Q cc n a a z CD Of o � J w Q Of ~ w � J n � o � U w z 0 d- CONCRETE CLASS 4000P #5 BAR, TYP EVENLY SPACED 8 N #5 BARS RE—INFORCEMENT DETAILS PEDESTRIAN (14 N TS %" CHAMFER, TYP 2" ELECTRICAL CONDUIT 1 1 /2" 1 Y8" DIA HOLE, TYP ANCHOR BOLT TEMPLATE, TYP ' 1" HEX NUTS, STEEL, a a a a • a 4 REQ'D PER ANCHOR BOLT FL AT WASHERS, a 4 REQ'D PER ANCHOR BOLT a a • • a a • e aQ ANCHOR BOLT DETAILS ANCHOR BOLT TEMPLATE LUMINAIRE POLE FOUNDATION DESIGN DETAIL - CITY OF RENTON BIDPublic Works Department DOCUMENTS APP E,D FOR CONSTRUCTION BY: DATE: I/6 /f Y" STEEL PLATE BOLT CIRCLE (TO BE PROVIDED BY MANUFACTURER) T 3430180 DETAILS BASED ON GEOTECHNICAL REPORT PROVIDED BY JACOBS ASSOCIATES, DATED OCTOBER 2011, FOUND IN THE APPENDICES OF THESE CONTRACT DOCUMENTS I�I RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST ILLUMINATION FOUNDATION DETAILS DRAWING NO. 240 PROJECT NO. TED403430 FED AID NO.-CM016i�u43 � DATE: NOV 2011 SHEET NO. 240 OF 304