Loading...
HomeMy WebLinkAboutTRO4103430.11 (2)CEMENT CONCRETE SIDEWALK SECTION PER TYPICAL SECTIONS AND DETAILS GRAVEL BACKFILL INCL. HAUL FOR JOINT UTILITY TRENCH INCLUDE ILLUMINATION AND SIGNAL CONDUIT IN JOINT TRENCH WHERE POSSIBLE SEE ILLUMINATION AND SIGNAL PLANS. CD N CN 0 Ln Ln z 0 z w / U w 0 ry CEMENT CONCRETE SIDEWALK, DRIVEWAYS, PARKING AND PLANTED AREAS PER TYPICAL SECTIONS, ROADWAY AREAS PER ALIGNMENT PLANS AND PROPERTY TYPICAL SECTIONS AND RESTORATION PLANS ALIGNMENT PLANS I H W � �' C) Z U O Q Z o � o N W ii: U o z a 12" TYP 2" TYP U � C� Ld O� U 12" TYP "STRUCTURE EXCAVATION CLASS B INCL. HAUL FOR JOINT UTILITY TRENCH" MAXIMUM PAY LIMITS = NEAT LINE WIDTH NOTES: INCLUDING SWEEPS 1. TRENCH WIDTH INCREASES AT SWEEP LOCATIONS. 1' MIN FOR TRENCH CROSSINGS No FOR SAWCUT AS INDICATED ON PLANS 2. FINISHED SURFACES OTHER THAN SIDEWALKS AND ROADWAY PAVEMENT NOT SHOWN. PROVIDE ROADWAY CONCRETE, CURBS, DRIVEWAY AND PARKING PAVEMENT, AND UNPAVED SURFACE RESTORATION AS SHOWN ON THE PLANS. 3. TEMPORARY PAVEMENT MAY BE USED IN AREAS WHERE ADDITIONAL ROADWAY OR TRENCH EXCAVATION IS ANTICIPATED, OR WHERE DRIVEWAY OR PEDESTRIAN ACCESS MUST BE MAINTAINED. 4. EXCAVATION AND DISPOSAL OF CONTAMINATED SOILS SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS. SEE SITE PREPARATION AND TESC PLANS, SHEETS 69-79, FOR APPROXIMATE CONTAMINATED SOIL LIMITS. 5. IF UNSUITABLE FOUNDATION IS ENCOUNTERED, SEE DETAIL, SHT 26. TYPICAL JOINT UTILITY TRENCH SECTION N TS A SAND BEDDING a_ R d- 30" MIN COVER OVER CONDUIT BANK C Y Z Q m z 0 U 36" MIN COVER OVER CONDUITS FINISHED GROUND 10 VARIES 12" MIN CLEAR _ \-- EXISTING PAVEMENT DEFLECT JOINTS OR PROVIDE o MAY INCLUDE BURIED FITTINGS/BENDS/SWEEPS AS o o CONCRETE ROADWAY REQUIRED BY THE FRANCHISE U w --j PANELS (TYP) UTILITIES Z => O Q Lr- �>< X ul a- TYPICAL JOINT UTILITY TRENCH TRANSITION Q N TS PROPOSED UTILITY OR EXISTING UTILITY TO REMAIN CONDUITS MINIMUM CASING CONDUIT SIZING AND COLD BENDING RADIUS FOR PE PIPE APPLIES TO BID ITEMS "INSTALL _" DIAMETER CONDUIT-PSE GAS" LINE SIZE (DIA.) CASING CONDUIT SIZE (DIA.) MIN. LONG-TERM BEND RADIUS 2" 4„ 5-011 6" 10" 13,-10" APPROXIMATE EXTENTS OF CONDUIT INSTALLATION FOR PSE GAS APPLIES TO BID ITEMS "INSTALL _" DIAMETER CONDUIT-PSE GAS" APPROXIMATE BEGINNING STATION APPROXIMATE ENDING STATION SIZE CONDUIT IN/OUT DESIGNATION 12+20, 55' LT 22+10, 80' LT 10" 1 g 22+85, 60' LT 23+50, 160' RT 6" 2g 22+10, 80' LT 26+10, 62' LT 4" 3g 34+00, 27' LT 45+75, 60' LT 6" 4g CITY OF RENTON Public Works Department APPROV D FOR CONSTRUCTION % BY: ./l DATE: LOW EAST GUTTER PROFILE OR WEST GUTTER PROFILE AS SHOWN ON JOINT TRENCH PROFILE SHTS. — PLANTER SIDEWALK w o0 oS O Of - CONDUIT BANK LOCATION VARIES NOTES: SEE JOINT UTILITY TRENCH PLANS 1. MAINTAIN 3' MIN COVER FROM FINISHED GRADE SURFACE ABOVE CONDUIT, 2. EAST GUTTER PROFILE AND WEST GUTTER PROFILE IS SHOWN ON JOINT UTILITY TRENCH PROFILE FOR REFERENCE. TYPICAL JOINT UTILITY TRENCH PROFILE COORDINATION N TS T 3430 RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST JOINT UTILITY TRENCH DETAILS