Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TRO4103430.135
C� Ln t0 CD i POLE SCHEDULE STATION OFFSET POLE POLE HEIGHT DIAMETER RAINIER AVE S, 106.9' RT 4'-0" 5.06" STA 10+88.4 RAINIER AVE S, 103.0' RT 4'-6" 5.13" STA 10+89.1 ® RAINIER AVE S, 99.1' RT 2'-11" 4.78" STA 10+90.0 RAINIER AVE S, 95.3' RT 6'-4" 5.39" STA 10+91.3 ® RAINIER AVE S, 91.6' RT 8'-1" 5.63" STA 10+92.8 RAINIER AVE S, 88.1' RT 9'-9" 0 5.87" STA 10+94.7 © RAINIER AVE S, 84.7' RT 11'-4" 6.09" 10+96.8 __.STA r ;R A�1;NIR AV -A ! , 8 , -O„ „ 6.18 i��r �S 04-99.3 I o 1 ' RAINIER AVE S, 78.6 RT 11 -7 „ 6.12 i_/--� ; STA 11 +02.0 O _ RAINIER AVE S, 75.9 RT 10 -1 „ 5.91 STA 11+04.9 i RAINIER AVE S 73.5' RT 7'-0" ' 5.48" STA 11 +08.1 11 ,) l:l RAINIER AVE S, 71.5' RT 4'-7" 5.14" STA 11+11.6 O RAINIER AVE S, 70.6' RT 3'-1" 4.93" STA 11+15.5 O RAINIER AVE S, 71.7' RT 2'-6" 4.85" STA 11+19.3 RAINIER AVE S, 74.5 RT , 3 -2 „ 4.94 STA 11+22.1 d- as WEEP HOLE FOR DRAINAGE TYPICAL POLE POST -TOP DETAIL TOP FLANGE I.D. FLUSH WITH TENON 4Y2" O.D. SCHEDULE 40 ALUMINUM PIPE TENON HOLE (4 AT 90'), TYP. 3/" NTP CLOSED NIPPLE (TO ACCEPT LUMINAIRE PROVIDED BY OTHERS) POST FLANGE (Y" THICK X 6Y" 0) BORE & THREAD CENTER FOR %" NTP WELDING BY POLE MANUFACTURER SEE THIS SHEET FOR POLE DETAILS NOTES: 1. MANUFACTURER TO PROVIDE CLOSED NIPPLE LENGTH WITH SHORTEST NIPPLE LENGTH POSSIBLE. 2. NTP HOLE IN POST FLANGE SHALL BE ON POLE AXIS. 3. NO GASKETS ANYWHERE ON POLE POST -TOP ASSEMBLY. F-- W w Cn Cn w M W c� Cn W I 0 w w w Cn I W Q C.D W LLJ 0 DECORATIVE ART POLE WITH POST -TOP GLOBE DETAIL N TS I NUMBER I REVISION DESCRIPTION PAINT SPECIFICATIONS: ALL METAL POLE PARTS SHALL BE FACTORY PRIMED AND POWDER COAT FINISH COLOR: RAL 7047 "TELEGREY 4" 20 WATT LED LUMININAIRE SHALL BE PROVIDED AND INSTALLED BY OTHERS RISER ASSEMBLY AND DECORATIVE POST -TOP GLOBE SHALL BE INSTALLED BY OTHERS POLE POST TOP & TENON ASSEMBLY SHALL BE FABRICATED AND WELDED BY THE POLE MANUFACTURER. SEE THIS SHEET FOR DETAIL POLE AND BRACKET CABLE INSTALL ALL ASSOCIATED WIRING TAPERED ALUMINUM POLE (0.14"/FT, 0.188" MINIMUM POLE WALL THICKNESS) WITH POLE POST TOP ASSEMBLY. POLE SET VERTICAL AND PLUMB. SEE POLE SCHEDULE FOR POLE HEIGHT AND DIAMETER. FOR CONTINUATION OF LUMINAIRE WIRING, SEE TYPICAL POLE / JUNCTION BOX WIRING DETAIL, THIS SHEET 3-5/8" x 6.5" HANDHOLE WITH REMOVABLE ACCESS COVER AND STAINLESS STEEL SCREWS. ALL HANDHOLES SHALL BE ORIENTED AWAY FROM FACE OF CURB. BASE PLATE EDGES SHALL BE PARALLEL TO THE SIDEWALK SCORING PATTERN FINISH GRADE ! 11-14-11 CTGAA SURVEYED: KPG A� oe WAs�r� DRAWN BY: JHL o DESIGN BY: JHL 39324 �ONAL CHECK BY: JC PROJ MGR: JF BY APP. DATE FILE: Details.dwg 753 9th Avenue N 2502 Jefferson Avenue Seattle, WA 98109 Tacoma, WA 98402 (206) 286-1640 (253) 627 0720 www.kpg.com _ 1" ROUND FORM (TYP) GROUT FLUSH WITH FINISH GRADE (TYP) �- SIDEWALK I r, SEAL WATERTIGHT PER MANUFACTURER'S RECOMMENDATIONS 3-#8 (ONE IS --\ GROUND) SIDE VIEW 3-#8 (ONE IS GROUND) 1 /2" PVC SCH 40 CONDUIT 2-#8 GROUND LUG/ 2-#8 1- #8 SEE GROUNDING (GROUND) � NOTE #� 3-#8 \1 I (ONE IS GROUND) I � d r ° d SEE )GROUNDING N OTE'�3 ° d d. SEE GROUNDING I NOTE #2 3-#8 (ONE IS - GROUND) POLE GROUND WIRING DETAIL SEE ILLUMINATION PLANS FOR CONTINUATION. BID DOCUMENTS 3-#8 WIRING (ONE IS GROUND) GROUNDING ROD (5/8" X 8' LONG) 04 IN -GROUND LED LUMINAIRE DETAIL. N TS SEC MODEL 1791-DP (DOUBLE PIN), OR APPROVED EQUAL JUNCTION BOX TYPE 1. SEE COR STD DWG #JO07 FOR DETAILS NOT SHOWN SEE GROUNDING NOTE #4 IN -GROUND LED LUMINAIRE (3200K CCT) WITH ADJUSTABLE OPTICAL ASSEMBLY AND INTEGRAL DRIVER. INSTALL PER MANUFACIFURER'S INSTRUCTIONS, t°. j i l L OPENINGS FOR CONDUIT ENTRY BOTTOM VIEW T 34302 14 GROUNDING NOTES: 1. USE NON -INSULATED #4 AWG STRANDED COPPER. PROVIDE 3' MINIMUM SLACK ROUTE CONDUCTOR TO THE GROUND LUG. 2. CLAMP CONDUCTOR TO STEEL REINFORCING BAR WITH LISTED CONNECTOR SUITABLE FOR USE EMBEDDED IN CONCRETE. 3. USE NON -INSULATED #4 AWG STRANDED COPPER AND BOND JUMPER WIRE TO RGS CONDUITS. 4. USE NON -INSULATED #4 AWG STRANDED COPPER AND BOND TO RGS CONDUITS, GROUND ROD, AND JUNCTION BOX LID. SEC MODEL 1791-DP (DOUBLE PIN), OR APPROVED EQUAL SEE "POLE GROUND -� WIRING DETAIL" THIS SHEET TYPICAL POLE / JUNCTION BOX WIRING DETAIL (EXCEPT FOR POLE 'C' (WALL A MOUNTED), SEE "DECORATIVE ART POLE 'C' CONDUIT/WIRING AT FOUNDATION DETAIL" SHEET 272 }'- CITY OF R NTON ML Public Works Department APPr/VVD FOR CONSTRUCTION s BY: DATE: zZ x f TO LUMINAIRE (TYP) SEC MODEL 1-791-SFPOLE - (SINGLE FUSED), OR BRACKETD APPROVED EQUAL l CABLE GROUND LUG (TYP) RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST ELECTRICAL DETAILS S GRADY WAY INTERSECTION e, e 4 Lfl e e i 1" RGS CONDUIT (TYP) 3-#8 WIRING (ONE IS GROUND) SEE FOUNDATION DETAIL, SHEET 272 DRAWING NO. _274 --- FED AID NO.-CM0167(04�Si DATE: NOV 2011 SHEET NO. 274 OF 304 m J m�t DO d � C CA N L C7 a