EXISTING NEW DESCRIPTION
ELECTRICAL SERVICE CABINET W F
IN -GROUND LED LUMINAIRE ("SPOT")
Q
JUNCTION BOX TYPE 1, 2 Ll!
Z
0000
SIGNAL/ILLUMINATION JUNCTION BOX
TYP E 1, 2, 8 I
CONDUIT
WIRE NOTE
O CONSTRUCTION NOTE
GENERAL NOTES
1. ALL WORK SHALL BE COMPLETED IN THE ACCORDANCE WITH THE CITY GUIDELINES,
WSDOT/APWA STANDARD PLANS, STANDARD SPECIFICATIONS, LATEST AMENDMENTS TO
THE STANDARD SPECIFICATIONS, SPECIAL PROVISIONS AND THESE PLANS.
2. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE
EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS
EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION
BOXES, AS REQUIRED.
3. THE LOCATION OF ALL CONDUIT, JUNCTION PDXES, AND LUMINAIRES SHOWN ON THIS
PLAN ARF FOR GRAPHIC PRESENTATION ONLY. THE CONTRACTOR SHALL INSTALL
CONDUIT IN THE 'SAME TRENCH AS ILLUMINATION AND SIGNAL CONDUITS WHERE
PRACTICABLE. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND
APPROVED BY THE ENGINEER IN THE FIELD.
WIRE NOTES
RACEWAY/
CONDUIT
CONDUCTORS
COMMENTS
SIZE
1
2"
1 2-#8
NOTES:
1. ALL NEW CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1-#8
GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE
SCHEDULE).
2. ALL NEW CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY
USE RIGID PVC SCH 80.
CONSTRUCTION NOTES
1
_ 1
10�
00
00
00
loo 6
1 �
0,
O FURNISH AND INSTALL IN -GROUND LED LUMINAIRE, CONDUIT/WIRING AND ALL ASSOCIATED EQUIPMENT PER "IN -GROUND LED
LUMINAIRE LAYOUT DETAIL", ELECTRICAL DETAILS SHEET 274. IN -GROUND LED LUMINAIRES SHALL BE FIELD LOCATED IN THE
PRESENCE OF THE ENGINEER AND THE ARTIST. SEE SPECIAL PROVISIONS.
Q FOR CONTINUATION OF CONDUIT/WIRING, SEE SIGNALIZATION PLANS.
L e CA'flON OF POWER SOURCE. SEE ILLUMINATION PLANS FOR CONSTRUCTION NOTE, WIRING AND DETAILS.
IN -GROUND LED LUMINAIRE (TYP)
SEE DETAIL SHEET 274
— IDENTITY COLUMN
I
SEE PLANS FOR
IN -GROUND LED
—
LUMNAIRE LOCATION
TYPICAL IDENTITY COLUMN IN -GROUND LED LUMINAIRE LAYOUT
N TSJ
NUFJ1E;ER�:.�s..p..,��,..�.,. REVISION DESCRIPTION
U' L IN -GROUND LED LUMINAIRE (TYP)
SEE DETAIL SHEET 274
TYPICAL GATEWAY TRELLIS IN --GROUND LED LUMINAIRE LAYOUT
N TS
CIGqN -
11-14-11 SURVEYED: KPG
oF WAsDRAWN BY: JHL
DESIGN BY: ,JHL
CHECK BY: JC
39324
�FcisTER� ��`� PROJ MGR: JF
�I�NA L ECG
BY APP. DATE FILE: Details.dwg
NW CORNER
1
SEE SW CORNER (THIS SHEET) FOR
CONDUIT/WIRING CONTINUATION
C'if K1111 r%nnklrn I-n iir- ni irrr% r--�m
SW CORNER
SEE NW CORNER
(THIS SHEET) FOR
CONDUIT/WIRING
CONTINUATION
SEE NE CORNER
(THIS SHEET) FOR
CONDUIT/WIRING
CONTINUATION
A
I V.
IVC VVrx1Nr_M
SEE NE CORNER (THIS SHEET) FOR
CONDUIT/WIRING CONTINUATION
i
JCL JL UVRNER k i rnJ antt I) r OR
CONDUIT/WIRING CONTINUATION
i
I
1
[MJ14JULLU
1Eb4Cw"14k A16}'- CITY OF RENTON
=�
753 9th Avenue N 2502 Jefferson Avenue BID Public Works Department
Seattle, WA 98109 Tacoma, WA 98402 DOCUMENTS
(206) 286-1640 (253) 627-0720 APPROV D FOR CONSTRUCTION
www.kpg.com BY: DATE:
SE CORNER
RAINIER AVENUE S (SR 167)
S GRADY WAY TO S 2ND ST
ELECTRICAL PLAN AND DETAILS
S 3RD ST INTERSECTION
0 5 10 20 30
SCALE IN FEET
DRAWING No.
2_0_._._
PROJECT NO.
TED403430
FED AID NO.
-CM016 O48)
DATE:
NOV 2011
SHEET NO. 280 OF `014