SYMBOL
MANUFACTURER
MODEL NO.
DESCRIPTION
RAINBIRD
BUBBLER SERIES-1402
FULL —CIRCLE FLOOD BUBBLER — INSTALL PER DETAIL SHEET 293.
EST SST
RAINBIRD
1800-15 STRIP SERIES
SHRUB HEAD — 6" PLASTIC POP—UP. 5'x15', 5'x30' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL
ON FLEXIBLE RISER
® 0
RAINBIRD
1800-15 STRIP SERIES
LAWN HEAD — 6" PLASTIC POP—UP. 5'x15', 5'x3O' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL
ON FLEXIBLE RISER
8Q 8H
RAINBIRD
8 SERIES MPR
SHRUB HEAD — 6" PLASTIC POP—UP. ADJ TO 8' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
k' m m
RAINBIRD
12 SERIES MPR
LAWN HEAD — 6" PLASTIC POP—UP. ADJ TO 12' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
12Q 12H 12F
® �
12Q 12H
RAINBIRD
12 SERIES MPR
SHRUB HEAD — 6" PLASTIC POP—UP. ADJ TO 12' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
C
RAINBIRD
15 SERIES MPR
SHRUB HEAD — 6" PLASTIC POP—UP. 15' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
5Q 15 , ; :F
ra 6L 9
!
15 SERIES MPR
LAWN HEAD — 6" PLASTIC POP—UP. 15' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
I5Q 15H 15FJ�INBIRD
s
SENTINEL SATILLITE
(2) 24—STATION OUTDOOR CONTROLLERS (A & B), STAINLESS STEEL PEDESTAL MOUNTED WITH CONCRETE
IR
(I
TORO
A—SSAK24PS16NS1
FOUNDATION. SEE SIGNAL PLANS FOR ELECTRICAL SERVICE. PROVIDE 3 SPARE WIRES (RED) FROM
CONTROLLER
B—SSAK24PS16NS1
THROUGH EACH CONTROL VALVE BOX, TO FURTHEST VALVE BOX FROM CONTROLLER. PROVIDE TELEPHONE LINE TO
I
CONTROLLERS FOR TELEPHONE MODEM.
®
WEATHERMATIC
2100
AUTOMATIC CONTROL VALVE — SIZE AS NOTED ON PLAN.
POC—A
POINT OF
CONNECTION EQUIPMENT, APPROX.
STA 26+65, 50' RT. SEE DETAILS THIS SHEET AND SHEET 293.
D4
FEBCO
850
1 1/2" DOUBLE CHECK VALVE.
WEATHERMATIC
2100
1 1/2" MASTER SHUTOFF VALVE AND TORO TFS FLOW SENSOR
QO
RAINBIRD
44—LRC
1" BRASS QUICK COUPLER VALVE WITH LOCKING VINYL COVER. INSTALL PER DETAIL. INSTALL ONE AT
DOUBLE CHECK
VALVE ASSEMBLY.
E
1 1/2" IRRIGATION METER. SEE WATER PLANS FOR MORE INFORMATION.
POC—B
POINT OF
CONNECTION EQUIPMENT, APPROX. STA 35+82, 44' LT. SEE DETAILS THIS SHEET AND SHEET 293.
D4
FEBCO
850
1 1/2" DOUBLE CHECK VALVE.
WEATHERMATIC
2100
1 1/2" MASTER SHUTOFF VALVE AND TORO TFS FLOW SENSOR
i
RAINBIRD
44—LRC
1" BRASS QUICK COUPLER VALVE WITH LOCKING VINYL COVER. INSTALL PER DETAIL. INSTALL ONE AT
DOUBLE CHECK
I
VALVE ASSEMBLY.
1 1/2" IRRIGATION METER. SEE WATER PLANS FOR MORE INFORMATION.
— —
PVC SCH 40, IRRIGATION MAIN LINE — 24" MIN COVER
PVC SCH 40, LATERAL SUPPLY LINE— 18" MIN. COVER — SIZE AS NOTED.
—
—
SLEEVING, PVC SCHEDULE 40, SIZE TWICE INSERT PIPE DIA.
1S 1F A
INDICATES VALVE & CONTROLLER # "A" OR "B" INDICATES CONTROLLER A OR B
10.5
INDICATES APPROX. GPM
"is" INDICATES VALVES FOR STREETSCAPE PLANTER ZONES.
INDICATES VALVE SIZE
"1F" INDICATES VALVES FOR FILTERRA/TREE GRATE ZONES.
DOUBLE CHECK VALVE
PRESSURE REDUCING VALVE
POC VALVE BOX IRRIGATION GENERAL NOT' -
QUICK COUPLER
(2) STAINLESS STEEL CLAMPS
TO STAKE
P.V.C. NIPPLE
3' #4 REBAR STAKE
360' PVC TRIPLE SWING JOINT
P.V.C. PRESSURE MAIN
PVC TEE OR ELBOW WITH
SIDE ELEVATION THREADED OUTLET
QUICK COUPLER OR
SPRINKLER BODY
360' PVC TRIPLE SWING JOINT
PVC THREADED TEE AT
MAINLINE
SECTION THROUGH MAIN LINE
QUICK C011PLINC.. VAI VF/ TRIPI F SWIN[...ICIINT
NOTE:
ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS
IPS FEMALE CONNECTION OF QUICK COUPLER/
SPRINKLER HEAD
INSTALL IN DCVA BOX
QUICK COUPLING VALVE,
SEE DETAIL THIS SHEET
ALL FITTINGS PVC
COORDINATE INSTALLATION OF IRRIGATION SYSTEM WITH INSTALLATION OF OTHER
UTILITIES, INCLUDING JOINT TRENCH AND FILTERRA UNITS. LOCATE AND PROTECT
ALL UNDERGROUND UTILITIES DURING INSTALLATION OF IRRIGATION SYSTEM.
IRRIGATION SYSTEM SHALL BE INSTALLED, TESTED, MAINTAINED AND GUARANTEED
AS PER SPECIFICATIONS.
IRRIGATION SYSTEM IS DESIGNED TO OPERATE FROM 30 PSI. CONTRACTOR SHALL
FIELD CHECK EXISTING WATER PRESSURE, ADJUSTING PRV AS NECESSARY TO
PROVIDE OPTIMUM PERFORMANCE.
LOCATIONS OF IRRIGATION MAIN LINE, LATERALS, SLEEVING AND VALVES INDICATED
ON DRAWINGS ARE. SCHEMATIC ONLY. ADJUST LOCATIONS AS NECESSARY. DO
NOT OVERSPRAY ONTO PAVED SURFACES.
IRRIGATION MAIN LINE LOCATION IS DIAGRAMMATIC LINE SHALL BE PLACED IN
PLANTING AREAS V? ?E EVER POSS191 F
MAIN LINE SHALL BE BURIED TO A DEPTH OF 24" BELOW FINISH C' A -DE, LATERAL
LINE FOR SPRAY ZONES SHALL BE BURIED TO A 01EPTH OF 18" BELOW FINISH
GRADE. LATERAL LINE FOR BUBBLER ZONES SHALL BE BURIED TO A DEPTH OF 12"
BELOW FINISH GRADE.
SLEEVE UNDER ALL PAVED SURFACES, CONCRETE SIDEWALK AND BETWEEN FILTERRA
UNITS AND SIDEWALK. SEE IRRIGATION PLANS FOR LOCATION OF PVC SLEEVING,
SLEEVING SHALL BE 2 TIMES THE DIAMETER OF THE INSERT PIPE AND WIRES.
CONTROLLER WIRES SHALL BE TAPED TOGETHER IN A BUNDLE AT 10' INTERVALS.
SNAKE WIRE IN BOTTOM OF PIPE TRENCH WHERE POSSIBLE. WHERE PIPE TRENCH IS
UNAVAILABLE WIRES SHALL BE PLACED IN SLEEVING. WIRES TO CONTROLLER SHALL
BE PLACED IN 1" / 1.5" SLEEVE, USE 3M DBY SPLICE KITS.
ALL EQUIPMENT SHALL BE AS SPECIFIED OR APPROVED EQUAL BY CITY OF RENTON.
SYSTEM IS SPECIFICALLY DESIGNED FOR IRRIGATION EQUIPMENT SHOWN ON PLANS
AND SUBSTITUTION WILL REQUIRE REDESIGN AND RECALCULATION OF IRRIGATION
ZONES.
NO GALVANIZED FITTINGS. ONLY BRASS OR SCH 40 PVC SHALL BE USED.
IRRIGATION TRENCHING NEAR ANY TREES TO REMAIN SHALL BE DONE WITH THE
MINIMUM AMOUNT OF DISTURBANCE POSSIBLE. TRIM AND CUT CLEAN ANY EXPOSED
OR DAMAGED ROOTS.
STACKED METER BOXES PER CITY OF
RENTON STANDARDS. SIZE TO FIT
EQUIPMENT.
--i �-- COMPACT BACKFILL
APPROVED DOUBLE CHECK VALVE, INSTALL
I —I i PER CITY OF RENTON STANDARDS.
PRESSURE REDUCING
VALVE
SHUT OFF VALVE AND FLOW SHUT OFF VALVE �-
IN SEPARATE VALVE BOX
PVC IRRIGATION MAIN ,
RIGATION METER ° ° o a ° a° o°° °o° °� ° o ° ° s o04 0..O0 O°o:00 °° . 0
°° °°�O 'o.o: o.0 0 .o .°° ° �0 . °0 0 0 O ° o
0
0 • ° ° °
Lz TO PRESSURE MAIN ° ° ° ° 0 ° Q° ° 0 °0 8" MIN DEPTH PEA
° ° .0 ° ° ° GRAVEL, WITH FILTER
NOTE: —
— � � �III � FABRIC
CONNECTION TO PRESSURE MAIN SHALL NOT BE
MADE UNTIL IRRIGATION MAIN LINE IS PRESSURE Iy
1" QUICK COUPLER VALVE TESTED. INSTALL ASSEMBLY IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN - 340.8.
SEE POINT OF CONNECTION ASSEMBLY, THIS SHEET.
TYPIrAL POINT OF r' NNE+ TION ASSEMBLY
N 1 ..) - -
NUMBER REVISION
nFTAII nni ]R1 F ('.HF['.K VAI VF ASSFMRI V
PRESSURE MAIN CONNECT
TO MASTER SHUT OFF
VALVE (INSTALLED IN
SEPARATE BOX)
T=3430232
V� t�O�U
o Z Q
Cn-�W '
N 5
�3�v�i
o
Q
J
11-14-11
0
°vl_
~
a
Q~
of
U
SURVEYED: KPG
DRAWN BY: EM
DESIGN BY: EM
CHECK BY: EG
PROJ MGR: JF
FILE:0655DIRR01.dwg
Kp�
R
753 9th Avenue N 2502 Jefferson Avenue "' I D
Seattle, WA 98109 Tacoma, WA 98402
(206)286-1640 (253)627-0720 DOCUMENTS
www.kpg.com
�'- CITY OF R +NTON
�,
—
Public Works Department
APP VED FOR CONSTRUCTION
BY: DATE;/ /-1i
RAINIER AVENUE S (SR 167)
S GRADY WAY TO S 2ND ST
IRRIGATION SCHEDULE AND DETAILS
DRAWING NO. 292
PROJECT NO. TED403430
FED AID NO.-CM0167(048)
DATE: NOV 2011
SHEET NO. 292 OF 304
APP.
DATE
11F