HomeMy WebLinkAboutTRO4103430.2 (2)0 CN N 0 Ln Ln co CD W41 VAULT SCHEDULE PLAN 0 5 10 20 40 60 SCAL-E IN FEET ID P3 VAULT THREE PHASE J—BOX FRANCHISE UTILITY ID J06 OWNED BY PSE PROVIDED BY PSE INSTALLED BY CONTRACTOR CONDUIT IN/FROM LEFT 1p,3p CONDUIT OUT/TO RIGHT 5p,6p,1-4" Q3 264 TA #915 CENTURYLINK CENTURYLINK CONTRACTOR 2q,3q 4q,5q,1-4" C39 2436 MEDIUM DUTY VAULT — COMCAST COMCAST CONTRACTOR 3c,4c 5c,6c,1—Y P31 INTERCEPT POINT IP01 PSE — CONTRACTOR 1-4" — Q4 264 TA #914 CENTURYLINK CENTURYLINK CONTRACTOR — 1-4" P57 REMOVE VAULT J05 PSE — CONTRACTOR — — P58 REMOVE VAULT J07 PSE — CONTRACTOR — — 11-14-11 SURVEYED: KPG ti4� GIA COS DRAWN BY: SOD �o DESIGN BY: SOD ' 20320 CHECK BY: JLF w� .�� �FGrsTF. f�NAL ECG � PROJ MGR: JF � NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DJUT01.dwg C161 753 9th Avenue N 2502 Jefferson Avenue Seattle, WA 98109 Tacoma, WA 98402 (206) 286-1640 (253) 627.0720 www,kpg.com EXISTING UNDERGROUND UTILITIES TO BE CONVERTED TO NEW UNDERGROUND ALIGNMENT TO THE LIMITS SHOWN. CONTRACTOR SHALL PROVIDE ALL NECESSARY COORDINATION, LAYOUT, SURVEYING, TRENCHING, EXCAVATION, BEDDING, BACKFILL AND RESTORATION FOR THE FRANCHISE UTILITIES TO SUCCESSFULLY COMPLETE THE CONVERSION. THE LAYOUT SHOWN IS APPROXIMATE AND A COMPILATION OF THE DESIGNS BY PSE, COMCAST, CENTURYLINK, AND CITY OF RENTON. SEE FRANCHISE UTILITY PLANS (VOLUME 4 OF 4) FOR DESIGNS BY PSE POWER, PSE GAS, COMCAST, AND CENTURYLINK. 2. THE JOINT TRENCH LAYOUT, SWEEPS, VAULTS AND OTHER FEATURES SHOWN ARE APPROXIMATE. ADJUST AS NECESSARY TO MEET FRANCHISE UTILITY REQUIREMENTS AND TO PROVIDE A COMPLETE, FUNCTIONING SYSTEM. ALL CONDUIT MATERIALS, BENDS, VAULTS, AND OTHER MATERIALS INSTALLED BY THE CONTRACTOR SHALL BE PER THE REQUIREMENTS AND SPECIFICATIONS OF THE FRANCHISE UTILITIES, 3. PSE WILL FURNISH ALL VAULTS AND CONDUITS REQUIRED FOR THEIR ELECTRICAL_ CONVERSION. PSE WILL FURNISH ALL CASING CONDUIT REQUIRED FOR THEIR GAS CONVERSION. 4. THE CONTRACTOR WILL FURNISH AND INSTALL ALL VAULTS AND CONDUITS FOR THE CITY OF RENTON. 5. COMCAST AND CENTURYLINK WILL FURNISH ALL VAULTS AND CONDUITS REQUIRED FOR THEIR CONVERSION. 6. UNDERGROUND SERVICE CONNECTIONS FOR CENTURYLINK AND COMCAST SHALL BE MADE BY THE FRANCHISE UTILITIES. 7. UNDERGROUND SERVICE CONNECTIONS FOR POWER SHALL BE MADE BY THE PROPERTY OWNER FROM THE RIGHT—OF—WAY TO EXISTING PRIVATE METERS. 8. CONSTRUCT JOINT UTILITY TRENCH PER THE TYPICAL TRENCH DETAILS, SECTIONS AND PROFILE SHEETS 174-192. ADJUST THE HORIZONTAL ALIGNMENT AND VERTICAL PROFILE AS NECESSARY TO AVOID CONFLICTS WITH EXISTING AND PROPOSED UTILITIES AND ROADWAY FEATURES, WHILE MAINTAINING 3' MINIMUM COVER OVER CONDUITS AND VERTICAL 12" MINIMUM CLEAR BETWEEN OTHER UNDERGROUND UTILITIES. THE CONTRACTOR SHALL VERTICALLY TRANSITION THE TRENCH DEPTH BY DEFLECTING JOINTS OR INSTALLING BENDS PER THE. FR ANC IISE, UTILITY REQUIREMENTS. SEE 'THE APPROXIMATE' JOINT UTILITY TRENCH PROFILE TO AID IN THE LAYOUT OF THE TRENCH, SHEETS 180-192. 9. CONTRACTOR SHALL SEQUENCE WORK TO ALLOW CONTINUED OPERATION OF ALL EXISTING UTILITIES UNTIL NEW SYSTEM IS COMPLETE. ONCE NEW SYSTEM IS COMPLETED, TESTED, APPROVED BY UTILITY OWNERS AND FULLY OPERATIONAL, CONTRACTOR SHALL REMOVE EXISTING CONDUIT DUCT BANK AND EXISTING UTILITY STRUCTURES NO LONGER IN USE. 10 INCLUDE ILLUMINATION AND SIGNAL CONDUIT IN JOINT TRENCH WHERE POSSIBLE. SEE ILLUMINATION AND SIGNAL PLANS FOR CITY OF RENTON POWER AND FIBER DESIGN. 11. CONTRACTOR TO INSTALL CENTURYLINK OVERSET VAULTS. 12. CONTRACTOR SHALL PRESERVE AND PROTECT ALL FACILITIES TO REMAIN. CONSTRUCTION NOTES A2 4" DIAMETER CONDUIT—CENTURYLINK (1 CONDUIT) ABEGIN INSTALLATION OF 10" DIAMETER CONDUIT—PSE GAS — APPROXIMATE STA 12+20, LT JOINT UTILITY TRENCH LEGEND FOR JOINT UTILITY TRENCH LEGEND, SEE SHT 164. CITY OF RENTON BID Public Works Department DOCUMENTS APPROVE FOR CONSTRUCTION BY -- � DATE:: CATEGORY SHEET RIGHT OF WAY PLANS 8 _ _ EXISTING CONDITIONS 56---� SITE PREPARATION & TESC PLAN 70 ALIGNMENT PLAN 82 ALIGNMENT PROFILE 94 DRAINAGE PLANS 105 DRAINAGE PROFILE 114,115 V1fATER PLAN 133 WATER PROFILE 147 JOINT UTILITY TRENCH PLAN — JOINT UTILITY TRENCH PROFILES 181 PROPERTY RESTORATION PLANS 196 CHANNELIZATION & SIGNING PLAN 218 ILLUMINATION PLANS 229 IRRIGATION PLAN 283 LANDSCAPE PLAN 295 RAINIER AVENUE S (SR 157) S GRADY WAY TO S 2ND ST JOINT UTILITY TRENCH PLAN STA 12+00 TO STA 15+50 DRAWING NO. PROJECT NO. TED403430 FED AID NO.-CM0167 048) DATE: NOV 2011 SHEET NO. 165 OF 304