HomeMy WebLinkAboutTRO4103430.85GENERAL CHANNELIZATION NOTES
CD
N
N
0
N
N
FK
0
Ln
Ln
Q0
CD
z
O
F-
z
w
Cn
v
w
O
-.
b
BLOCKBUSTER b
. --
D24
4
MATCH EXISTING CHANNELIZATION
STA 449+15.00 3.80' RT
STA 449+22.93, 4.45' RT
STA 449+24.75, 17.3 ' T
a
12.8
(S6
r S10
w .:e .:a ::e e:e .:a .:a .:e sae .:e :e .:a ._� .:a .:e .:e .;e .:a .:9 .:e e .:a
.:e .:-
`LI _ 8 RAINIER AVE S STA 40+72.39, 32.91' LT
❑ °
® . • • ° . • ❑ 10 • • • • STA 40+75.06, 21.95' LT
+ r 13 ❑
. ❑ ❑ . ❑._ e.. ❑
- STA 38+713�6, 40 STA 40+70,53,
z 100' R 3.5' LT • a . e .1.12' & 10.88' LT
-� STA 38+54.66, 2.06 LT 4� e ® e e . a
= STA 38+01.44, 7.06' RT STA 39+13.48, 8.5' RT 1 4 STA 40+78.46, 11.0' RT
Iv- ❑ o ❑ .
7 8 4 STA 39+75.02, 31.44' RT STA 40+81.16, 22.04' RT
e:: a:: es: a:: es: e:: e:: e:: e:: e:: ; e e e
STA 40+83.85, 33.08' RT
,
S9
S3
McLENDON
HARDWARE
SIGN SCHEDULE
SIGN
NO.
STATION
OFFSET
DESIGNATION
REMARKS
S1
40+64.39
80.41' LT
"FRED MEYER"
REMAIN
S2
40+79.13
57.72' LT
I R_3-5 "RIGHT TURN ONLY"
REMOVE
I S3
" 38+33.96
59.10 RT
RELOCATE
PARK NGE ONLY"
S4
139+91.32
60.29 RT
"CUSTOMER a,
PARKING ONLY
RELOCATE
I S5
141+_65_._81
RT-
R3-5 "RIGHT TURN ONLY"
REMOVE
'-S6
-�
_52.99'
�LI
R10-30 (MOD)
NEW SIGNAL POLE MOUNT
S7
RT
I R10-30 (MOD)
NEW SIGNAL POLE MOUNT
S8
38+58.34
46.87' LT
"BUS"
BY OTHERS
S9
38+90.53
46.50' RT
R3-7R (MOD)
NEW
S10
38+36.27
46.50' LT
R3-2004 MOD
W
S11
40+93.04
52.50' RT
"MCLENDON HARDWARE"
�REOVED BY OTHERS
NOTE: FOR R3-2004 (MOD) & R3-7R (MOD), SEE SHEET 217.
FOR R10-30 (MOD) DETAILS, SEE SHEET 220.
FOR SIGNAL POLE MOUNTED SIGN DETAILS & LOCATIONS, SEE SIGNALIZATION PLANS.
"M
S4
0 5 10 20 40 60
SCALE IN FEET
S11
STA 41 +01.63,
49.00' RT -
MATCH EXISTING CHANNELIZATION
STA 449+15.00, 8.97' LT
-P
0 18
STA 449+25.60, 8.07' LT
IM
2
STA 449+35.83, 20.56' LT
STA 41 +49.28, 47.35' LT
3 STA 41 +65.94,
S2
34.32' LT
STA 40+77.25,
STA 41 +68.33, 2
50.94' LT
23.36' LT a a .
" J 8
STA 41 +70.73,
12.39' LT
Ln
1 N
STA 40+75.53, STA 41 +79.94, 0�
1.05' LT .54 LT a e LLJ
LJj
41 13 N czn
I CD
rCF71 cv
1211
40
1;
��►
STA 41 �73.34, 0.43' LT ---" \ A "d-
Q
3 tio -� c
STA 41 80.14, 12.54 ' RT - w
z
STA 41+73. 4, 23.44 RT __ e:•
Q
STA 41 +76.35, 7
77
34.48' RT
7� ravi .94w-w w 0 0 w
2
STA 450+65.1 ,�, 15'
19.97' RT 1 6' •••
STA 450+80.951
6.32' RT - -P
18 1
MATCH EXISTING CHANNELIZATION N 4
STA 450+99.29, 8.09' LT & 6.32' RT
O
.0
r
II ST 41+71.84,
5 06' RT
UB SHOP
STA 450+80.18,
23.71' LT
- STA 450+82.82,
8.41' LT
1. REMOVE ALL EXISTING CONFLICTING CHANNELIZATION.
2. ALL PAVEMENT MARKING MATERIAL SHALL CONFORM TO THE "STATE OF
WASHINGTON STANDARD SPECIFICATION FOR ROAD, BRIDGE, AND
MUNICIPAL CONSTRUCTION," LATEST EDITION.
3. FOR CHANNELIZATION AND SIGNING DETAILS, SEE CITY OF REN O
STANDARD PLANS UNLESS OTHERWISE NOTED.
4. PRESERVE AND PROTECT EXISTING SIGNS TO REMAIN.
5. ALL NEW .AND RELOCATED ROADWAY SIGNS T"° 'HAVE NEW PO" AN`"
POST BASES PER CITY OF RENTON S:ANDARD PLAN) G0'04, G010 ANI
G012.
6. FOR REMOVAL AND/OR RELOCATION OF PRIVATE BUSINESS SIGNS AND
OTHER PRIVATE PROPERTY ITEMS, SEE SITE PREPARATION & TESC PLANS,
SHEETS 69 - 80.
CHANNELIZATION NOTES
1❑ WIDE LINE PER WSDOT STD PLAN M-20.50-02.
® 18" PLASTIC STOP LINE PER WSDOT STD PLAN M-24.60-03.
® 12" WHITE PLASTIC CROSSWALK LINE PER CROSSWALK LINE AND STOP
LINE DETAIL, SHEET 25 AND DECORATIVE CROSSWALK TREATMENT
DETAIL, SHT 281.
�4
PLASTIC TRAFFIC ARROW PER WSDOT
STD PLAN
M-24.40-01,
M-3.40-03, M-3.10-03, M-3.50-02
AND M-5.10-02.
WIDE DOTTED LANE LINE PER WSDOT
STD PLAN
M-20.50--02.
®
LANE LINE PER WSDOT STD PLAN M-20.50-02.
10
NO PASS LINE PER WSDOT STD PLAN
M-20.50-02.
13
PAIN! MEDIAN CURB YELLOW.
18
DOUBLE YELLOW CENTER LINE PER WSDOT STD
PLAN M-20.50-02.
T=3430164
CORRESPONDING SHEETS
CATEGORY
SHEET
RIGHT OF WAY PLANS
14
EXISTING CONDITIONS
62
SITE PREPARATION & TESC PLAN 76
ALIGNMENT PLAN i 88
-_
ALIGNMENT PROFILE
100
DRAINAGE PLANS
111
DRAINAGE PROFILE
122
WATER PROFILE
I53
JOINT UTILITY TRENCH PLAN
171
JOINT UTILITY TRENCH PROFILES
187
PROPERTY RESTORATION PLANS
202
CHANNELIZATION & SIGNING PLAN 1
=
ILLUMINATION PLANS
235
IRRIGATION PLAN
289
LANDSCAPE PLAN
301
I
AUULNUUM 1Z - JII KLMUVLU isT UIHLKJ.
JUU
I/ - I I I
4,VxG1AC0 11-14-11
wAs�r �y
203�0�0 �wx
SURVEYED: KPG __
DRAWN BY: KMH
DESIGN BY: KMH
CHECK BY: JMD _
PROJ MGR: JF
FILE: 0655DCH01.dwg
3p,�
7539th Avenue N 2502 Jefferson Avenue BID
WA 98402
Seattle, WA Tacoma, DOCUMENTS
(206) 286-1640 (253) 627-0720
www.kpg.com
CITY OF RENTON
Public Works Department
APPROVED FOR CONSTRUCTION
�4$
BY: � DATE: / i /�
RAINIER AVENUE S (SR 167)
S GRADY WAY TO S 2ND ST
CHANNELIZATION & SIGNING PLAN
STA 38+00 TO STA 42+00
DRAWING NO. 224
-- -
PROJECT NO. TED403430
FED AID NO.-CM0167(048)
DATE: NOV 2011
SHEET NO. 224 OF 304
NUMBER
REVISION DESCRIPTION
BY
APP.
DATE