HomeMy WebLinkAboutTRO4103430.90CD
N
N
0
_J
Ln
Ln
QO
0
/
a
0
V
cn
I
/
0
r`
0
M
o
Li
CL 'i1
0
0
N
�CGEND
EXISTING
DENOTES Ex.
POLE DECAL/
XXXX
►t
X7m
NEW DESCRIPTION
SIGNAL POLE WITH MAST ARM
TYPE 1 OR PS POLE
EXISTING LUMINAIRE
DECORATIVE PEDESTRIAN LUMINAIRE
DECORATIVE ROADWAY LUMINAIRE
DECORATIVE PEDESTRIAN/ROADWAY LUMINAI
SIGNAL CONTROLLER CABINET
ELECTRICAL SERVICE CABINET
ITS CABINET
JUNCTION BOX TYPE 1, 2, 8
25—TA VAULT
'CONDUIT
JIT
WIRE NOTE
CONSTRUCTION NOTE
GENERAL NOTES
1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS &
SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE
CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS.
2. UTILITY LOCATION (DIAL —A —DIG) PRIOR TO CONSTRUCTION SHALL BE TF
RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT
TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION.
3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING TF
ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH
PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425)
456-2701 PRIOR TO INSTALLATION OF METER BASE.
4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACT(
SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION
5.. ALL. NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PEF
COR STD PLAN #127.
6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL
LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED
BY THE ENGINEER IN THE FIELD.
7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL).
IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
INSTALL ADDITIONAL JI UNCTION BOXES, AS REQUIRED.
8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN
ACCORDANCE WITH SECTION 8-20.3(1)A OF THE SPECIFICATIONS. THE
CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE
ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE
CONSTRUCTION. COORDINATE WORK WITH THE PLOWER COMPANY
REPRESENTATIVE.
CONSTRUCTION NOTES
9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE
PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW
PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT.
SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO
EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL
VOIDS PER SPECIAL PROVISIONS.
O CONSTRUCT LUMINAIRE POLE
FOUNDATION PER ILLUMINATION DETAILS
SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE,
POLE, ARM, CONDUIT/WIRING
ALL ASSOCIATED EQUIPMENT
AND APPLY
DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL
INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD
DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL
PROVISIONS.
O REMOVE EXISTING LUMINAIRE
POLE, LUMINAIRE, JUNCTION
BOX, WIRING
AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND
DOWN EXISTING FOUNDATION
2' BELOW PROPOSED GRADE.
BACKFILL
AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS.
SALVAGE CITY OWNED POLE
AND LUMINAIRE PER SPECIAL
PROVISIONS.
Q4 EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION.
(D SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT.
10 FOR EXISTING JUNCTION BOX REMOVAL/MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS.
RcMC�VE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING
AND CAP AND ABANDON EXISTING UNUSED CONDUIT.
<1-3> SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING.
ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12-16-11 11-14-11 SURVEYED: KPG
F
o wAsy,,I,S9 DRAWN BY: JM
4 DESIGN BY: JF
CHECK BY: JF
Ox, AFC//6 _ ERA° ��PROJ MGR: TN
-SS/ONAL ENG\
NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DILL01.dwg
0
LUMINAIRE SCHEDULE
(ELECTRICAL SERVICE CABINET "S1" — SEE CIRCUIT AND PANEL SCHEDULES SHEET 238)
TIRE NOTES
RACEWAY/
CONDUIT
SI ZE
CONDUCTORS
COMMENTS
1
2"
2#8
SEE
NOTES
BELOW
2
2"
4#8
6#8
SEE
NOTES
BELOW
3 2"
SEE NOTES
BELOW
4
4"
SPARE
5
6
4"
2
EX.
1-96 SMFO
SEE
NOTES
BELOW
SEE NOTES
SEE NOTES
BELOW
BELOW
7
8
4"
EX. 1-48 SMFO
RE-ROUTE
I
OTES:
ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1-#8
GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE
SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL -LINE
TAPE AND LABELED "CITY OF RENTON".
ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40,
EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT
AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE
FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS.
LUMINAIRE
#
STATION
OFFSET
LUMINAIRE TYPE
LUMINAIRE
ARM
MOUNTING
HEIGHT
POLE
TYPE
CIRCUIT
#
DECAL
#
COMMENTS
4
RAINIER AVE S,
STA
12+04
51.5'
LT
"DECORATIVE"
135W
LED
(M-II-FC)
240V
6'
35'
40'
C
7704NL
SERVICE
#S1
5
RAINIER AVE S,
STA
12+86
53.5'
RT
"DECORATIVE"
135W
LED
(M-II-FC)
240V
6'
35'
40'
C
7703NL
SERVICE
_
#S1
-
6
RAINIER AVE S,
STA
13+14
51.5'
LT
"DECORATIVE"
135W
LED
(M-II-FC)
240V
1 6'
35'
40'
B
7706NL
SERVICE
#S1
7
RAINIER AVE S,
STA
14+00
53.5'
RT
"DECORATIVE"
135W
LED
(M-II-FC)
240V
6'
35'
40'
B
7705NL
SERVICE
#S1 - _ --
8
RAINIER AVE S,
STA
14+41
53.0'
LT
"DECORATIVE"
135W
LED
(M-II-FC)
240V
12'
35'
40'
C
7708N
SERVICE
#S1 -
9
RAINIER AVE S,
STA
15+29
53.5'
RT
"DECORATIVE"
135W
LED
(M-II-FC)
240V
6'
35'
40'
C
7707NL
SERVICE
#S1
P4
SHARED
POLE
"DECORATIVE"
60W
LED
(S-III-FC)
240V
4'
14'
40'
D
7704NL
SERVICE
#S1
_
P5
RAINIER AVE S,
STA
12+23
53.5'
RT
"DECORATIVE"
60W
LED
(S-III-FC)
240V
4'
14'
18'
D
7710L
SERVICE
#S1
P6
RAINIER AVE S,
STA
12+66
51.5'
LT
"DECORATIVE"
60W
LED
(S-III-FC)
240V
4'
14'
18'
D
7709L
SERVICE
#S1
P7
SHARED
POLE
"DECORATIVE"
60W
LED
(S-III-FC)
240V
4
14'
40'
D
7703NL
SERVICE
#S1
P8
SHARED
POLE
"DECORATIVE"
60W
LED
(S-III-FC)
240V
4'
14'
40'
D
7706NL
SERVICE
#S1
P9
RAINIER AVE S,
STA
13+41
53.5'
RT
"DECORATIVE"
60W
LED
(S-III-FC)
240V
4'
14'
18'
D
7711 L
SERVICE
#S1
P10
SHARED
POLE
"DECORATIVE"
60W
LED
(S-III-FC)
240V
4'
14'
40'
D
7705NL
SERVICE
#S1
P11
RAINIER AVE S,
STA
14+65
53.5'
RT
"DECORATIVE"
60W
LED
(S-III-FC)
240V
4'
14
18'
D
7713L
SERVICE
#S1
P12
P13
RAINIER AVE S,
SHARED
STA
POLE
15+35
42.0'
LT
"DECORATIVE"
"DECORATIVE"
60W
60W
LED
LED
(S-III-FC)
S-III-FC
240V
240V
4'
4'
14'
14'
18'
40'
1 D
D
7712L
7707NL
SERVICE
SERVICE
#S1
#S1
f?
FEHR
&L PEERS
TRANSPORTATION CONSULTANTS
1001 4th Avenue.
° Wairct creek. CA ° Orange Canty. CA
° Ros Hle. CA ° Los Angeles Canty. CA
Suite 4120
° Say J_ CA ° Say Dlego, CA
Seattle. WA 98154
° S " FfHfO SM CA ° salt sake City. UT
(206) 576-4220
NV
° S. ttie. tAa CA ° aan. .
° Seettle. wA ° Denier. 00
KPG
753 9th Ave N 2502 Jefferson Ave
Seattle, WA 98109 Tacoma, WA 98402
(206) 286-1640 (253) 627-0720
www.kpg.com
}'- CITY OF RENTON
.J1
Public Works Depertmen.
APPROYyb FOR CONSTRUCTION
BY: DATE:10 r.
3430169
0 5 10 20 40 :'
SCALE IN FEET
RAINIER AVENUE S (SR 167)
S GRADY WAY TO S 2ND ST
ILLUMINATION AND INTERCONNECT PLAN
STA 12+00 TO STA 15+50
BID
OC MEN I
L>RAWING NO.
PROJECT NO. TED403430
FED AID NO. CM0167(048)
DATE: NOV 2011
SHEET NO. 229 OF 304