Loading...
HomeMy WebLinkAboutTRO4103430.90CD N N 0 _J Ln Ln QO 0 / a 0 V cn I / 0 r` 0 M o Li CL 'i1 0 0 N �CGEND EXISTING DENOTES Ex. POLE DECAL/ XXXX ►t X7m NEW DESCRIPTION SIGNAL POLE WITH MAST ARM TYPE 1 OR PS POLE EXISTING LUMINAIRE DECORATIVE PEDESTRIAN LUMINAIRE DECORATIVE ROADWAY LUMINAIRE DECORATIVE PEDESTRIAN/ROADWAY LUMINAI SIGNAL CONTROLLER CABINET ELECTRICAL SERVICE CABINET ITS CABINET JUNCTION BOX TYPE 1, 2, 8 25—TA VAULT 'CONDUIT JIT WIRE NOTE CONSTRUCTION NOTE GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL —A —DIG) PRIOR TO CONSTRUCTION SHALL BE TF RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING TF ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456-2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACT( SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION 5.. ALL. NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PEF COR STD PLAN #127. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JI UNCTION BOXES, AS REQUIRED. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH SECTION 8-20.3(1)A OF THE SPECIFICATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE PLOWER COMPANY REPRESENTATIVE. CONSTRUCTION NOTES 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT/WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. Q4 EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. (D SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT. 10 FOR EXISTING JUNCTION BOX REMOVAL/MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. RcMC�VE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. <1-3> SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12-16-11 11-14-11 SURVEYED: KPG F o wAsy,,I,S9 DRAWN BY: JM 4 DESIGN BY: JF CHECK BY: JF Ox, AFC//6 _ ERA° ��PROJ MGR: TN -SS/ONAL ENG\ NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DILL01.dwg 0 LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S1" — SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) TIRE NOTES RACEWAY/ CONDUIT SI ZE CONDUCTORS COMMENTS 1 2" 2#8 SEE NOTES BELOW 2 2" 4#8 6#8 SEE NOTES BELOW 3 2" SEE NOTES BELOW 4 4" SPARE 5 6 4" 2 EX. 1-96 SMFO SEE NOTES BELOW SEE NOTES SEE NOTES BELOW BELOW 7 8 4" EX. 1-48 SMFO RE-ROUTE I OTES: ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1-#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL -LINE TAPE AND LABELED "CITY OF RENTON". ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. LUMINAIRE # STATION OFFSET LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT POLE TYPE CIRCUIT # DECAL # COMMENTS 4 RAINIER AVE S, STA 12+04 51.5' LT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40' C 7704NL SERVICE #S1 5 RAINIER AVE S, STA 12+86 53.5' RT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40' C 7703NL SERVICE _ #S1 - 6 RAINIER AVE S, STA 13+14 51.5' LT "DECORATIVE" 135W LED (M-II-FC) 240V 1 6' 35' 40' B 7706NL SERVICE #S1 7 RAINIER AVE S, STA 14+00 53.5' RT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40' B 7705NL SERVICE #S1 - _ -- 8 RAINIER AVE S, STA 14+41 53.0' LT "DECORATIVE" 135W LED (M-II-FC) 240V 12' 35' 40' C 7708N SERVICE #S1 - 9 RAINIER AVE S, STA 15+29 53.5' RT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40' C 7707NL SERVICE #S1 P4 SHARED POLE "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 40' D 7704NL SERVICE #S1 _ P5 RAINIER AVE S, STA 12+23 53.5' RT "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 18' D 7710L SERVICE #S1 P6 RAINIER AVE S, STA 12+66 51.5' LT "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 18' D 7709L SERVICE #S1 P7 SHARED POLE "DECORATIVE" 60W LED (S-III-FC) 240V 4 14' 40' D 7703NL SERVICE #S1 P8 SHARED POLE "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 40' D 7706NL SERVICE #S1 P9 RAINIER AVE S, STA 13+41 53.5' RT "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 18' D 7711 L SERVICE #S1 P10 SHARED POLE "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 40' D 7705NL SERVICE #S1 P11 RAINIER AVE S, STA 14+65 53.5' RT "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14 18' D 7713L SERVICE #S1 P12 P13 RAINIER AVE S, SHARED STA POLE 15+35 42.0' LT "DECORATIVE" "DECORATIVE" 60W 60W LED LED (S-III-FC) S-III-FC 240V 240V 4' 4' 14' 14' 18' 40' 1 D D 7712L 7707NL SERVICE SERVICE #S1 #S1 f? FEHR &L PEERS TRANSPORTATION CONSULTANTS 1001 4th Avenue. ° Wairct creek. CA ° Orange Canty. CA ° Ros Hle. CA ° Los Angeles Canty. CA Suite 4120 ° Say J_ CA ° Say Dlego, CA Seattle. WA 98154 ° S " FfHfO SM CA ° salt sake City. UT (206) 576-4220 NV ° S. ttie. tAa CA ° aan. . ° Seettle. wA ° Denier. 00 KPG 753 9th Ave N 2502 Jefferson Ave Seattle, WA 98109 Tacoma, WA 98402 (206) 286-1640 (253) 627-0720 www.kpg.com }'- CITY OF RENTON .J1 Public Works Depertmen. APPROYyb FOR CONSTRUCTION BY: DATE:10 r. 3430169 0 5 10 20 40 :' SCALE IN FEET RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST ILLUMINATION AND INTERCONNECT PLAN STA 12+00 TO STA 15+50 BID OC MEN I L>RAWING NO. PROJECT NO. TED403430 FED AID NO. CM0167(048) DATE: NOV 2011 SHEET NO. 229 OF 304