Loading...
HomeMy WebLinkAboutTRO4103430.98LEGEND EXISTING NEW DESCRIPTION SIGNAL POLE WITH MAST ARM XXXX DENOTES EX TYPE I OR PS POLE POLL DECALf Xxxx EXISTING LUMINAIRE 4 3123H DECORATIVE PEDESTRIAN LUMINAIRE C--Gl DECORATIVE ROADWAY LUMINAIRE cn DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE SIGNAL CONTROLLER CABINET t ELECTRICAL SERVICE CABINET A.. ITS CABINET m L El JUNCTION BOX TYPE 1, 2, 8 164 co 25-TA VAULT k., CIO CONDUIT WIRE NOTE / CONSTRUCTION NOTE op, '1� Ile r LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S5" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) LUMINAIRE # STATION OFFSET LUMINAIRE TYPE LUMINAIRE MOUNTING POLE 1 CIRCUITDECAL C" 0 M M EEN T S ARM HEIGHT TYPE # # I El 135W LED (M-III-FC) 240V W/PHOTOCELL A 7791N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN E2 -"DECORATIVE" 135W LED (M-III-FC) 240V A 7793N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN E3 "DECORATIVE" 135W LED (M-III-FC) 240V A 7792N * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN 52 RAINIER AVE S, STA 45+13 53.5' LT "DECORATIVE 135W LED (M-11 FC) 240V 6 35' 40' C 7794NL SERVICE #S5 53 RAINIER AVE S, STA 45+16 561 RT "DECORATIVE" 135W LED (M-11-FC) 240V 12' 35' 4. B 7795N SERVICE #S5 54 S SUNSET BLVD, STA 551+24 43.1' LT "DECORATIVE" 135W LED (M-II-F-C-) 240V 6' 35' 40' C 7796N SERVICE #S5 55 S SUNSET BLVD, STA 551+26 50.2' RT "DECORATIVE" 135W LED (M-II-FC) 240V 6' 35' 40' 8 7797N SERVICE #S5 56 RAINIER AVE S, STA 47+23 6 5.4' LT "DECORATIVE" 135W LED (M-III-FC) 240V 6' 35' 40' j C 7798N SERVICE #S5 57 RAINIER AVE S, STA 47+89 52.2' LT "DECORATIVE" 135W LED (M-II-FC) 240V 61 35' 401 B 780ONL SERVICE #S5 P70 SHARED POLE "DECORATIVE" 60W LED (S-III-FC) 240V 4' 14' 40' D 7794NL SERVICE #S5 48 4ql L'Al RACEWAY/ # CONDUIT CONDUCTORS COMMENTS SIZE 2" 2#8 SEE NOTES BELOW 2 J 408 NOTES BELOW 3 1 2" 6#8 ---SEE- SEE NOTES BELOW 4 4"-- SPARE 4 1-96 SMFO SEE NOTES BELOW 6 2" SEE NOTES BELOW EX. SEE NOTES BELOW 8 4" EX. 1-48 SMFO RE—ROUTE NOTES: 1 ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1-#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL -LINE TAPE AND LABELED "CITY OF RENTON". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. CONSTRUCTION NOTES CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT/WRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT- GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. CONSTRUCT FOUNDATION PER DETAILS ON (ZWPPT 963 AND FURNISH AND INSTALL ELECTRICAL qP*PkArI7 rAPIKIPT PER COP STD DWGS J010 AND J011 WITH BACK—TO—BACK BATTERY BACKUP SYSTEM PER SPECIAL PROVISIONS. FOR LOCATION AND PANEL S T SCHEDULE, SEE ILLUMINATION CIRCUIT DIAGRAM AND DETAILS SHEET 238. COORDINATE CONNECTION DETAIL 10 THE POWER SOURCE WITH THE POWER COMPANY REPRESENTATIVE PRIOR TO INSTALLATION OF FOUNDATION. SEE SPECIAL PROVISIONS. --SEE SIGNAL PLAN EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. FOR DETAILS 5 CATION DETAILS SEE SERVICE 20 ING TO POLE, FOR ADDII ONAL lNSTALLA \ GENERAL NOTES Q LUMINAIRE TO BE PART OF A SIGNAL SYSTEM. APPLY DECAL NUMBER, I 409H SIGNAL PLANS. 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE 10 CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. RAW 2. UTILITY LOCATION (DIAL —A —DIG) PRIOR TO CONSTRUCTION SHALL BE THE GENERAL NOTES (CONTINUED) RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT EXISTING SIGNAL POLE MOUNTED LUMINAIRE. FOR REMOVAL NOTES SEE SIGNAL PLANS, TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT, 4 ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. FOR EXISTING JUNCTION BOX REMOVAL/MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN 40 456-2701 PRIOR TO INSTALLATION OF METER BASE. -Qr- 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR ACCORDANCE WITH SECTION 8-20.3(1)A OF THE SPECIFICATIONS, THE 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WRING. COG 05 SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED 'ITS". co 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE T 3430177 RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER CONSTRUCTION, COORDINATE WORK WITH THE POWER COMPANY 20 SEE URBAN DESIGN PLAN SHEETS FOR CONTINUATION OF ARCHITECTURAL LIGHTING. COR STD PLAN #127. REPRESENTATIVE. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY, FINAL 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' F31D LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT, SPLICE EXISTING WRING IF NECESSARY TO MAINTAIN BY THE ENGINEER IN THE FIELD. CONNECTIONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. DOCUMENTS 1 ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12-16-1 1 SURVEYED: KPG c. RAINIER AVENUES (SR 167) DRAWING NO. 237 DRAWN BY: im CfTY OF RENTON I.SN _V/ ]PCX mll �_'T NO. TED40341'30 S GRADY WAY TO S 2ND ST PRCjJEI- DESIGN BY: JF FEHP, PEEPS 753 9th Ave N , 2502 Jeffmon Ave J F TRANSPORTATION CONSULTANTS Seaftle, WA 98109 Tawma, VVA 98402 ILLUMINATION AND INTERCONNECT PLAN FEDAIDNO, CM0167(048) CHECK BY. APPROV DATE: NOV 2011 4 F, 4 rn° (206) 286-1640 (253) 627-0720 FOR CONSTIRLICTION PROJ MGR: TN 0 AL www.kpg.com BY: DATE STA 45+00 TO STA 49+00 SHEET NO. 237 OF 304 �NUMBER REVISION DESCRIPTION BY APP. DATE I FILE: 0655DILLOl.dwg T I I- to O CD 0