Loading...
HomeMy WebLinkAboutWTR2703430.24N c� N CD N a C7, 0 ry n Q a Ln Ln QCD i U z: cry v w 0 n, n s 04, WEST GUTTER LINE EAST GUTTER LINE wAS 11-14-11 SURVEYED: KPG DRAWN BY: SOD 1pclk �� CITY OF RENTON OS��R B I p r!1 DESIGN BY: SOD 753 9th Avenue N 2502 Jefferson Avenue Public Works Department �� CHECK BY: NJD Seattle, WA 98109 Tacoma, WA 98402 DOCUMENTS APP FOR CONSTRUCTION 20320.� w� � G�sTe� ��I�NAL V, PROJ MGR: JF 206 286-1640 (253 627.0720 � � www,kpg.com 4ED BY: /r DATE: 1f NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DWATPRF01.dwg GENERAL WATER CONSTRUCTION NOTES EXISTING WATER MAINS, HYDRANTS, AND SERVICES SHALL REMAIN OPERATIONAL THROUGHOUT THE COURSE OF CONSTRUCTION EXCEPT WHERE WATER BYPASS SYSTEMS ARE REQUIRED. FOR INSTALLATION OF WATER BYPASS SYSTEMS SEE TEMPORARY WATER BYPASS PLANS, SHTS 160-163. ABANDONMENT AND/OR REMOVAL OF EXISTING MAINS SHALL TAKE PLACE ONLY AFTER THE NEW MAIN OR WATER BYPASS SYSTEM HAS BEEN INSTALLED, TESTED, AND APPROVED BY THE CITY OF RENTON. 2. MAIN SHUTDOWNS SHALL BE BY CITY MAINTENANCE STAFF ONLY. CUT -IN CONNECTIONS TO EXISTING MAINS SHALL ALSO BE PERFORMED BY CITY STAFF, CONTRACTOR SHALL PROVIDE TWO WEEK ADVANCED NOTICE TO CITY FOR SCHEDULE OF CONNECTIONS AND SHUTDOWNS. 3. EXISTING SERVICE LINES, METER SETTERS, AND METER BOXES ARE TO BE REPLACED AS PART OF THIS PROJECT. EXISTING METERS ARE TO BE RESET WITHIN THE NEW SETTERS. COORDINATE W/CITY OF RENTON. 4. DEFLECT JOINTS AS NECESSARY TO INSTALL WATER MAIN WITH MINIMUM COVER ALONG THE APPROXIMATE LOCATION SHOWN. PIPE JOINTS NOT TO EXCEED 50 PERCENT OF THE MAXIMUM JOINT DEFLECTION SPECIFIED BY THE PIPE MANUFACTURER. 5. ABANDONED EXISTING WATER MAINS SHALL BE CAPPED WI sH (MJ) CAPS. PORTIONS OF THE ABANDONED WATER MAIN MAY REQUIRE REMOVAL FOR THE CONSTRUCTION OF OTHER ROADWAY IMPROVEMENTS. 6. EXISTING FIRE HYDRANTS SHALL BE REMOVED AND PROPERLY DISPOSED OF BY THE CONTRACTOR AFTER INSTALLATION, TESTING, AND APPROVAL OF THE NEW HYDRANTS. 7. VERIFY LOCATION AND DEPTH OF EXISTING WATER MAINS z T AL_ C=ONNE-CTION PO!NTS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL FIELD VERIFY TI1E OUTSIDE DIAMETER (O.D.) OF ALL EXISTING CAST-IRON AND ASBESTOS -CEMENT PIPES, AND PROVIDE THE PROPER LONG -BODY ADAPTERS AND TRANSITION COUPLINGS FOR THE FINAL CONNECTIONS BY CITY FORCES. CONNECTIONS TO ALL DUCTILE IRON PIPES SHALL BE MADE WITH LONG SOLID SLEEVE COUPLINGS (MJ). 8. ALL CONNECTIONS TO EXISTING WATER LINES SHALL BE MADE ONLY AFTER ALL THE NEW WATER LINES AND APPURTENANCES HAVE SUCCESSFULLY PASSED ALL PRESSURE TESTS, CLEANED WITH POLY -PIGS, DISINFECTED WITH CHLORINE SOLUTION, AND HAVE RECEIVED SATISFACTORY BACTERIOLOGICAL TEST LAB REPORTS, AND ARE THOROUGHLY FLUSHED. 9. ELEVATIONS OF EXISTING CROSSING UTILITIES ARE PARTIALLY BASED ON RECORD DRAWING INFORMATION. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL.. UNDERGROUND EQUIPMENT PRIOR TO CONSTRUCTION AND INFORM THE ENGINEER IF CONFLICT IS FOUND. 10. ALL WATER MAINS, FITTINGS, AND APPURTENANCES SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAILS INCLUDED WITH PROJECT SPECIFICATIONS. 11. WATER PIPE AND FITTINGS INDICATED ON PLANS SHALL HAVE RESTRAINED JOINTS PER SPECIFICATIONS. SEE WATER PLANS, SHTS 132-141 AND WATER PROFILES, SHTS 146-159 FOR THESE LOCATIONS. 12. PROVIDE 10' HORIZONTAL SEPARATION FROM PARALLEL SEWER LINES. WATER SHALL CROSS OVER EXISTING SEWER WITH 18" MINIMUM VERTICAL SEPARATION. WATER SHALL CROSS ALL. OTHER UTILITIES WITH 12" MINIMUM VERTICAL SEPARATION. CONCRETE ENCASEMENT MAY BE NECESSARY WHERE THESE REQUIREMENTS CANNOT BE MET. 13. ALL WATER MAIN VERTICAL BENDS SHALL INCLUDE VERTICAL THRUST BLOCKING PER RENTON PLAN 330.3. ALL WATER MAIN HORIZONTAL BENDS SHALL INCLUDE HORIZONTAL THRUST BLOCKING PER RENTON PLAN 330.2. 0 5 10 20 40 60 HORIZONTAL SCALE IN FEET VERT. SCALE--1/2 HORIZ. SCALE W=343024 CORRESPONDING SHEETS CATEGORY SHEET RIGHT OF WAY PLANS 16 EXISTING CONDITIONS 64 SITE PREPARATION & TESC PLAN a 78 ALIGNMENT PLAN 90 ALIGNMENT PROFILE 102 DRAINAGE PLANS 113 DRAINAGE PROFILE 123,124 WATER PLAN I 141 WATER PROFILE — JOINT UTILITY TRENCH PLAN 173 JOINT UTILITY TRENCH PROFILES 189 PROPERTY RESTORATION PLANS 204 CHANNELIZATON & SIGNING PLAN 226 --T ILLUMINATION PLANS 237 IRRIGATION PLAN 291 LANDSCAPE PLAN 303 RAINIER AVENUE S (SR 157 S GRADY WAY TO S 2ND ST WATER PROFILE STA 45+00 TO STA 49+00 5 PROJECT NO. TED403430 FED AID NO.-CM0167(048) DATE: NOV 2011 SHEET NO. 155 OF 304