Loading...
HomeMy WebLinkAboutWTR2703430.70 Q Ln t� 0 / �r 0 0 U / 0� 0 / z CD V) w 0 / 0 Q Q) Of i 0 0 / z z w cn U L.L1 O .. I I I' I I i I OD I � I I I I i 1 I I � I I I 1 _j a.I C i I I I I I - EXISTI i I 12" D i -P_ I I I I i I SEE CONNECTION 12IDET L, IT 144 _ WATER LAYOUT TABLE STA OFFSET LT OFFSET RT SIZE 34+00 34.5' -- 12" 34+50 34.5' 34.5' 12" 35+00 34.5' 34.5' 12" 35+50 _ 34.5' -- 12" 36+00 34.5' -- 12" 36+50 34.5' -- 12" 37+00 34.5' -- 12" 37+50 ! 34.5' -- 12" 38+00 34.5' -- 12" WATER LEGEND ABANDON OR REMOVE EXISTING WATER MAIN j PROVIDE RESTRAINED JOINTS PER SPECIFICATIONS WATER CONSTRUCTION NOTES O FURNISH AND INSTALL CLASS 52 DUCTILE IRON WATER PIPE. SEE WATER LAYOUT TABLE FOR STATION, OFFSET AND SIZE THIS SHEET. FURNISH AND INSTALL LONG SOLID SLEEVE COUPLING AND PROVIDE CONNECTION TO EXISTING WATER MAIN. SEE TYPICAL_ CONNECTION TO EXISTING MAIN DETAIL, SHT 142. APPROXIMATE STA 34+23.8, 55.4' LT 1 - 12" COUPLING, MJxMJ FURNISH AND INSTALL TEE. STA 34+07.1, 34.5' LT 1 - 12"x12"x12" TEE, FLxFLxFL 3 - 12" GATE VALVE, MJxFL 1 - THRUST BLOCK STA 34+07.1, 34.5' RT 1 - 12"x12"x12" TEE, FLxFLxFL 3 - 12" GATE VALVE, FLxMJ 1 - THRUST BLOCK APPROXIMATE STA 351+17.5, 10.91' RT 1 - 8" COUPLING, MJxMJ STA 34+23.0, 34.5' LT 1 - 12"x12"x12" TEE, MJxFLxFL 2 - 12" GATE VALVE, MJxFL 1 - THRUST BLOCK STA 35+13.6, 34.5' RT 1 - 12"x12"x12" TEE, MJxMJxFL 1 - 12" GATE VALVE, FLxMJ 1 - 12" CAP, MJ 1 - THRUST BLOCK GENERAL GENERAL WATER CONSTRUCTION NOTES 1. SEE GENERAL WATER CONSTRUCTION NOTES ON NEXT SHEET. 07 FURNISH AND INSTALL 45 DEG BEND. STA 33+95.0, 66.4- RT 1 - 12" 45' BEND, MJxMJ 1 - I-HRUST BLOCK 9� FURNISH AND INSTALL GATE VALVE. STA 37+80.0, 34.5' LT 1 - 12" GATE VALVE, MJxMJ STA 34+06.4, 56.5' RT 1 - i 2" 45' BEND, MJxMJ 1 - THRUST BLOCK 10 FURNISH AND INSTALL FIRE HYDRANT ASSEMBLY PER CITY Or RENTON STANDARD FLAN 310.1. STA 34+92.5, 46.3' LT STA 37+91.7, 46.3' LT STA 35+21.4, 46.3' RT 15 FURNISH AND INSTALL WATER SERVICE METER PER RENTON STD PLANS 320.1 - 320.3 AND CONNECT TO EXISTING SERVICE LINE. APPROXIMATE STA 351+03.8, 31.3' RT 1 - 1 1 /2" METER 1 - METER BOX APPROXIMATE STA 35+87.9, 46.5' LT 1 - 1" METER 1 - METER BOX APPROXIMATE STA 37+82.6, 46.5' LT 1 - 3/4" METER 1 - METER BOX APPROXIMATE STA 34+60.8, 60.6' LT 1 - 3/4" METER 1 - METER BOX APPROXIMATE STA 37+77.5, 46.5' LT 1 - 3/4" METER 1 - METER BOX APPROXIMATE STA 37+87.2, 46.5' LT 1 - 1" METER 1 - METER BOX 23 ADJUST UTILITY MANHOLE (COVER) TO GRADE. 26 FURNISH AND INSTALL 12" CLASS 52 DUCTILE IRON PIPE. 31 FURNISH AND INSTALL BLOW -OFF PERMANENT ASSEMBLY PER RENTON STD PLAN 340.1. STA 35+13.6 59.5 RT 1 _ 12BLOW OFF VALVE., M =xMJ t I� 1 - 12f9 CAP, MJ F-- - 1---------�44- Lf-PIPE-- ---- - 1--------------------------------------------- 3 9 - 1 - THRUST BLOCK I ICI / I 26 C w Lij �-- 26 I = 34 FURNISH AND INSTALL 12"x8" REDUCER AND 8" CLASS 52 DUCTILE IRON WATER PIPE AS C I I I I I LF� PIPE cn CD NECESSARY NECESSARY (LENGTH OF PIPE MAY VARY DEPENDING ON PLACEMENT OF COUPLING) TO CDI l I I15 INSTALL COUPLING AND CONNECT TO EXISTING SYSTEM. LO I i I 1 I I i I I I 35 36 -{- °'� 37 FURNISH AND INSTALL IRRIGATION METER PER RENTON STD PLAN 320.2 AND CONNECT o TO EXISTING SERVICE LINE. I I I I I _ CIOI c~n I I ► I I z APPROXIMATE STA 35+81.9, 46.5, LT ,� z I 1 I I, 26 I I I I 1- 1 1/2" METER -' ---_j L� I I L 1 -METER BOX I 3 RAINIER AVE S Q of I 3 1 L_-.J-186--L �P-€------------ _ --------.------ --- --- --------- CORRESPONDING SHEETS I L� ,� , �\ 1 I I 1 I I I 1 0 5 10 20 40 60 SCALE IN FEET WM343007 CATEGORY SHEET RIGHT OF WAY PLANS 13 EXISTING CONDITIONS 61 SITE PREPARATION & TESC PLAN 75 ALIGNMENT PLAN 87 ALIGNMENT PROFILE 99 DRAINAGE PLANS 110 DRAINAGE PROFILE WATER PLAN 120,121 -� WATER PROFILE 152,158 JOINT UTILITY TRENCH PLAN 170 JOINT UTILITY TRENCH PROFILES 186 PROPERTY RESTORATION PLANS 201 CHANNELIZATION & SIGNING PLAN 223 234 ILLUMINATION PLANS IRRIGATION PLAN 288 LANDSCAPE PLAN 300 11-1a-11 Q�G>ACo F wAsyj�y �� �N _ o - �Fc�TERti� cSk� �� SURVEYED: KPG DRAWN BY: SOD/KH DESIGN BY: SOD/KH CHECK BY: JLF_ PROJ MGR: JF FILE: 0655DWAT01.dwg KPH 753 9th Avenue N 2502 Jefferson Avenue BID Seattle, WA 98109 Tacoma, WA 98402 D O C U I V 1 E N TS (206)286.1640 (253I627-0720 www,kpg,com •• �-CITY OF RENTON Public Works Department APPROVED FOR CONSTRUCTION '` � BY: �`' DATE: /Z RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST WATER PLAN STA 33+50 TO STA 38+00 DRAWING NO. 138 __. PROJECT NO. TED403430 FED AID NO.-CM0167(048) DATE: NOV 2011 SHEET NO.38 OF 304_ NUMBER REVISION DESCRIPTION BY APP. 777��`�loNaL DATE