MORTAR
FILLET
BECLAN PLACE -MINOR AMENDMENT
A PORTION OF THE NW 3/4 OF THE
NE 1/4
OF SEC.
15, TWP. 23N., RGE. 5E., W.M.
CITY
OF
RENTON,
KING
COUNTY,
WASHINGTON
MANHOLE FRAME AND COVER
SEE DRAWING BR29
ADJUSTMENT (4" MIN.)
CONE
RUBBER GASKETED JOINTS
IN ACCORDANCE WITH ASTM C-443
STEPS - 3/4" DEFORMED BAR
STEPS SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
MAX. PIPE SIZE - 'E'
LADDER -STD. ALUMINUM
OR GALVANIZED STEEL
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
SANITARY MANHOLE TYPICAL DETAIL
NOT TO SCALE
Z
3
= 18
zZ
=
_
' 8
o
0
V)
<Z
<J
N
SANITARY SEWER NOTES AND SPECIFICATIONS
�,
a
�,
oW15
Z a�
1
~
2
��
Y
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE
o
I
o
0
11
CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND
SPECIFICATIONS.
D_
a
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 A.M. TO 3:30 P.M. ON
Q
WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT
AT 235-2620. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE
w
PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT 72 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE
o
DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY.
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS FOR MUNICIPAL PUBLIC
m
WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION,
LATEST EDITION (APWA) AND CITY OF RENTON STANDARD SPECIFICATIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE.
5. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW
CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO
STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF
RENTON,) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN
ADVANCE OF BACKFILLING ALL CONSTRUCTION.
z
0
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND
FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE.
If
w
O
Z
NOTES:
1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY
STEPS OR EQUAL.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS
ARE INSTALLED.
3. CASTING TO BE PER DRAWING BR29.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST
CONCRETE.
5. ALL JOINTS SHALL BE GROUTED.
6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
WITH A HIGH SOLIDS URETHANE COATING;
WASSER MC-CONSEAL OR APPROVED EQUAL;
COLOR OF COATING SHALL BE WHITE.
7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
WITH ASTM C-443.
8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE
DIAMETER OF THE LARGEST PIPE.
9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK
ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL.
'A'
'B'
'C
'D'
'E'
48" MH
48"
6" MIN.
5"MIN
24" MIN.
21 " I.D.
54" MH
54"
8" MIN.
5.5" MIN.
24" MIN.
24" I.D.
60" MH
60"
8" MIN.
6" MIN.
42" MIN.
30" I.D.
SANITARY MANHOLE TYPICAL DETAIL
Y O ADOPTED
U CITY OF RENTON
♦ l i�
STANDARD PLANS
N `O� LST DATE: 12/96
DWG. NAME: BR28 SP PAGE: B071
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED
PERMITS PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT, SHALL TAKE PRECEDENCE OVER
ALL OTHER PLANS.
9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN
PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY
SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED
PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE
DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF
MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS
DESCRIBED.
12. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE
BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED, CUTS INTO THE EXISTING ASPHALT SHALL BE
NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY
AFTER BACKFILL AND COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND
SHALL BE PER CITY OF RENTON CURRENT STANDARDS.
13. DATUM SHALL BE CITY OF RENTON, U.S.C. AND G.S.
14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION
OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION.
6" MIN.
I
1 /2 BLIND FLANGE AS DAM
D.I.P. TEE CL.50-
ONE LENGTH OF DUCTILE IRON
PIPE (CLASS 50) TO SOLID
BEARING WHEN SPAN
IS MORE THAN 4'.
L FLEXIBLE
JOINT
BACKFILL WITH
COMPACTED MATERIAL
AS DIRECTED BY
ENGINEER.
D.I.P. C1.50 6" MIN.
WITH MIN. 4
SHACKLE RODS
CEMENT CONCRETE
CLASS C BLOCK
POURED IN PLACE
D.I.P. 90" BEND
CL.50(MJ X PE)
DUCTILE IRON
DROP CONNECTION
X
Q
CCv
X
Q
1 /2 PLUG AS DAM
TYPICAL TEE
MANHOLE
X
Q
0
cu
`'� TYPICAL MANHOLE
FOUNDATION
CONSTRUCTION
10 17
3/6/
9
12 15
DATE
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE
WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND
BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF
THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO
UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE
UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35,
OR DUCTILE IRON CLASS 50.
17. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 18 INCH ABOVE FINISHED
GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
VERTICAL DATUM:
CITY OF RENTON, NAVD 88
BENCHMARK
CITY OF RENTON BENCHMARK #2104. 1 " IP
W/PLUG & TACK DOWN 0.9' IN CASE LOCATED
AT THE INTERSECTION OF SE 136TH ST. AND
144TH AVENUE SE. ELEV.=399.340 FEET (121.719
METERS)
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date
Date
Date
CONCRETE ENCASED
DROP CONNECTION
Edited text
NO. I REVISION
REVISION
r-6" MIN.
6" MIN.
ONE LENGTH OF DUCTILE IRON
PIPE (CLASS 50) TO SOLID
BEARING WHEN SPAN
IS MORE THAN 4'.
FLEXIBLE JOINT
BACKFILL WITH
COMPACTED MATERIAL
AS DIRECTED BY
ENGINEER.
CEMENT CONCRETE CLASS C POURED IN PLACE
90° BEND
(TYTON U-651)
DROP CONNECTION FOR SANITARY SEWERS
ADOPTED
CITY OF RENTON
STANDARD PLANS
LST DATE:12/96
PPR'D DWG. NAME: BW18
S 3446 15
CALL 48 HOURS
BEFORE YOU DIG
1-800-424-5555
BY I APPR. I DATE
a3•o[ • l3
SP PAGE: B075
AWSCHWEIKL &
kIdAsmiAms, Puc
CIR 81 A PNMT rA1M T
1945 S. 375TH STREET Bw (253) 226-AM
FEDERAL WAY, WA 98003 bSChvv&fSAciv#.ne(
CITY OF- RENTON
DEPARTMENT OF PUBLIC WORKS
BECLAN (AKA BECLAN PLACE)
SANITARY SEWER NOTES AND DETAILS