Loading...
HomeMy WebLinkAboutWWP2703446.13re)cV U u7 N o- \ 00 N co o `— Z U �y I J Q U g o z CD Z Q o 0 zwz Q W 0 mWoo Q Q Jz y <0M ry LLJ W w W r-Y a M Q W Q a z Q Cn U n Q d t� O U '-' w Uri o a 104 m I s` o I � Z 3 J v" ZZ 0 V Z W Ct io N W �a 5� vi O Z < ,� Q in oWLL Q) � (!q� Bm H om c z W asa IZ IZ Q W Q d Ld x m 1-1/4'j 10" 9„ 8-3/4" 1 /2' 2" i� " SQUARES SPACED 3/4" INDICATED — HT. 1 /8" 1 /2„ RAISE-1 /2" WIDE BORDER 5/8„ 7T/8" 4" BECLAN IAKA BECLAN PLACE) • MINOR AMENDMENT A PORTION OF THE NW ?4 OF THE NE i4 OF SEC. 15, TWP, 23N., RGE, 5E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON 12"9 FIBER PAC K I I 45° (1 /8) PIPE MATERIAL AS SPECIFIED BY THE ENGINEER CONCRETE CLASS 3000 3/4„ - 7„ , '.r'' CO e• 7-3/4„ 8" 15" PLUG TO BE SEALED CAST IRON RING AND COVER IN SAME MANNER AS MAIN SEWER JOINTS. NOTE: IN UNIMPROVED AREAS POUR 1'-0" THICK 6 INCH OR 8 INCH CLEAN —OUT 2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND RING AND COVER. ��� Y O� ADOPTED IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUT RING CITY OF RENTON AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36. STANDARD PLANS LST DATE: 12/96 10/17/96 Added notes. DCv AG DWG. NAME: BW18B SP PAGE: B076 DATE REVISION IBY APPR'D ALL 90' TURNS SHALL 4" CLEANOUT WYE WITH BE ACCOMPLISHED BY MEANS NOTES: 45' BEND AND PLUG. OF A WYE AND 45' BEND, Z Li Z Z TWO 45' BENDS SHALL NOT 1. Prior to installation of a sanitary sewer connection, J J Renton Public Works Department. BE ACCEPTABLE. a side —sewer permit must be purchased from the City of 2. Types of pipe and fittings that can be used for sanitary w Ljj w sewers shall be approved by the Department of Public Works. a- G_ a_ Rubber or neoprene gaskets as specified by the manufacturer, o � � shall be used on joints. HOUSE HOUSE w HOUSE CL HOUSE 3. A minimum grade of 2% (1/4" per foot) must be maintained with 4" pipe. In the event a 2% grade cannot be maintained. The owner must grant a —0" MIN. ggrade release to the City and then can install 6" pipe at a grade of 1%. 733- . 4. For inspection of side sewer, call 24 hours 4" SEWER PIPE in advance, 277-5570. Site must be ready for inspection �BEND AS REQUIRIED (TYPICAL) and representative on site when inspector NO MORE THAN 45' BEND). 4" SURFACE arrives at appointed time. Side sewer and stub VERY 2ND CHANGE IN 4" SEWER PIPE, SEE NOTES 2 AND 3. shall be tested per City specifications. DIRECTION OR GRADE WILL CWLYEEANOUT 4" TEST TEE WITH MINIMUM LINE SIZE FOR OTHER THAN Make the connection at the house. Do not backfill REQUIRE A SURFACE PLUG FACE UP SINGLE FAMILY 1 S 6" the ditch until approval is given by the inspector. V CLEANOUT WYE, 4" CLEANOUT (TYPICAL) Final approval will be granted after the existing 1 WYE WITH PLUGr, septic tank has been pumped out and filled with sand. PROPERTY LINE PROPERTY LINE 5. Install side sewer with 2' minimum cover. 18" � 6' MIN. � `D `D cover is allowed at the house Tf outlet is shallow. z z CD 6"x 4" REDUCER CD Z (TYPICAL) Z 6. If side sewer stub is not available. The owner shall C'nV) V V) be responsible for its installation. The side sewer w ! MAIN SEWER LINE LX w Ix shall be a minimum of 6" in size. If tee is not available, the main sewer line must be tapped thru a cast iron saddle. All work within TYPICAL BUILDING SEWER INSTALLATION PLAN street right—of—way shall be done by a licensed and bonded contractor. z 4" SOIL PIPE 7. All work shall be accomplished in accordance of z IF THE BUILDING SEWER SERVES ANY FIXTURE with the Washington Industrial Safety and 0 4" CALDER COUPLING X Q Health Act. (WISHA) -, HAVING FLOOD LEVEL RIMS LOCATED BELOW THE o N OR EQUAL TO FIT Q 8, All trench restoration for side sewers in the public I ca o � � ELEVATION OF THE NEXT UPSTREAM MANHOLE COVER SURFACE CLEANOUT - oZ OF THE PUBLIC SEWER SYSTEM, A BACKFLOW PREVENTION right—of—way shall conform to the most current trench 4"x 4"x4" WYE f o DEVICE SHALL BE INSTALLED EQUAL TO TYPER 2-84. restoration requirements as shown on dwg. #HR-23. J m L 9. All building sewer and side sewers shall have m bedding in accordance with drawing BW18C or 4" PIPING BR09 as applicable. 4"x 4"x 4" TEST TEE CD 4" CALDER COUPLING o w Z OR EQUAL TO FIT 10. There shall be a minimum 10 foot horizontal seperation I FACE UP AND PLUGGED o between sanitaryside sewers and water services and a Ln ® 3 4" NIPPLE J w SURFACE CLEANOUT minimum 5 foot horizontal seperation between sanitary side _z = cn 6"x 4" REDUCER m 4"x 4"x4" WYE sewers and _d other utilities. J z o 6" COUPLING TO FIT 4" PIPING ~ z END 6" PIPE w o z REMOVE 2 PLAN "x4" STUD AND CAP OR PLUG — TYPICAL BUILDING SEWER — o U_ m ON END OR EXISTING 6" SEWER PIPE. BUILDING DRAIN ate. of AND INSTALL BUILDING SEWER COUPLINGS, FOR LOW HOUSE SIDE SEWER (PROPERTY LINE) � REDUCER, TEES, AND BENDS AS REQUIRED. TO BUILDING CONNECTION PROPERTY i LINE w INSTALLATION PLAN of SEE SIDE SEWER DETAIL o z � 6" PIPING TO 6'-0" ��� Y a ADOPTED w BEYOND PROPERTY LINE n CITY OF RENTON z � Li Ld6" SIDE OUTLET TEE CALL FOR LOCATIONS BEFORE YOU DIG :2[L o SEE NOTE 6 SEWER MAIN MR p , 65 48HR LOCATORS 1-800-424-5555 � STANDARD PLANS PLAN F N (O LST DATE: 12/96 BUILDING SEWER INSTALLATION 10/17/9Edited text DCv AG DWG. NAME: BR35 SP PAGE: 8082 DATE REVISION BY PPPR'D Ir 1 /2" WEB 8 PL. FRAME (NON -LOCKING) A to TYP. '2" x 3" x 3/8" NON—SKID PATTERN ST INTEGRAL ON TOP COVER (NON -LOCKING) FOR 5/8"-11 N.C. x 1-1/4" B S.S. SOC. HD. CAP SCREW (3 REQ'D.) / -,--TYP. NON—SKID PATTERN 1 ' ' SEAT 2" RAISED LETTERS AS REQ'D. SEE NOTE No.3 BELOW UNDERSIDE SHOWN FOR CLARITY 3/4" CORE (TYP.) ON 23" B.C. DRILL AND TAP 5/8"-11 N.C. 1-1/2" CORE (TYP.) (LOCKING) ON 23" B.C.(TYP. 3 PL.) FRAME (LOCKING) COVER (LOCKING) NOTES: 1. FOR NON —LOCKING USE OLYMPIC FOUNDRY No. MH 30 OR EQUAL. 2. FOR LOCKING LID USE OLYMPIC FOUNDRY No. MH 30 D/T OR EQUAL. 3. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY ''WATER"). VERTICAL DATUM: CITY OF RENTON, NAVD 88 BENCHMARK CITY OF RENTON BENCHMARK #2104. 1" IP W/PLUG & TACK DOWN 0.9' IN CASE LOCATED AT THE INTERSECTION OF SE 136TH ST, AND 144TH AVENUE SE. ELEV.=399.340 FEET (121.719 METERS) CHECKED FOR COMPLIANCE TO CITY STANDARDS Date Date Date IIIIIIIIIIII'T 26-3/8" 25-1 /4" 24" —� —1-1 /4'' 23-1/4" 33-1/4" SECTION A -A I-- /o" z /o" SECTION B-B 1'' 3/4" MANHOLE FRAME AND COVER Cj0� Y ADOPTED CITY OF RENTON STANDARD PLANS �F N T O� LST DATE: 12/96 DWG. NAME: BR29 SP PAGE: B074 S=3446 16 CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 NO, I REVISION a bll: -3 4 LIIII 111111" (10 BY I APPR.I DATE SCHWENI & A Assocl ns, Pac CM A PWACT MANAGEEMIT 1945 S. 375TH STREET Bus' (25J) 226-4508 FEDERAL WAY, WA 98003 bschweW66AariLnet CITY OF- RENTON DEPARTMENT OF PUBLIC WORKS BECLAN (AKA BECLAN PLACE) SANITARY SEWER NOTES AND DETAILS DESIGNED: BAS DATE: 03/01/13 FILE NAME: 12183-C21 DRAWN: TAS CHECKED: BAS SCALE: AS SHOWN FIELD BOOK; PAGE: APPROVED; SHEET: C-21 OF: 25 DIRECTOR OF PUBLIC WORKS i �zz r 1 y v1 Z ri a> a