Loading...
HomeMy WebLinkAboutTED4003447.3NW 1/4 OF SEC. 15, TWP. 23N, RGE. 5E, W.M., KING COUNTY, WA LL1 Q Z U W 3 O ry n al EX. GRADE A y� 5' EX. CONIC. --� ` EX. GRADE RETAINING WALL i � �p�' ----J 1 IL 4-1 NEW BLDG r-NEW CURB NEW CURB E NEWA.C. W/ GUTTER \PLANTER PAVING SLOPE CONTRACTOR SHALL VERIFY --j DEPTH OF EX, CONCRETE WALL DUE TO NEW EXCAVATION. 12" MIN. REQ'D ABOVE BOTTOM OF FOOTING. (2)1 SECTION - WEST PROPERTY LINE GRADES SCALE: N.T.S. GRAPHIC SCALE 20 0 10 20 40 BO b. g � � oR 1z- $3 BAR JACH CORNER 18* MIN 10OP _ ONE 93 BAR HOOP FOR S' TWO Ri BAR HOOPS FOR 12' RECTANGULAR ADJUSTMENT SECTION PRECAST BASE SECTION NOTES 1, AS AN ACCEPTABLE ALTERNATE TO REBAR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. WIRE MESH SHALL NOT BE PLACED IN KNOCKOUTS. 2, THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 2(r KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 7 MINIMUM TO 15" MAXIMUM. PROVIDE A 1 S MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE- AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT SKA1.L BE IT 4, FRAME AND GRATE MAY BE INSTALLED WITH FLANGE DOWN OR CAST INTO ADJUSTMENT SECTION - 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR AND THE WALLS MAY BE SLOPED AT A RATE OF 124 OR STEEPER. 8. OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. F--- --- PIPE ALLOWANCES MAXIMUM PIPE MVITERIAL Wsm DIAMETER REINIFORCED OR tY PLAIN CONCRETE ALL METAL PIPE 16' CPSSP * 1S (STD. SPEC. 94z-,q SOLID WALL PVC 15' (STD. SPEC. s-05.12(1)) PROFILE WALL PVC (STD. SPEC. B-05.T2(2)) � a rWr �✓JONAL V I.E1tP'i1F5 ARY l 20& * CORRUGATED POLYETHYLENE CATCH BASIN TYPE 1 STORM SEWER PIPE STANDARD VLM LI 9EET I OF t L@T FOR ft�AWrAWMN J lf�vld J�PNEnr/Ys0 07-Si-09 _ __._ ADOPTED OF RENTON CITY 9' STANDARD PLANS Q LAST DATE: 0712112003 SP PAGE B012 LEGEND EXISTING --8„- - --12 DD-- Rdwr34y7o.3 - -a- iJAL W..,L W-4 .il v .L tl ►.11 Z 4 A t G �I L��'-j6 S y,� 91 � Ot A D rnV J n = 201 HORIZONTAL NAD 1983/1991 :� _ CITY OF f G• Y DESIGNED: �� 1 �- PF DESIGN GROUP, INC. 2 CKE COMMENTS PAD 4 14 08 PAD RENTON 1 REVISE PER CITY COMMENTS PAD 3 24 08 PAD DRPW"` CIVIL ENGINEERING &LANDSCAPE ARCHITECTURE '��g,�tF9 PAD I ONE INCH DATUM PERMIT SUBMITTAL PAD 2 8 08 PAD CHECKED: AT 5212 37th Avenue SW Seattle WA 98126�OfVAL 4/14/08 TDG JOB# PAD FULL SCALE IF NOT Planning/Building/Public Works Dept. ONE INCH phone 206.923.0590 fax 206.923.3507 email off ice®terraformadesigngroup.com EIS 6�1r100B 07029 N0. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY rJ:496M CONCRETE CONC. BLOCK WALL PROPERTY LINE R.O.W. CENTERLINE EASEMENT '100 GRADING CONTOUR 9� SPOT ELEVATION - - — - SWALE - - - - - - GRADE BREAK WATER MAIN SEWER MAIN 12 D STORM DRAIN FIRE HYDRANT WATER METER GATE VALVE SEWER MANHOLE ■ STORM CB �■ STORM MANHOLE NOTE THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES IS SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. EXISTING GRADE INFORMATION IS APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY EXISTING GRADES AND NOTIFY ENGINEER OF ANY DISCREPANCIES BEFORE COMMENCING WORK. CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO CONFIRM EXISTING UTILITY AND GRADE INFORMATION. CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 DATE: CARL'S J R- H I LLCREST SQUARE 1 /15/08 for FIELDBOOK: CARL KARCHER ENTERPRISES, INC. PAGE: DRAWING N0: 4525 NE 4th Street, Renton, WA 98059 C 1 -3- GRADING & DRAINAGE PLAN [SHEET: OF: 6