Loading...
HomeMy WebLinkAboutWWP2703451.10POR OF THE NE 1/4 OF THE SE 1/4 & THE SE 1/4 OF THE NE 1/4, ALL IN SEC. 10, TWP. 23 N., RGE. 5 E., W.M. 0 U C; T �M 5 w x 1-k 3„ 38" MIN. WIDTH WHITE POST 62" II li lI I -I I I 24" SEWER MANHOLE MARKER POST SEWER MANHOLE MARKER NOTES: SEWER MANHOLE MARKER POST SHALL BE EQUAL TO CARSONITE UTILITY MARKER SEWER MANHOLE MARKER POST TO BE USED FOR SANITARY SEWER MANHOLES IN 'UNIMPROVED AREAS. SEWER MANHOLE MARKER POST SHALL IDENTIFY THE MANHOLE AS "SANITARY SEWER". 6.- — 404.2' PUBLIC WORKS SEWER MANHOLE MARKER POST DEPARTMENT N : SEPTE'V? 2011 PROPERTY LINE S-10 � FUTURE 6" BUILDING SEWER PIPE BUILDING SEWER w z 2"x 4" STUD MARKING POST PAINTED TEE WITH 6" SIDE OUTLET �6"X6"X6" WYE } SURFACE CLEANOUT WITH WHITE MATH THE WORD "SEWER" STENCILED CAST IRON RING &COVER IN 3" HIGH BLACK LETTERS AND #6 WIRE oEAST JORDAN IRON WORKS WRAPPED AROUND THE STUD AND ( EXTENDED TO THE TOP OF THE STUD. of 2975 OR APPROVED EQUAL, a_SPECIFY 'SEWER" ON LID, SEE STD. PLAN 403.1 FOR 6" SIDE SEWER AND BUILDINC SEWER INSTALLATION) ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN LINES ARE AS FOLLOWS: A. VITRIFIED CLAY MAIN - CUT IN A NEW TEE USING FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL), B. CONCRETE MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL). C. PVC MAIN -- CORE DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) OR CUT IN A NEW TEE USING RIGID COUPLINGS. D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. 60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE, 1: 3:5 MIX CONCRETE BLOCKING GQ`yCFL 2% MIN SLOPE 6" SIDE OUTLET .TEE ��IHCRIZONTAL SEWER 6" MIN. MAIN SEWER MAIN CONCRETE BLOCKING ANGLE TYPICAL SIDE SEWER ELEVATION OF TEE AT MAIN OVER 25 ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. PUBLIC WORKS STANDARD SIDE SEWER STD. PLAN 406.1 DEPARTMENT INSTALLATION (SEWER MAIN TO PROPERTY LINE) SEPTEM13ER 2011 NT S =345 120 r� CITY OF RENTON Approved by: _�� Date: Approved by: Date: Approved by: Date: Approved by: Date: 1\ TRLAD ASSOCIATES 12112 115th Ave. NE Kirkland, WA 98034-6923 425.821.8448 425.821.3481 fax 800.488.0756 toll free www.triadassociates.net z� RICHARD A. TOMNONS PE PROJECT MANAGER MARK I HARRISON, PIS PROJECT SURVEYOR RICHARD A. TOAIKIHS PE PROJECT ENGINEER "FERY L COX ASL4 PROJECT LANDSCAPE ARCHITECT FIRST SUBMITTAL DATE: 7127107 SCALE: HOBIZ.:N/A YBR MIA PEER REVIEW: TOM MATT, PE 12/13/11 Q "f ONAL 1 j�!!5k,'2-- STAMP NOT VALID UNLESS SIGNED AND DATED JOB NO. 01- 047 SM7 NO. 10 OF 10 (C) 2012 TRIAD ASSOCIATES ak3�- psi � � 7,349��