CALL BEFORE YOU DIGS
1-800-424-5555
CALCULATED LAND AREA
123,808 S.F. OR 2.84 ACRES, MORE OR LESS
DATE OF SURVEY
FIELD SURVEYS BY BARGHAUSEN CONSULTING ENGINEERS, INC.,
CONDUCTED IN FEBRUARY 2006.
LO
Z
HORIZONTAL DATUM
Q
— BASIS OF BEARINGS
w
THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE
Q
Z
SOUTHEAST QUARTER OF SECTION 3, TOWNSHIP 23 NORTH,
>
RANGE 5 EAST, W.M., TAKEN AS NORTH 88' 12' 17w WEST,
v Q
BEING THE BEARING BETWEEN KING COUNTY SURVEY
o
CONTROL MONUMENTS 2802 (SE CDR SECTION 3) AND
2803 (S 1/4 COR SECTION 3), BASED UPON NORTH
�
Z
AMERICAN DATUM OF 1983 - NAD 83 (91) -
O
WASHINGTON STATE PLANE COORDINATE SYSTEM, NORTH ZONE.
j
VERTICAL DATUM
0
— BASIS OF ELEVATION
Z
NORTH AMERICAN VERTICAL DATUM OF 1988 - NAVD 88
THE BENCHMARK IS KING COUNTY SURVEY CONTROL POINT
NO. 2923, TAKEN AS 405.42 FEET.
LL
O
SPECIAL EXCEPTIONS
(TITLE REPORT NO. 1203407 BY CHICAGO TITLE INSURANCE
COMPANY DATED FEBRUARY 16, 2006)
1. EASEMENT TO PACIFIC TELEPHONE & TELEGRAPH REC.
NO. 1162865 - NO LEGAL - BLANKET
2. RESERVING MINERALS REC. NO. 342932, BLANKET
3. SENSITIVE AREAS NOTICE, RECORDING NO. 20020403001781, BLANKET
UTILITY CONFLICT NOTE:
CA UTION:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR
VERIFYING THE LOCATION, DIMENSION AND DEPTH
OF ALL EXISTING UTILITIES WHETHER SHOWN ON
THESE PLANS OR NOT BY POTHOLING THE UTILITIES
AND SURVEYING THE HORIZONTAL AND VERTICAL
LOCATION PRIOR TO CONSTRUCTION. THIS SHALL
INCLUDE CALLING UTILITY LOCATE ® 1-800-424-5555
AND THEN POTHOLING ALL OF THE EXISTING UTILITIES
AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY
VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS
OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT
GUARANTEED AND ARE SUBJECT TO VARIATION.
Notice Required
Contractors sholl notify operators who maintain underground utility lines in
the area of proposed excavation or blasting at least two business days, but
not more than ten working days prior to commencement of excavation or
demolition in accordance with RCW Title 19. Names and telephone numbers
of the operators of underground utility lines in this project appear below.
These numbers sholl also be used to serve in on emergency conditions as
required.
CITY OF RENTON
Sanitary Sewer
KING COUNTY WATER DISTRICT #90
Water District
PUGET SOUND ENERGY
Gas Company
(425) 430- 7200
Phone
(425) 255-9600
Phone
(800) 321-4321
Phone
PUGET SOUND ENERGY (800) 321-4321
Power Company Phone
Call Before You Dig DIAL —A —DIG 1-800-424-5555
Notes
1. The Developer is required to notify the Dept. of Development and Environmental
Services Inspection Unit, three days prior to the beginning of construction
for a preconstruction conference and specifically request inspection
before beginning:
A. Installing of siltation and erosion control measures
B. Clearing and grubbing
C. Earthwork
D. Installation of any underground utility
E. Before placing subbase, base or paving surface
F. Installation of any forms or placing any concrete
2. A permit must be obtained from the office of the Resident Engineer,
Washington State Deportment of Transportation, before any construction
is started on any existing state route.
3. A Hydraulic Project Approval (HPA) Permit must be obtained from the
Washington State Deportment of Fisheries prior to any work when required.
PLAT OF WINDSTONE DIVISION V
A PORTION OF THE E 1/2 OF THE SE 1/4 OF THE SE 1/4 OF SECTION 3, TOWNSHIP 23 N., RANGE 5 E., W.M.
KING COUNTY, WASHINGTON
..........
NE 17T H 8T
,
,
PARCEL:
_ __....032305.-9Q70
. ...............f
- CATEGORY 4
-- -- G.� WETLAND
`Q (FIELD LOCATED PER
2 CHAD ARMOUR & ASSOCIATES)
I ,
I J 1 795 SF
I
TRACT 'A'
SEASONAL
3 TYPE N
I ++ ` STREAM
.__..... .,._s I TRACT C
F r'
4 ;
5
_............ ...
9
6
,_//
�uF
10
. 1
PAI
032305-
+
V +
+ /
/
'B.
234
x
TRACT 'E'
/
SHEET INDEX
SHEET NO. TITLE
SS1 OF 3 COVER SHEET
SS2 OF 3 SANITARY SEWER PLAN AND PROFILE
SS3 OF 3 NOTES AND DETAILS
SURVEYED:
BCE
DESIGNED:
RJH
DRAWN:
RJH
1 COR COMMENTS DATED 7/2/08 AND REDLINES RJH 7/8/08 AS CHECKED::
NO. REVISION BY DATE APPR APPROVED
S U14(05 61
Vicinity Map
SCALE:
VERTIw , HORIZONTAL: D 11983/1991
HORIZONTAL: 1 .eo Y CITY OF
RENTON
ONE INCH DATUM
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
By:
Scale: N.T.S.
Date:
By: Date:
By. ,
PLAT OF WINDSTON DIVISION 5
SANITARY SEWER
COVER SHEF-�=��J
PL1 SAID /08
OF , A S, ll
�o 24661 0 ��
S T
S�0NA L
EXPIRES 6 11 p
3/24/08
PAGE:
DRAWING NO*
SS1 3
0 ,s--3465,-)1