HomeMy WebLinkAboutWWP2703473.141 z 0 w w CAST IRON TRAFFIC COVER ANGLE BRACKET EMBOSSED "GROUND ROD" (2 PER SECTION) 2 POLE WATERPROOF FUSE CONDUCTORS UP 3/8' DIA BOLTS MIN CAST IRON GRADE RING. FINISHED GRADE CORD GRIP HOLDER WITH 2-20A FUSES TO LUMINAIRE ANCHOR TO WALL ADJUST TO FINISHED GRADE J— BOX —�� BUSHING LIGHT POLE HANDHOLE 17/ GROUNDING LUG EQUIPMENT PRECAST CONCRETE BOX °a 1 /4" 00 EQUIPMENT GROUNDING s a° q,• GROUND CONNECTOR ° ° 9" MIN DIA. ° o°o° MOLDED CORD STAINLESS OR PLUMBING NUTS CP 3" GROUT FILL CONDUCTOR— SIZE 1/8" AIR SPACE BURNDY TYPE GAR, ° LEVEL FLOAT (GEMS SENSOR BOLTSTEEL(TYP) AFTER PLUMBING PER NEC OR CONDUIT SCHEDULE AS GD OR GK <° a MODEL LS-270 OR EQUAL WITH 12"Wx24"Lx24"D APPLICABLE (TYP) GROUND BUS z ° N BARE COPPER INTEGRAL MOUNT AND SPLASH MOUNT LEVEL FLOAT GUARD) ACTIVATION LEVEL SO IS 2 FIBERGLASS 1 1/2" STEEL CONDUIT ELL — INSULATED GROUNDING CONDUCTOR a INCHES ABOVE FLOOR LEVEL HANDHOLE ° - . e INSULATED BUSHING ` SUPPLEMENTARY EQUIPMENT GROUNDING GROUNDING BUSHING DRAIN ROCK - o°N e 6" BASE OF °°°° °° CONDUCTOR — SIZE DRAIN ROCK < .>° :oo < ° ,. PER NEC; WITH 3/8" 0 BOLT COMPACTED EARTH III =III = III =III =III = ° °° #1 AWG MIN (TYP) (2 PER SECTION) °o° =III=III =III=III=III a> `�' SUMP WITH SUMP PUMP (PUMP ° 6 #4 REBAR C� ° EQUAL SPACING 3/8 BOLT CONCRETE PAD—� III —III= III=III=III= a a NOT SHOWN FOR CLARITY) OR PROVIDE ANCHOR ° BOLTS PER r a 3 #3 TIES 0 12" (4 PER SECTION) REBAR CONDUIT NOTE: VAULT FLOOR MANUFACTURER'S RECOMMENDATION CONDUIT 20' MIN CU WIRE CONDUIT GROUND ROD 3/4"X10'—O" SWITCH SHALL OPEN UPON 24" DIA I (UFER GND) COPPER —CLAD STEEL 10 3/8" RISING WATER LEVEL. STRUCTURAL FILL REBAR 3/4"X8'—O" ALL AROUND MIN DIA GROUND ROD FREE STANDING AGAINST WALL LIGHTING POLE BASE 1 MAJOR EQUIPMENT ANCHORING 2 NOT USED 3 GROUND ROD & BOX INSTALLATION 4 FLOOD SWITCH DETAIL 5 NTS E10 NTS _ NTS E10 SCALE: NONE E10 NTS E10 GRADE ENTRANCE HEAD III f (THREADED CAP) ANTENNA BACKFILL TO 95% COMPACTION 'I WET WELL ROOF xry 3/8"�D STAINLESS STEEL EYEBOLT WARNING TAPE \�j\�j\\�// AND KELLUM GRIP (TYP PER Z 2" GRS CONDUIT-1 b o FLOAT CABLE) I N a a I I FLOAT SWITCH CABLE I SAND CONDUIT TO FLOAT SWITCH (TYP OF 4) CONDUIT CLAMP TYPICAL TRENCH DETAIL 7 SCALE: NONE E10 CORE DRILL THRU WALL, FILL GAP WITH CAULKING CONDUIT BUSHING SERVICE ENTRANCE f < ELBOW ANTENNA CABLE GROUNDING CLAMP �— GND WIRE AS REQUIRED TYPICAL FLOAT SWITCH DETAI 9 SCALE: NONE J Q e _ � ° d 4 a d a LIQUIDTIGHT ..< w X �LI1=1 FLEXIBLE III -III- ° CONDUIT LIMIT SWITC 1=111-III= ° a =III-1111 a (OPEN WHEN HATCH IS a OPEN) °_ BRACKET AN 1 /4" S/S 0 ANCHOR BOLTS FRONT VIEW ANTENNA MOUNTING DETAIL 6 SIDE VIEW NTS E10 INTRUSION SWITCH DETAIL 8 SCALE: NONE E10 J RECORD DRAWING These Record Drawings have been prepared based on information provided by the contractor and others. Kennedy/Jenks Consultants has not verified the 31892 accuracy or completeness of information provided to them and does not �'�1GIs1 1 warrant the accuracy or completeness of these Record Drawings. Users of �lO1VAL these Record Drawings assume all risk of loss resulting from their use. Kennedy/Jenks Consultants SURVEYED. DESIGNED: PAR SCALE. 1988 HORIZONTAL: NADD983/7997 �► AS NOTED CITY 0 � STONEGATE LIFT STATION REPLACEMENT DATE: 05-24-2010 P GLDBOOK: 32001 32nd Avenue South, suite 100 DRAWN R E f� T 0 �l Federal Way, WA 98001 GWM ONE INCH DRAWING NO: Roth Hill, LLC Tel 425.869.9448 www.rothhill.com Ph. 253-835-6400 RECORD DRAWING RFB 20 1 PAR CHECKED: AT FULL SCALE DATU M Planning/Building/Public Works Dept. ELECTRICAL DETAILS 2 E 10 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 Fax 253-952-3435 N 0. REVISION BY DATE AP P R APPROVED: NOT ONE INCH SCALESCC ALE ACCORDINGLY SHEEP: OF: � Q 42 r3:5-34733Y