HomeMy WebLinkAboutWWP2703473.15CONDUIT AND WIRE SCHEDULE w i 0 0 co 0 / 0 i Y Ir U / c� 0 z 0 0 0 n / U) 0 0 / Ln Ib N 0 C O 0 J / L0 ("I 00 z 0 L 0 / 0 0 06 0 O 0 / 0 0 / LL 0 0 N z 0 Cn Ir Lam, w Un W ROTFIHI LL Roth Hill, LLC Tel 425.869.9448 www.rothhill.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 NUMBER FROM TO SIZE POWER CONTROL SIGNAL COMMENTS POWER P-PSE UTILITY VAULT UTILITY TRANSFORMER CONDUIT AND MV CONDUCTORS BY UTILITY (PSE) P-SL UTILITY TRANSFORMER CT ENCLOSURE 4" 4 #600 KCMIL, #3G COORDINATE WITH UTILITY P-CT CT ENCLOSURE UTILITY METER BASE COORDINATE WITH UTILITY P-SE CT ENCLOSURE MOTOR CONTROL CENTER 4" 4 #600 KCMIL, #3G COORDINATE WITH UTILITY P-ATSA MOTOR CONTROL CENTER STANDBY GENERATOR 3" 4 #350 KCMIL, #3G P-PGEN MOTOR CONTROL CENTER PORTABLE GENERATOR PLUG 3" 4 #350 KCMIL, #3G MOTOR CONTROL P-P210 MOTOR CONTROL CENTER POWER JUNCTION BOX 2" 3 #1, #6G 2#14 P-P220 MOTOR CONTROL CENTER POWER JUNCTION BOX 2" 3 #1, #6G 2#14 HVAC P-EH1 LIGHTING PANEL L1 EH-1 ELECTRIC HEATER 3/4" 2 #12, #12G P-EF1 LIGHTING PANEL L1 EF-1 EXHAUST FAN 3/4" 2 #12, #12G P-CD LIGHTING PANEL L1 CD-1 CONTROL DAMPER 3/4" 2 #12, #12G INSTRUMENTATION P-MCP LIGHTING PANEL L1 MAIN CONTROL PANEL 3/4" 2 #12, #12G C-CONTROL MAIN CONTROL PANEL FLOATS JUNCTION BOX 1" 20#14 1#18 TSP LEVEL SWITCHES, LIT, INTRUSION SWITCHES C-GEN MAIN CONTROL PANEL GENERATOR CONTROL PANEL 3/4" 10 #14 C-MCC MAIN CONTROL PANEL MOTOR CONTROL CENTER 2" 50#14 C-ATSGEN MOTOR CONTROL CENTER GENERATOR CONTROL PANEL 3/4" 6 #14 S-FIT MAIN CONTROL PANEL FLOW TRANSMITTER 3/4" 1#18 TSP P-FIT MAIN CONTROL PANEL FLOW TRANSMITTER 3/4" 2 #12, #12G S-FE FLOW TRANSMITTER FLOW METER IN VALVE VAULT 3/4" VENDOR SENSOR CABLES P-VAULTS LIGHTING PANEL L1 VAULT LIGHTING AND SUMP PUMP 1" 4 #12, 2#12G VIA SWITCHES ON EQUIPMENT STAND C-VAULT1 FLOATS JUNCTION BOX VALVE VAULT 1" 8 #14 LIMIT SWITCHES, INTRUSION SWITCHES AND FAS C-VAULT2 FLOATS JUNCTION BOX WET WELL INTRUSION SWITCHES 3/4" 2#14 C-VAULT3 FLOATS JUNCTION BOX OVERFLOW VAULT INTRUSION SWITCHES 3/4" 2#14 C-SD MAIN CONTROL PANEL SMOKE DETECTOR 3/4" 2#14 C-DOOR MAIN CONTROL PANEL DOOR INTRUSION SWITCH 3/4" 2#14 MISCELLANEOUS MAIN CONTROL PANEL OUTSIDE ANTENNA 3/4" COAXIAL P-GENACC LIGHTING PANEL L1 STANDBY GENERATOR 3/4" 4 #12, 2#12G BLOCK HEATER AND CHARGER NOTE: WHERE ALLOWED AND WHERE CONTRACTOR CHOOSES TO GROUP CONDUCTORS IN A HOMERUN CONDUIT, THE HOMERUN CONDUIT SHALL BE SIZED SO THAT THE CONDUIT FILL DOES NOT EXCEED THAT ALLOWED BY THE NEC. LOAD SUMMARY EQUIPMENT NUMBER DESCRIPTION CONNECTED LOAD DEMAND FACTOR HP AMPERES KVA AMPERES PUMP 210 PUMP 220 TRANSFORMER 85 HP WET WELL PUMP 85 HP WET WELL PUMP TRANSFORMER 480-120/208 85 85 109 109 18.0 84 84 15.0 1.25 1.00 0.7 136 109 13 480/277V, 3-PHASE, 4-WIRE TOTALS: 258 PANEL-L1 208 /120 VOLTS, THREE PHASE, 4 WIRE BUS: 100A AIC: 101KA MAIN: 50A/3P MOUNTING: SURFACE CKT. NO. DESCRIPTION CONNECTED KVA TRIP AMPS/ POLES CKT. NO. DESCRIPTION CONNECTED KVA TRIP AMPS/ POLES A B C A B C 1 RECEPTACLES 0.1 2 /1 0 2 VAULT WETWELL LIGHTING U & G G 0 .4 2 /1 0 3 EF-1 EXHAUST FAN 0.6 20/1 4 GEN BATTERY CHARGER 20/1 5 MAIN CONTROL PANEL 1.5 20/1 6 GEN BLOCK HEATER 20/1 7 CONTROL BUILDING LIGHTING 0 5 20/1 8 EH-1 ELECTRIC HEATER 1.5 2 /2 0 9 S PARE 0 1 2 /1 0 1 0 H-1 ELECTRIC HEATER E ELEC C1.5 20/2 VALVE VAULT SUMP PUMP, P-230 0.711 20/1 12 HOTBOX 00 20/1 1 30 YARD LIGHT 1 2 /1 0 14 S PARE 0 0 20/1 15 VALVE VAULT RECEPT. 00 20/1 PHASE SUBTOTALS (KVA): 0.71 0.7 2.2 1.9 1.7 1.0 PHASE TOTALS (KVA): 2.6 2.41 3.2 TOTAL KVA: 8.2 KVA TOTAL AMPERES: 22 A LIGHTING FIXTURE SCHEDULE .SYMBOL DESCRIPTION CATALOG NO. VOLTAGE VA LAMP TYPE MOUNTING REMARKS F1 WRAP -AROUND, INDUSTRIAL, 2-LAMP, FIBERGLASS HOUSING, ACRYLIC DIFFUSER DMW-2-32-120-ES 120 96 T8 FLUORESCENT SURFACE LITHONIA F2 SUITABLE FOR CLASS 1 DIV 2 HAZARDOUS LOCATION. WALL MOUNT, WET LOCATION PD-070HP-12-K-W-1-C 120 70 HPS SURFACE (WALL) HOLOPHANE PREDATOR SMALL F3 POLE -MOUNTED HPS FIXTURE, ALUMINUM HOUSING. WITH PE CELL 1A-CCS17A5-150HPS120-DBP-A30 120 1150 IHPS I PRA14-A-DBP POLE KIM F4 SUITABLE FOR CLASS 1 DIV 1 HAZARDOUS LOCATION. WALL MOUNT PETM-070HP-12-SY-WL 120 170 HPS SURFACE WALL HOLOPHANE PETROLUME F5 WALL PACK, CUT-OFF, 10OW METAL HALIDE, ALUMINUM HOUSING, POLYCARBONATE DIFFUSER, WET LOCATION TWAC-100M-120-EP-DDB 120 1100 1 METAL HALIDE SURFACE (WALL) LITHONIA Kennedy/Jenks Consultants 32001 32nd Avenue South, Suite 100 Federal Way, WA 98001 Ph. 253-835-6400 Fax 253-952-3435 SURVEYED: SCALE: DESIGNED: AS NOTED PAR DRAWN: BBH 1 RECORD DRAWING RFB 7/20/12 PAR CHECKED: ONE INCH PAR AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY PAR VERTICAL NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM t j �6 'R CITY OF RENTON Planning/Building/Public Works Dept. S=347339 RECORD DRAWING These Record Drawings have been prepared based on information provided by the contractor and others. Kennedy/Jenks Consultants has not verified the accuracy or completeness of information provided to them and does not warrant the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loss resulting from their use. STONEGATE LIFT STATION REPLACEMENT ELECTRICAL SCHEDULES 31892 ONIAL 05-24-20101 PAGE: DRAWING NO: E11 39 42