HomeMy WebLinkAboutWWP2703473.31GqE 3-23-5
i
I
0
/
Cn
c�
0
z
0
v
0
0
/
c�
0
Co
N
0
0
in
J
/
N
00
z
CD
w
0
0
0
00
0
O
O
0
0
LL
w
Q
z
Li
J
II
C,
Al2
3
100' WETLAND BUFFER
EX. LIFT STATION -
AND FORCE MAIN
TO BE ABANDONED
(SEE SHT.C10 FOR
PLAN & DETAILS)
b
6 A5
A8
I I
i
A7
I
JA�2 30'
FLAGGED EDGE OF WETLAND
30'
A] �
A C T " A 99
I
Z
I I �
I L
O
W Z
5
0
LL
�� O
X
Q : �" Z
T F-
o U
UP ,
X I I
CHAIN LINK FENCE
I I
GENERATOR SET L
I� - ----- _-� \ PROPOSED I x
• _ TRANSFORMER'
I ---------------
•I r—T7----------
CONTROL e
I
x I I OVERFLOW
VALVE II
V BUILDING STORAGE VAULT VAULT
\ + IL
-- — ------ I 1
L— J
PROPOSEDGA
12" BYPASS \ + � ,- I I UP
Fob\ ;WET �, i CONNECT TO FRENCH
10' TEMP. CONSTR. °F\ WELL I
EASEMENT (TYP.) �s� " I DRAIN (SEE SHT. 8)
\ L — — x '� I
LANDSCAPINGV - x- t- w --w-
PER SHT. L1 \ _-
00
PROPOSED 12"PVC , 4, 8" 45' BEND MJxFL
"GRAVITY SEWER > I /♦ ( )
�♦ 8 22.5 BEND (FLxMJ)
e PERM. ESMT. (TYP.) �♦ W/ CONCRETE BLOCKING
— - Ex. 10' - / / ,(ROTATE VERT. AS REQUIRED)
DRAINAGE c, /
ESMT. P �� / �1 / 8" 45' BEND (MJxMJ)
5 C E
/ W
PROPOSED 8 PVC /. � � / CONCRETE BLOCKING
C900 FORCE MAIN /; (ROTATE VERT. AS REQUIRED)
6 SEE TYPICAL / b 4'WIDE
C9 TRENCH DETAILS ♦ /ARBOR WITH 8"
SOLID PVC 6
/.
T "STONEGA E
EX. 8' DIAM /♦ SIGN" 9
WET WELL
ELECTRICAL 6"CE / ♦ 80LF-6" 4
CONTROLS / /♦ 4"cE i W FRENCH DRAIN ll C9
J ' ,
6„CE 4 16i —PM — ♦ -h � x � :
♦ P < >
I 14'TALL
6"PM 6„C / B° J I ARBOR TAE / J i-
-/-1 / 6 C E ♦ N
♦N IW
RS w d—/
--- —
MAIN FORCE 69lX$„ �TEE
- _ EX. SEWER
- NE 26TH STREET I
8"PVC C900 -
------------------
FORCE MAIN TO --
BE INSTALLED BY _--
1�7
J
z IPc
ZI
1 14 —
CONTRACTOR SHALL POTHOLE
TO DETERMINE LOCATION AND
DEPTH OF FORCE MAIN PRIOR
TO FORCE MAIN CONSTRUCTION
L -- - WV(2)
I
- R \ CS
OTHERS �� �� , I _.� I :
2'TALL LAUREL CONC 2'TALL LAUREL 2\
DRIVE
Roth Hill, LLC Tel 425.869.9448 www.rothhill.com
11130 NE 33rd Place, Suite 200 Bellevue, WA 98004
BRO
r�41 of WA
37847
"SSIONAL
y�D.S,,
wAsN1�'�'��
�r
45274
��GISTE��
SIONAL E�
IiI�I I FH•
20 0 20 40
SCALE IN FEET
NOTES:
1O WATER NOT LOCATED WEST OF THIS POINT.
0 WATER NOT LOCATED NORTH OF THIS POINT.
O3 MEGALUGS REQUIRED ON ALL MJ FITTINGS.
® MANHOLE COATINGS SHALL BE PER SPECIFICATIONS. EXTERIOR SHALL
BE WRAPPED WITH WRAPID SEAL OR APPROVED EQUAL.
S-341305
�v41� aF wASN/
4re r�,
37847 4
ISTEg����
�SSIONAL E�
FOR CONSTRUCTION
RECORDS ONLY
REVISED TO INDICATE
CONSTRUCTION RECORDS
REVISED BY: TERRY VAN WECHEL
DATE: JULY 20, 2012
CONTRACTOR: SHORELINE CONSTRUCTION
THESE CONSTRUCTION RECORD DOCUMENTS HAVE
BEEN PREPARED BY ROTH HILL, LLC. MOST FIELD
INFORMATION PROVIDED BY OTHERS. ROTH HILL HAS
NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS
OF INFORMATION PROVIDED BY OTHERS AND SHALL
NOT BE RESPONSIBLE FOR ANY ERRORS OR
OMISSIONS THAT MAY BE INCORPORATED AS A RESULT
OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.
SURVEYED: SCALE: DATE:
MJL VERTICAL: NAVD 198883/1 CITY O F STONEGATE 6BOOK: 10
AS NOTED HORIZONTAL: NAD 1983/1991 :�
DESIGNED: }� FlELDBOOK:
ELB/LDS ML R E N TO N LIFT STATION REPLACEMENT PAGE:
DRAWN:
TVW DRAWING NO:
ONE INCH DATU M
CHECKED: AT FULLSCALE Planning/Building/Public Works Dept. SEWER PLAN AND PROFILE C5
IF NOT ONE INCH
N 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY SHEET: 5 OF:42