HomeMy WebLinkAboutWWP2703473.33NE 3-23-5
GENERATOR SET NOTE:
co
cc
i
n
c�
0
z
0
0
0
C�
0
t`
Ln
00
Q)
.0
Y
Ln
N
z
w
L
1
0
0
0
0
w
Q
z
w
J
z
0
w
>
TRACT "A"
UP
_ BLACK VINYL COATED
WSDOT TYPE 3 CHAIN
.,TRACT 99 H 99 / °F LINK SECURITY FENCE PER
STD. PLAN L-20.10-00
INFILTRATION ENE
SYSTEM
100' WETLAND BUFFER _
I
I
w
c� GENERATOR SET
0
\
\\ I I I Z w a-
\� I I Q
o �- I I cn I
Q \ I I x Q I
w I \ I J I
w I �\
w I I \ \I CONTROL
Li I
�\ �\ BUILDING
\ 4 8" WET
C16 WELL VENT
w PER DETAIL
F
� P
1" POLY WATER
�� SERVICE LINE
AERIAL LIGHT MOUNTED ON
Q;
BLOCK WAL PER 3
GRADING PLAN & C`
DETAIL (SEE SHTS.
C8 & C9)
\ \ \ 8" VAULT VENT 4
_ PER DETAIL W/ C1
BOLLARDS PER
. OCOR DETAIL #H020
0 �
ASPHALT PAVING
r-------------------------------� p
-------------------------- 0
xo
I I I
I I I I
I � I
I
OVERFLOW
STORAGE VAULT
I I
i mi I I
L—---------------------------� I
WET �I ■■ iI
U
\ '�\ WELL /� ■ ■ VALVE z
VAU(0-
LT I Q
o
I Z
- a
ff__1 J
.,.
/ 211i' PVC SLEEVE
`1wON WATER
o POLE (SEE ELECTRICAL DWG.) / ♦ SERVICE LINE
z z 10' TEMP. CONSTRUCTION ESMT.-� —
J
Q
0
0
ROTPHI
Roth Hill, LLC Tel 425.869.9448 www.rothhill.com
11130 NE 33rd Place, Suite 200 Bellevue, WA 98004
`-A-PROPOSED /
48"0 MANHOLE
TRACT 99H 99 ;
STON ELATE
/ • 00 / 5"CE
/ ••
i �b l
/ :.Q6
/ / I 4-�/ /
AsQ
x
I
I
I
i
I
1
I
I
I
I
I
1
I
I
I
I
I
1
I
1
I
1
I
I
1
I
1
I
I i
1
I
z
w
w
Q
n
o �
w o
o 00
w
X
w
PROPOSED
20' WIDE DOUBLE
i GATE PER WSDOT
STD. PLAN
L-30.10-00
1
I I
1
fEXACT LOCATION OF
WATERMAIN UNKNOWN.
POTHOLE TO VERIFY
N ---w— LOCATION OF WATERMAIN
I
I,
A fl nrm\ A!\r
I
CONNECTION
1" WATER SERVICE PER i9
KCWD#90 STD. DETAIL \, 9
I
RELOCATE EXISTING
UTILITY BOX
BEHIND SIDEWALK
I
I
I
1
I
1
I j
I
I
I
I
I
I
I
I
I
I
I
1
I
1
1 :
I
1
I
I
I
1
I
I .
I
I
1
I
I
I
I
I :
I
I
I
I -
1 :0
I /
I
I
I
I
I
I
I
I
I
UPI
I -
I •
I .•
I
1
I
I
I .
I
I
I
I
I
I
I
I
I
I
I
I
I
I :
I
I
I
I
I �
i
1 I
C
o .
I
I :
I
I
I
I ,
I
I
I
a_
CI
S 347307
10 0 10 20
SCALE IN FEET
THE GENERATOR SHALL HAVE A SUPER -CRITICAL SOUND
ATTENUATED MUFFLER. SOUND ATTENUATION SHALL LIMIT THE
GENERATOR NOISE, INCLUDING EXHAUST, TO 45 dba AT THE
WEST PROPERTY LINE, ACCOUNTING FOR THE SCREENING
WALL. GENERATOR SET SHALL HAVE INTEGRATED SUB -BASE
DIESEL FUEL TANK, WITH VOLUME SIZED TO PROVIDE
OPERATION OF THE GENERATOR UNDER FULL LOAD
CONTINUOUS FOR 24 HOURS MINIMUM. THE FUEL TANK SHALL
BE A UL-LISTED UNIT WITH SECONDARY CONTAINMENT, AND
SHALL HAVE A DUAL -WALL TANK OR EQUAL. GENERATOR SET
SHALL MEET LATEST IFC REQUIREMENTS, INCLUDING VENTING.
L BROW
w41� of wa811J
d� 37847 w�
�GISTEg�
�SSI0 E �
FOR CONSTRUCTION
RECORDS ONLY
REVISED TO INDICATE
CONSTRUCTION RECORDS
REVISED BY: TERRY VAN WECHEL
DATE: JULY 20, 2012
CONTRACTOR: SHORELINE CONSTRUCTION
THESE CONSTRUCTION RECORD DOCUMENTS HAVE
BEEN PREPARED BY ROTH HILL, LLC. MOST FIELD
INFORMATION PROVIDED BY OTHERS. ROTH HILL HAS
NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS
OF INFORMATION PROVIDED BY OTHERS AND SHALL
NOT BE RESPONSIBLE FOR ANY ERRORS OR
OMISSIONS THAT MAY BE INCORPORATED AS A RESULT
OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.
.3c