Loading...
HomeMy WebLinkAboutWWP2703473.433 Q I 0 0 r- 00 00 0 0 U I Y 0 U i U) 0 0 z 0 1= U 0 0 ry n 0 i Ln 00 0 O 0 U) J i Ln N 00 N z 0 w 0 i 0 0 C6 0 0 0 i LO 0 0 w Q z W J_ LI 0 0 N z 0 U5 ry w 0 ry w C� N DOOR SCHEDULE DOOR FRAME ASSEMBLY REMARKS N0. SIZE WIDTH x HEIGHT TYPE MAT. MAT. DETAILS (SEE NOTE 1 BELOW) HARDWARE RATING HEAD JAMB SILL 1 PAIR S-2" x 8'-4" A H.M. H.M. 1 2 3 1 - DOOR INSULATION FACTOR: DOORS SHALL HAVE A U VALUE OF 0.6 OR LOWER DOOR TYPES DOOR NOTES 1. DOOR DETAILS ARE ON SHEET A3 UNLESS OTHERWISE NOTED. DOOR ABBREVIATIONS HM = HOLLOW METAL FINISH SCHEDULE ROOM FLOOR BASE WALL CEILING CEILING HEIGHT REMARKS NO. NAME OF ROOM OR SPACE MATERIAL FINISH MATERIAL FINISH 101 CONTROL BUILDING CONCRETE CONCRETE GYPSUM BOARD © GYPSUM BOARD © VARIES FINISH NOTES PAINT SYSTEMS: SEE SPECIFICATIONS SECTION 10.09900 FOR PAINTING SYSTEMS INDICATED IN THE SCHEDULE SYSTEM A = GLOSS FINISH SYSTEM B = SEMI -GLOSS FINISH SYSTEM C = EGGSHELL FINISH 1. PAINT ALL HOLLOW METAL DOORS AND FRAMES PAINT SYSTEM A& 2. PAINT ALL EXPOSED EXTERIOR AND INTERIOR STEEL PAINT SYSTEM AO INCLUDING: • METAL FABRICATIONS • SHEET METAL FLASHINGS THAT ARE NOT FACTORY FINISHED • ROOF ACCESSORIES THAT ARE NOT FACTORY FINISHED. 3. ALL EXPOSED INTERIOR & EXTERIOR CMU AND CONCRETE SHALL HAVE CLEAR WATER RESISTANT SEALER, SEE SPECIFICATION 10.07190. 4. SEE DRAWING A2 FOR CMU AND ROOF COLORS. CODE SYNOPSIS BASED ON THE 2006 IBC BUILDING USE CONSTRUCTION OCCUPANCY ACTUAL HEIGHT AREA FIRE ID N0. NAME TYPE SPRINKLE TYPE SEP. ADA FEET STORIES ACTUAL SQ. FT. ALLOWED CONTROL 15,500 1 BUILDING E-1 NONE NO V-B 15 1 240 SF PER NO FLOOR ROTF'ril LL Kennedy/Jenks Consultants 32001 32nd Avenue South, Suite 100 Federal Way, WA 98001 Ph. 253-835-6400 Fax 253-952-3435 CMU SCREEN WALL, SPLIT —FACE FINISH BOTH SIDES .i'—n" MIN i-I FAR o 2'-8 I I I I I I I Ii fO DOWNSPOUT I I I I I I I I I LINE OF ROOF OVERHANG ABOVE —� I I I I I I I I I I I I L-------------- CONTROL BUILDING 101 CONC. PAD O z I oo Q — o I I :2W q)_ q N c') O Q I ACOUSTIC LOUVER, i I 2'-0" x 2'-0" ---------------------------------------- — DOWNSPOUT A 1'-0" 1 INCH R-7 RIGID ROOF INSULATION R-30 BATT ROOF INSULATION 5 612 � A3 T.O. CMU \ 5/8" GYP BOARD SPLIT -FACE CMU I I I I I I I I ELECTRICAL NOTES PANELS I I I I I I 1. ALL DIMENSIONS ARE TO FACE OF CMU UNLESS NOTED OTHERWISE 6" HIGH x 12" WIDE STARTER I I I CURB I I I I ` I T.O. SLAB LEGEND A3 ODOOR IDENTIFICATION TAG, SEE DOOR SCHEDULE 101 ROOM IDENTIFICATION TAG, SEE FINISH SCHEDULE CMU WALL S=34731 1 48" 36" 24" 12" 0 2' 4' 6' 8' SCALE: 1 /4"=1'-0" PLAN SCALE: 1 /4"=1'-0" TRUSS, SEE STRUC. DWGS PRESSURE TREATED 2x3 WOOD STUDS ® 16" O.C. PREFINISHED METAL ROOF 2'-0" TYP @ EAVES \ ACOUSTIC LOUVER 4 A3 OPP HAND SECTION A SCALE: 1 /4"=1'-O" - GENERATOR ENCLOSURE R-10 RIGID FOUNDATION INSULATION SEE STRUCUTRAL DRAWINGS FOR GENERATOR PAD RECORD DRAWING These Record Drawings have been prepared based on information provided by the contractor and others. Kennedy/Jenks Consultants has not verified the accuracy or completeness of information provided to them and does not warrant the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loss resulting from their use. -�il�lll 7417 REGISTERED ARCHITECT DANIEL J. WRIGHT STATE OF WASHINGTON Roth Hill, LLC Tel 425.869.9448 www.rothhill.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 06; 5- 34>3l7