Loading...
HomeMy WebLinkAboutWTR2703480.512 z z O z w o w a_ Cc 1 Y z Q m Q Cm G J 0 CU C0 1 +00 STA. 1+00.00 IS LOCATED AT THE INTERSECTION OF THE 3 - - eENTERLMdE OF -SW 7TH--- - - -- M a S EET AND THE PROJECTS �5l� o I WESTERN BOUNDARY LINE a. p ° 32.16' NO TRUCK 18" CPP IE-16.78' � X x 18" CPP IE=16.85' Civil Engineers Structural Engineers Landscape Architects Community Planners Land Surveyors Neighbors n I' CB 1680 RIM=24.48' 12" PP IE=14.49' (NW) O 12" PP IE=14.52 (S) 40 I x I I I I6 cD i� N x I I Y Z J Z_ I Q U I � x I Iw rn I� 0 z x 0 40' ACCES Eh 3 ENT PER REC. NOS. 7712 00 $t 940215207 C a P COLUMBIA BANK - RENTON THE NORTHWEST QUARTER OF SECTION 19, TOWNSHIP 23 NORTH, RANGE 5 EAST, WILLAMETTE MERIDIAN STA. 2+68.43, 18.27' RT CITY OF RENTON, KING COUNTY, WASHINGTON 8" WET TAP SEE STD. PLAN B115 ON SHEET C4.6 FOR CONNECTION FTAIL _ 1-8" TAPPING TEE PROVIDE 3/4" DOMESTIC 1-8" TAPPING VALVE (FLxMJ) WATER METER PER STD. DWG 1-CONC. THRUST BLOCK �coS� B106 ON SHEET C4.5 �5p� STA. 2+68.47, 42.00' RT Li 1-8" GATE VALVE (MJxFL) " " 15p� 15p� -----1=8 x4 IREDIICE (FLxWJ) -- ---- -- ---- - --------- - - - - - - F - --- --- --- ----- - - -- - ---- -- °0 3+00 -, - _-4+�0- - g �__ - - -_ N89'10'29"W 1339.26' _-_--: - 5+00 o 6+00 ED DDCVA IN VAULT WITH PIV & FDC, SIZE TO - o BE DETERMINED BY FIRE SYSTEM DESIGNER, + 00 SW 7TH STREET -- SEE STD. PLAN B098.1 ON SHEET C4.5 STA. 4+12.07, 82.51 RT - 0 w EXISTING 12" WATER W - - w --- -- - r /} L r 1 ., 25 C I of a r 4" SPRINKLER SUPPLY -------- 3 SIZE TO BE CONFIRMED --BY TIRE_ SYSTEM 3 DESIGNER JIMfI tIJOV RIM=LJ.. 1� ALK 24" CPP (NW) IE=16. -- - -- - - ---- 1IN 24" CPP (S) IE=16.7, -,----EXISTING FIRE HYDRANT S6 --- 12" CPP (SW) IE=17.. L1 LI - L PROVIDE 5" STORZ FITTING 15 LEASE PARCEL LINE 5 < S8910'29"E PROVIDE 405.00' WATER METER PER STD. DWG c6 1581 RIM=2422' EET C4.5 _ 25 12" CPP (W) IE=20.02' 2(E) IE=20.23' PROVIDE DCVA PER STD. DWG. 12" CPP (NW) IE=20.1' 2S B101 ON SHEET C4.6 U D 3/ RPBV P,ER STD. IE = 19.87 (EXST- EXISTING FIRE HYDRANT IE = 20.04 (6-SW) PROVIDE 5" STORZ FITTING OVERBUILD ON EXISTING 8" SEWER, CONTRACTOR SHALL POTHOLE EXST. SEWER TO CONFIRM LOCATION AND DEPTH RIOR TO BEGINNING SEWER CONSTRUCTI a a < ° ° a ° 5NU IKUUK�) a STOP r��WL p NO UCKS� � L'�JL'-� >' 3 a rM - z to C4.G. B11 -ON SHEE N . .� 3/ " D S11C 25 % 'PO -- SU PLY, COORDINATE P01 OF ONNECTION WITH - _ " - C - -� --- - PLUMBING CONTRACTOR SSMH 1 6 RIM- .99' _- - _ -SDR8LF6 PVC �L �+ 8„ Pv (E,W,S - -� SD 35 2.00% 'o Cc L=20. DEMOLISH EXST. SEWER STA. 4+06.64� I OWS & WEST WEST OF NEW SSHM#1 87.92' RT --- o _ COORDINATE SEWER SERVICE POINT OF - __ RIM=25.70 CONNECTION WITH PLUMBING CONTRACTOR IE=20.17 - - 3 ColumbiaBank 1 3 ' W W W COORDINATE FIRE SUPPLY POINT OF ---- __- - -- - CONNECTION WITH SPRINKLER CONTRACTOR uu W i IP p � CB# 1751 RIM= 25.04' � 0 24" CPP (S) IE=17.32' 18" CPP (SW) IE=17.14 8" PVC (S) IE=20.86' a 1856 RIM= 49' 12" PVC (NE) IE-17.18' 12" (S) IE=16.44' 18" CPP ) IE=16.71' 12" PVC (N- ) IE=16.91 CB# 1781 RIM= 25.64' 1 " CPP (NE) IE=16.60' 12" CPP (NW) IE=15.69' 12" CPP (S) IE=15.81' T A C O M A S E A T T L E 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL 316 Occidental Avenue South, Suite 320, Seattle, WA 98104 206.267.2425 TEL RECORD NOTE 05/19/09 0 - I - � 384.00' - - S89'10'29"E 0 I 1 CB 1672 RIM=24.20' STRUCTURaL 12" CPP (N) IE=18.78' tidy " 1c 12" CPP (W) IE=18.13' w AH B L E S L1ND PLANNERS n n R GRAPHIC SCALE EXISTING FIRE 20 O 10 20 40 HYDRANT L I I I-i`�■■� THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, AHBL IS NOT RESPONSIBLE FOR ITS ACCURACY, OR ERROR OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THIS DOCUMENT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. AHBL JOB NO. 207533.10 GRAVEL _ __ -0- j CB #1653 RIM=24.08' 10 12" CPP (SW) IE=17.61 12" CPP (E) IE=17.79' x ASPHALT 0 K F� � � I ,. C0 ' pF WA �Sg�Nc 0� .► �SRac;ST SIGNAL NOTICE ALTERATION OF THIS DOCUMENT SHALL INVAUDATE THE PROFESSIONAL SEAL AND SIGNATURE. PUBLICATION OF THIS DOCUMENT DOES NOT DEROGATE FROM RESERVED OWNERSHIP RIGHTS IN IT. THIS DOCUMENT IS FOR USE ONLY FOR THE PROJECT IDENTIFIED IN THE TITLE BLOCK AND IS NOT TO BE USED FOR REPAIR, REMODEL OR ADDITION TO THAT PRO,ECT OR FOR ANY OTHER PRO.ECT. NO. ( IN FEET ) 1 inch = 20 ft. BENCHMARK CITY OF RENTON VERTICAL BENCHMARK NO. 1895 2" BRASS DISC WITH PUNCH ON CONCRETE MONUMENT IN CASE AT INTERSECTION OF SW 16TH STREET AND LIND AVENUE SW. PUBLISHED ELEVATION 25.70' rl GRAVEL / W L M / "*�10' ELECTRICAL EASEMENT REC. NO. 8010160469 (TYPICAL) 80 mono SURVEYED: ---- -- - -- JWB DESIGNED: GCH --- DRAWN: GCH CHECKED: - ---- SMC REVISION BY DATE APPR APPROVED: SMC SCALIE- 1 "=20' ONE INCH AT FULL SCALf IF NOT ONE INCH SCALE ACCORDINGLY 40 APLE 10" S ck 21.00' - N8910 29 W 40' ACCESS EASEMENT PER REC. NOS. 7719�11noAd b Gdn')1 F,)rna i I I~ cn Q S IQ I �2"C IF I 1 N /cJ I C � I MAPLE 8" 31 12" CPP (N) IE=21.30' 6" PVC (E) IE=21.28' in MI 0 Nt MAPLE 8" O ROW 1 MAPLE 8" O p MAj�PL^Ey,8" VERTTCAL. NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M I SSMH #1244 RIM=25.41' IE-19.26 (6"W) IE-19.21 (8"W) IE-19.16 (8"N) ASPHALT W-348005 CHECKED FOR COMPLIANCE TO CITY STANDARDS Date Date Date CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 CITY OF COLUMBIA BANK - RENTON RENTON Planning/Building/Public Works Dept. UTILITY PLAN DATE: 5/19/09 FIELDBOOK: PAGE: DRAWING NO: C4.1 SHEET. OF.1 C I�I�INN'�I1Ii A 1 II 1I