HomeMy WebLinkAboutWWP2703484.2w r) O U W J_ IJ F_ w z W U r O O MJ W L Z O II U.] (D D L In CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 10" 1„ 4 1 /2" 1„ 1„ R a� a 6" (TYP.) <: 8„ d: d A. ad < A n d 2" COMPACTED 1 da A CRUSHED SURFACING_ BASE COURSE - -' I COMPACTED SUBGRADE SECTION A -A TRENCH GRATE DETAIL NOT TO SCALE TRENCH DRAIN, SEE DETAIL THIS SHEET SEE PLANS CONCRETE - ENCASEMENT NEENAH R-4990 BX TRENCH GRATE OR APPROVED EQUAL A d a A 'Q °.. _° d..a A_ e A a d A, } a a • d .a • a 4 O A' ^ A 4d ° • A . A I • A a d A, • d d .. ° O A A a ° - d A a ° ea d ° p < A A d- a A 1 1/16" 1„ (6) 24' GRATES NOTE: L♦A MATERIAL CAST GRAY IRON ASTM A-48, CLASS 35B FINISH UNPAINTED 10" I_ -11� II-I-Ilil�lll,- III I I r� 8"0 PIPE o ADAPTER o • d. ° :. 8„0 PIPE TO STORM d. A A A d .d' . 8"0 TEE DRAINAGE SYSTEM ow TRENCH DRAIN CONNECTION TO STORM DRAINAGE SYSTEM NOT TO SOLE I 2'-0" 0 1 N STATE DISABLED PARKIN PERMIT REQUIRED 0 VAN ACCESSIBLE MUST CONFORM TO MUTCD STANDARD R7-8 METAL SIGN; BOLT TO PIPE COLUMN "VAN ACCESSIBLE" MUST CONTAIN WORDING: SIGN BELOW "STATE DISABLED PARKING INTERNATIONAL SYMBOL PERMIT REQUIRED" WHEN REQUIRED GRADE 6" 7" ►NAIW7: 1. PROVIDE SYMBOL IN ALL HANDICAPPED PARKING STALLS INDICATED ON SITE PLAN. 2. PROVIDE SIGN AT ALL HANDICAPPED PARKING STALL INDICATED ON SITE PLAN, WIDE PAINT RIPE TRAFFIC IE WHITE 2" SCHEDULE 40 GALV. PIPE THREADED ONE END WHEN SIDEWALK IS PRESENT, EDGE OF SIGN SHALL BE LOCATED ADJACENT TO BACK OF SIDEWALK, WHEN THERE IS NO SIDEWALK OR WHEN THERE IS A PLANTING STRIP BETWEEN CURB AND SIDEWALK, EDGE OF SIGN SHALL BE LOCATED 1.5 FEET FROM FACE CURB. - o d a\ d\ o \d \a d E ° da °I \ -- d d \ d d a \ 2" THREADED COUPLING d\ -° SET FLUSH WITH FINISH \° \ GRADE + 1/16" o. CONCRETE - 4" WELDING STUDS WELDED TO EXTENSION 0 0 I fV N SIGN INSTALLED WITH HAWKINS U-BRACKET MODEL NO. M2G-C2B OR EQUIVALENT 2'-2" SCHEDULE 40 GALV. PIPE (EXTENSION) THREADED ON ONE END r HANDICAP SIGN HANDICAP SYMBOL WHITE PAINT STRIPE (TYP) 9,-0" 5' MIN TYP HANDICAP STALL DETAILS 8' MIN NOT TO SCALE (VAN ACCESSIBLE) CONSULTING ENGINEERS LLC 33915 1 st Way South #200I ® I + I lj4�f I Federal Way, WA 98003 FEDERAL WAY (253) 538-6113 Bo1HE1L (4253 415-8144 www.eamcivii.com FlIM�ga Sae 962-25M Civil Engineering Land Surveying Land Planning N 0. Public Works I Project Management I Landscape Architecture SURVEYED: SI-ALE: N/A DESIGNED' DRAWN: Esm c:HE KED i1:SM REVISION BY DATE APPR APPROVED: GENERAL NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE AND DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 3. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 4. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN NECESSARY PERMITS, CONSTRUCTION EASEMENTS AND RELEASES. 7. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER IN THE EVENT OF DISCOVERY OF POOR SOILS, STANDING GROUND WATER OR DISCREPANCIES FROM THE PLANS IN GRADES, LOCATIONS AND CONSTRUCTION OF UTILITIES, STRUCTURES, AND OTHER EXISTING CONDITIONS. 8. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 3. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. DRAINAGE NOTES 1. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE AND WATER UTILITY SECTION, 2. A STORM DRAIN PIPE SHALL MEET THE FOLLOWING REQUIREMENTS: A) PLAIN CONCRETE PIPE CONFORMING TO THE REQUIREMENTS OF AASHTO M 86, CLASS 2. B) REINFORCED CONCRETE PIPE CONFORMING TO THE REQUIREMENTS OF AASHTO M 170. C) PVC PIPE SHALL CONFORM TO ASTM D 3034-73 SDR 35 FOR 4' THROUGH 15" DIAMETER PVC PIPE, AND SHALL CONFORM TO ASTM F 679 FOR 18" THROUGH 27" DIAMETER PVC PIPE, WITH JOINTS AND GASKETS CONFORMING TO ASTM D 3212 AND ASTM F 477. D) DUCTILE IRON PIPE CONFORMING TO THE REQUIREMENTS OF ANSI A21 .51, AND AWWA C 151, THICKNESS CLASS AS SHOWN ON THE PLANS. E) POLYETHYLENE SMOOTH WALL PIPE PER ADVANCED DRAINAGE SYSTEMS (ADS) N-12 CONSTRUCTED PER THE STANDARD SPECIFICATIONS 7-04. SANITARY SEWER NOTES 1. THE CONTRACTOR SHALL FIELD VERIFY LOCATION AND ELEVATION OF THE POINT OF CONNECTION PRIOR TO CONSTRUCTION. 2, THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 3. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 4. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50. 5. TESTING BY AIR OR WATER EXFILTRATION IS REQUIRED ON ALL SEWERS INCLUDING DRY LINES, AND VACUUM TESTING IS REQUIRED ON ALL MANHOLES. 6. THE STANDARD VERTICAL SEPARATION FOR WATER LINES IS 3 FEET ABOVE THE SEWER LINE AND 1.5 FEET FOR ALL OTHER UTILITIES (SEPARATION SHALL BE MEASURED FROM THE OUTER WALL OF THE PIPES). CONCRETE ENCASEMENT WILL BE ALLOWED FOR WATER MAINS CROSSING AT LESS THAN 3 FEET BUT NO CLOSER THAN 1.5 FEET. FOR OTHER UTILITIES A 0.75 FOOT CLEARANCE WILL BE ALLOWED. IF STANDARD CLEARANCES CANNOT BE OBTAINED, THEN EITHER THE SANITARY SEWER SHALL BE CONCRETE ENCASED OR CLASS 52 DUCTILE IRON PIPE SHALL BE USED. IF THE PIPE IS ENCASED, IT SHALL BE ENCASED 10 FEET ON EACH SIDE OF THE CROSSING. IF CLASS 52 DUCTILE IRON PIPE IS USED FOR THE SEWER NO TRANSITIONING TO OTHER PIPE MATERIALS WILL BE: ALLOWED BETWEEN MANHOLES. 7. THE MINIMUM HORIZONTAL SEPARATION BETWEEN SEWER AND WATER MAINS SHALL BE 10 FEET. SEPARATION SHALL BE MEASURED FROM THE OUTER WALL OF THE PIPES. 8. THE MINIMUM LENGTH OF CONCRETE ENCASEMENT SHALL BE 20 LINEAR FEET. 9. IN UNIMPROVED AREAS, A MANHOLE IS TO EXTEND A MINIMUM OF SIX (6) INCHES AND A MAXIMUM OF TWELVE (12) INCHES ABOVE FINISHED GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. WATER NOTES 1. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A RE -PRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS AND SPECIFICATIONS. THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 2. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 3, ALL CONNECTIONS TO EXISTING MAINS ARE TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 4. INSPECTION WELL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY-FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 5. ALL D.I. WATER MAINS ON PLAN SHALL BE CLASS 52. 6. PROVIDE MINIMUM 5' HORIZONTAL SEPARATION BETWEEN WATER MAIN AND ANY STRUCTURE OR TREE. VERTICAL: NAVD 1988 1.30 HORIZONTAL: NAD 1983/1991 ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY ::R C T �f� 0tRENTON Planning/Building/Public Works Dept �-lto S 34F4C ;L- PUGET SOUND BLOOD CENTER ;b1 t � �O�FFc/STER�OG\`�� P) t� sS�ONAL���� RECOMMENDED FOR APPROVAL BY: DATE:.'?' BY: DATE: BY: DATE: UTILITY AND SITE DETAILS AND NOTES mmialffla FIELDSOOK; B" PAI E: PAGE DRAWING N0: C1.05 SHEET: 5 9 NFAIA