Loading...
HomeMy WebLinkAboutWTR2703488.10�►1 G►1 •f�ftll� f. �► CONDUIT AND CONDUCTORS FOR 1/8" NEOPRENE GASKET AT INSULATOR AND FLANGE ANODE HANDH P5 ANODE HANDHOLE NO. 3, "A-3". SEE THIS SHEET FOR DETAILS. ANODE HANDHOLE NO. 4, "A-4". SEE THIS SHEET FOR % ANODE SWING GATE, ` DETAILS. HANDHOLE ' TYPICAL NO. 2, "A-2". / SEE THIS 4 4 f SHEET FOR 2 DETAILS. PROPOSED ALUMINUM , P6 / - VENT TO REPLACE 4 EXISTING VENT 4 \ j ANODE PROPOSED INNER 1 HANDHOLE GUARDRAIL ANODE P6 t NO. 1, "A-1". HANDHOLE j PROPOSED [ SEE THIS NO. 5, "A-5". 1 t SHEET FOR SEE THIS ELECTRICAL CABINET, DETAILS. SHEET FOR "EC-2" DETAILS. PROPOSED I j f- COVER ' 4 % PROPOSED ' .. tj OUTER GUARDRAIL ANODE HANDHOLE 4 / 1 NO. 6, "A-6". SEE / \ \ THIS SHEET FOR 11 DETAILS. / �m 4 4 ! 1 P5 `.� EXISTING ELECTRICAL CABINET ANODE HANDHOLE ` '"EC-1" REFERENCE CELLS N0. 7, "A-7". SEE HANDHOLE THIS SHEET FOR DETAILS. PROPOSED CATHODIC PROTECTION RECTIFIER COMPLETE ROOF PENETRATIONS PRIOR TO RESERVOIR INTERNAL RECOATING, TYPICAL. 1 /8" NEOPRENE GASKET, TYPICAL. PORCELAIN INSULATOR WITH HOT DIPPED GALVANIZED PIN, NUT, AND WASHER, TYPICAL. RESERVOIR CATHODIC PROTECTION PLAN WATER TIGHT CONNECTION CONDUIT(S) ENTRANCE WITH END BUSHING AT REFERENCE CELL HANDHOLE RESERVOIR ROOF LOCATE HANGERS SO OPERATOR CAN ACCESS f AND REPAIR ANODES AND REFERENCE CELLS FROM TOP OF HANDHOLE 0 HEADER CABLE HALF HITCH KNOT, TYPICAL. I _� ANODE WIRE SPLICED -' TO CONTINUOUS TO ANODES. SEE NOTE HEADER CABLE, SEE 6 THIS SHEET. NOTE 5 THIS SHEET. TYPICAL ANODE HANDHOLE DETAIL NOT TO SCALE PROPOSED REFERENCE CELL, "R-2" CONDUIT AND CONDUCTORS FOR 45-0" PROPOSED REFERENCE CELL,11 R-3 " 65-0" PROPOSED ANODE, TYPICAL i 50'-0" A-2,4,6 PROPOSED ANODE, EXISTING STRUCTURE } TYPICAL ELECTRICAL SENSING CABINET, 30'-0" "EC-1" \ TO PROPOSED REF LOAD CENTER, P7 I ® 12" — — — — — — — —I PROPOSED REFERENCE CELL, "R-1" CONDUIT AND CONDUCTORS FOR / STRUCTURE CURRENT SENSING RESERVOIR CATHODIC PROTECTION SCHEMATIC DIAGRAM_ NO SCALE POWER CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS NOTES P5 CATHODIC PROTECTION RECTIFIER REFERENCE CELLS HANDHOLE SEE SPECS. SEE SPECIFICATIONS. GALVANIZED STEEL CONDUIT P6 CATHODIC PROTECTION RECTIFIER REFERENCE CELLS HANDHOLE SEE SPECS. SEE SPECIFICATIONS. GALVANIZED STEEL CONDUIT P7 EXISTING ELECTRICAL CABINET, "EC-1", LOAD CENTER, "L1" CATHODIC PROTECTION RECTIFIER 3/4" 1(2) - #12, (1) - #12 GRD ELECTRICAL NOTES 1. PROPOSED REFERENCE CELLS CONDUIT. CONTRACTOR SHALL ROUTE REFERENCE CELLS CONDUIT TO PROPOSED CATHODIC PROTECTION RECTIFIER LOCATED IN EXISTING ELECTRICAL CABINET, "EC-1". CONTRACTOR SHALL SECURE PROPOSED REFERENCE CELLS CONDUIT BENEATH STAIRS TO EXISTING CONDUIT/CABLE SUPPORT BRACKETS WITH PROPOSED CONDUIT CLAMPS. SEE DWG NO. E02 FOR DETAILS. 2. PROPOSED ANODES CONDUIT. CONTRACTOR SHALL ROUTE ANODES CONDUIT TO PROPOSED CATHODIC PROTECTION RECTIFIER LOCATED IN EXISTING ELECTRICAL CABINET, "EC-1". CONTRACTOR SHALL SECURE PROPOSED ANODES CONDUIT BENEATH STAIRS TO EXISTING CONDUIT/CABLE SUPPORT BRACKETS WITH PROPOSED CONDUIT CLAMPS. SEE DWG NO. E02 FOR DETAILS. 3. PROPOSED CATHODIC PROTECTION RECTIFIER. CONTRACTOR SHALL LOCATE PROPOSED CATHODIC PROTECTION RECTIFIER IN EXISTING ELECTRICAL CABINET, "EC-1". 4. ANODE HEADER CABLE ROUTED UNDER ROOF, TYPICAL BETWEEN ANODE HANDHOLES. 5. CONTINUOUS LOOP HEADER CABLE, DO NOT CUT HEADER CABLE FOR ANODE CONNECTION. PROVIDE SLACK TO LIFT SPLICE OUT OF HANDHOLE. 6. ROUTE BOTH ANODE WIRES THROUGH HANGER AND CONNECT EACH ANODE SEPARATELY TO THE HEADER CABLE. REVISED TO CONFORM j TO CONSTRUCTION RECORDS pald 11�)J' JLt- 03122111 R1-12 ENGINEERING I C. DATE { 70'-0" H. w4 V 672 tSTISs 4-64 ti WAI. SIGNED: 04 /23 40 SIGNED: 04123110 PROPOSED ANODE, TYPICAL V� ♦ ` i Z EXISTING o RESERVOIR SHELL fII o cn cr aQ PROPOSED ANODE, TYPICAL �y W S 0 0 cl' = Z Oar.: a ?0 V Z V > W cn W M IRH2 ENGINEER[N(,,. ht1p:;//www.rh2.com mailbox@rh2.com 1.8J BFe 4 BOTHELL =z�= 12100 NE 195!FA VWENATCHEE w9.5 300 Simon Street, Suite 5 RICHLAND 509.9".5181 114 Columbia Point Drive, Suite C SILVERDALE aen 2021 NW Mhyr TACOMA _ -title Av- SCALE: SHOWN 6z� 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG _ 48 DWG NO ENGINEER DY E04 _ REVIEWED MLM 348810 DATE: MAR 23 2011 SHEET NO REVISED TO CONFORM TO CONSTRUCTION RECORDS NO. I REVISION CLIENT REN 0 MWB CMR 03/22/11 Jae NO 109-062 09 BY REVIEW I DATE FILENAME WHR-D-ELEC04 y x r r y C CD 1 � O b d [J