HomeMy WebLinkAboutWTR2703488.4_OWER LANDING PLATFORM SIDE PLATE, TYP OF 2 CLIMB PREVENTION / SHIELD DOOR u 12' - 0" 5-4} 7 5'-4)� a TYP VANDAL SHIELD ELEVATIO Yz"m HOLE FOR PADLOCIK 2" I 1" 1 /2" SHIELD LOCK TAB DETAIL so 6' = 1'-O" Y2` = 1'—C DOOR FRAMING OCK TAB, TYP OF 2, SEE A2 A3 iETAILS THIS SHEET SO SO S-6" N A SO1 2" --i 2" CLIMB PREVENTION SHIELD DOOR SHIELD LOCK TAB PLAN 'A 6" 1'-0" L2"x2"xY4"x0'-6", TYP OF 6. 2'-10" EXISTING TANK SHELL STEEL SIDE PLATE, 1'-C 12'-0" X 1/4", TYP. 0 L2"x2"x)4" FRAMING, CONTINUOUS AROUND PERIMETER OF SHIELD SIDE PLATES AND DOM. SLOT AT HINGE LOCATIONS AS REQUIRED. EXISTING LADDER VANDAL SHIELD PLAN Al 2" = 1'—O" SO S-0" CLR 6'-0" O.C. SPACING, TYP SWING GATE GATE LATCH W/ n LOCK HASP 2" RADIUS AT END OF RUN GATE HINGE, TYP 2. SPRING TO CLOSE. WALKING SURFACE TOE B1 ATTACHMENT DETAIL. ROOF VENT TO BE NEWLIN 24" 0 ALUMINUM CLOG -RESISTANT VENT OR APPROVED EQUAL. 1 ' 8" MIN EXISTING STEEL // VENT BODY NOTES: 1. ALL ADJACENT COMPONENTS OF CLIMB PREVENTION SHIELD COVER (INCLUDING ATTACHMENT BRACKETS, LOCK TAB, AND HINGES) AND ALL ADJACENT COMPONENTS OF CLIMB PREVENTION SHIELD DOOR (INCLUDING LOCK TAB AND HINGES) SHALL BE SEAL WELDED .AS SHOWN AND AT A MINIMUM WITH CONTINUOUS Y8" FILLET WELDS UNLESS NOTED OTHERWISE. ALL COMPONENTS TO BE COATED PER SPECIFICATIONS EXCEPT F HINGES. DOOR FACE PLATE, j' 2'-10" X 12'-0" X 1 /4" TYPE 304L STAINLESS STEEL HINGES (TYP OF 3) WITH Y4" MIN DIA. PIN, 4" OPEN WIDTH, V THICK PLATES. LEAVES OFFSET APPROX Y" TO ACCOMMODATE SHIELD BASE AND DOOR FRAMING. HINGES MUST HAVE 500—LB CAPACITY EA. HINGES SHALL BE PLACED TO ALLOW 180' DOOR SWING WITH MINIMUM HINGE PROFILE WHILE DOOR IS CLOSED. 1/4" CLR TO ROOF HANDRAIL 2" STD STEEL PIPE RAILS CONTINUOUS, TYP. 2" XX-STRONG GALV STEEL PIPE POSTS, TYP JLL l,....l ,,MENT DETAIL TWO -RAIL HANDRAIL NOTES: 1. CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING VENT, 2. ALL BOLTS TO BE STAINLESS STEEL ROOF VENT NOT TO SCALE ALUMINUM VENT BODY ALUMINUM PLATE Y8" NEOPRENE PAD BETWEEN ALUMINUM AND STEEL PLATES RESERVOIR ROOF D S01 TYP. 114 Y"O RB HOOK FOR LIFELINE ATTACHMENT. 2" CL RADIUS. TYP AT EACH VERTICAL POST. REVISED TO CONFORM TO CONSTRUCTION RECORDS 03 i22/11 RH2 ENGINEERING AC. DATE VW PL TOE BOARD, CONT. 6" PL 6x6xY". CENTER MAX POST ON PLATE j HINGED COVER, 3'-0" LENGTHS WITH Y4" GAP BETWEEN COVERS r i i `HANDRAIL POST 1 /4" i 1 /4" ROOF ATTACHMENT 2'-0" UNISTRUT ® 6'-0" O.C. MAX AND AS REQUIRED TO SECURE TO TANK. RESERVOIR SHELL f C3x5xO'-2" ® 6'-0" O.C. (TYP) CABLE TRAY_ NOT TO SCALE W 348804 1 /4" TYP. DOME ROOF PLATE SECURE WITH LOCKING MECHANISM M7C45.4 CHANNEL, EA SIDE. " SST BOLT TYP EA END OF UNISTRUT SUPPORT, TYP. NOTE: ALL CABLE TRAY COMPONENTS TO BE COATED PER SPECIFICATIONS ae'I � — —34 ` UJ REVISED TO CONFORM TO CONSTRUCTION RECORDS NO- REVISION SEAL, H. •�+ 0 WAS 1: 167 �$tGIST% jONAL SIGNED: 04 '23 '10 SIGNED: 04,123 /10 kt z.. ENUiNEERING INC. "'tQ. '. www.rh2. on-, mcilbox0rh2.com 1800. 2v._' BELLINGHAM 360.676.0 454 West Horton Rood BOTHELL 425,951 .54M 12100 NE 195th Street, Suite 100 EAST WENATCHEE so9.886.29m 300 Simon Street, Suite RICHLAND 509.946S1B1 114 _oJumbia Point Drive, Suite C SILVERDALE 360.876.7960 2021 NW Mhyre R,' TACOMA I SCALE: SHOWN 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG PLOT 48 DWG ENGINEEF JMC S02 REVIEWED: KLK MAR 22, 2011 "FF DATE: CLIENT REN 0 MWB CMR 03/22/11 Joe NO 109-062 09 BY REVIEW DATE FILENAME WHR-D-STRO1 It w m CD 0 N J 1 W 00