#3 BAR EACH CORI`
#3 BAR EACH SIDE
#3 BAR EACH
Botesch, Nash & Ha
Architects, P. S.
2727 Oakes Avenue • Everett, Washington 98201
Telephone 425-259-0868 • Fax 425-252-4334
6" BUILDING SEWER PIPE
TEE WITH 6" SIDE OUTLET
6" SIDE SEWER AND BUILDING SEWER
1:3:5 MIX
CONCRETE
BLOCKING
PROPERTY LINE
Z_
6'-0"
o
FUTURE
BUILDING SEWER
M
2"x 4" STUD SERVICE MARKER PAINT
w
UPPER PORTION WHITE ANS STENCIL ON
}
I-
SIDE WORDING "SEWER" WITH 3" HIGH
a
BLACK LETTERS. AND #6 WIRE WRAPPED
AROUND THE STUD AND EXTENDED TO THE
ry
TOP OF THE STUD.
0-
UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST
IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS
WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN.
PLAIN AND REINFORCED CONCRETE, DI PIPE AND Cl PIPE SEWER
MAINS ARE TO BE CORE DRILLED.
VITRIFIED CLAY PIPE SHALL BE CUT AND HAVE A NEW TEE
SECTIONED IN.
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PIPE.
\-6" SIDE OUTLET TEE
} SEWER
6" MIN. MAIN
CONCRETE BLOCKING ANGLE
OF TEE AT MAIN OVER 25
ELEVATION
��OG �NG
PN � gL
MP NGR�'(
GO 2% MIN SLOPE
HORIZONTAL
SEWER MAIN
TYPICAL SIDE SEWER ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE
A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
STANDARD SIDE SEWER INSTALLATION
N.T.S. (CITY OF RENTON STD. 3078)
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR
12"
PLAIN CONCRETE
ALL METAL PIPE
15"
CPSSP*
12"
(STD. SPEC. 9-05.20)
SOLID WALL PVC
15"
(STD. SPEC. 905.12(1))
PROFILE WALL PVC
15"
(STD. SPEC. 9-05.12(2))
CORRUGATED POLYETHYLENE
STORM SEWER PIPE
6" OR 12"
IOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12" HEIGHT
#3 BAR EACH CORNER
18" MIN
#3 BAR HOOP
l;A FCH BASIN TYPE 1
N.T.S. (CITY OF RENTON STD. B012)
110ZPerteet Inc.
425-252-7700 1 1-800-615-9900
2707 Colby Avenue, Suite 900
Everett, Washington 98201
M EMF
WAsy �s
44jQ
� Z
Y 40584
I EEC I
1 . As acceptable alternatives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 20". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4_ The frame and grate may be installed with the flange up or down. The
frame may be cast into the adjustment section.
�. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
All pickup holes shall be grouted full after the basin has been placed.
SEE NOTE 1
CITY OF RENTON PERMIT REVIEW
REVISION
1 /2" AND 2" WATER SERVICE DETAIL
CAUTION: VALVE BOX SHOULD NOT REST ON 10 11
PIPE. LATER COMPACTION IN AREA OF VALVE BOX
COULD CAUSE THE BREAKAGE OF THE SERVICE.
z <
3
io -4 n 1�.� N o
7
A - A DRILL 1-5/8" DIA. HOLE
FOR TOUCHREAD DEVICE
2-1/2" MIN. FROM NEAREST
T AND FRONT EDGE OF PIT LID
1
TYPICAL RIB
MATERIAL LIST FOR 2" SERVICE: METER LOCATED IN PLANTING STRIP
BETWEEN CURB & SIDEWALK
1. 2" tapped tee, on new water main.
2. 4" long X 2" brass nipple with threaded ends (MIPT).
3. 2" resilient seat gate valve with threaded ends, square operating nut,
and valve nut extension if required (dwg BR46/Page B090),
4. Two piece cast iron valve box. Standard 8" top section with regular
base section, length to fit, "lug" type cover. 2" brass bushing (MIPT x
FIPT.
5. 2 each 2" brass or bronze nipples 6" length, threaded ends. 2 each
2"-90' brass or bronze elbows (FIPT x FIPT).
6. 2" (MIPT) x compression fitting, Ford C84-66 or equal.
7. 2" soft copper tubing type K or brass nipples (MIPT x MIPT), length to
fit.
8. 2" threaded brass 90' ell.
9. 2" Customsetter with by-pass Ford: VBH 86-12B-11-77 (x 17-3/16"
), McDonald Brass: 30B715WDFF775 or Mueller B-1427-2", with flanged
angle ball valve and padlock wings on inlet, and angle check valve outlet,
ball valve on bypass with padlock wings. Customsetter shall have vertical
inlet and outlet.
10. Rigid meter spreader to be supplied and installed in meter setter by
contractor.
11. Water meter shall be supplied and installed by City of Renton upon
payment of all related water meter fee and satisfactory pressure and
purity tests.
12. 17"x30" Plastic meter box equal to Mid -States Plastics, Inc. BCF
Series MSBCF 1730-18 with 2" thick Ductile iron domond plate cover
18"x31" equal to Mid -States Plastics, Inc. MSCBC-1730-R with 1-5/8"
drilled hole for touchread pit lid, and meter read lid.
13. 2" coupling (compression x FIPT) with 2" plug (MIPT), Ford C-14-66
or equal. The property owner is responsible for any necessary
adaptation or extension of water service.
NOTE:
ALL METER BOXES INSTALLED IN CONCRETE OR PAVED
DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC
FOUNDARY.
EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH
SIDES OF METER BOX.
CITY
PIPING
w
z
l:1
z
J
J
IN UNIMPROVED
RIGHT-OF-WAY INSTALL METER
BOX AT PROPERTY LINE WITH
a
0
12" LONG COPPER TAILPIECE
a
0
a
a_
9" MIN.
12" MAX.
Z x
LEAVE EXPOSED 0
N U
12"
T BY PASS NOT ALLOWED
FOR IRRIGATION METERS
C'
CRUSHED ROCK
e
BASE TO SUPPORT
VAULT.
QUICK -JOINT
COUPLING x MIPT
CAST IRON OR DUCTILE IRON WATERMAIN
PRIVATE
PIPING
NOTE:
THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM
UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS
THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF
MORE THAN ONE RIB.
MATERIAL LIST FOR 1-1/2" SERVICE: METER LOCATED IN PLANTING STRIP
BETWEEN CURB & SIDEWALK
1. 2" tapped tee on new water main.
2. 4" long X 2" brass nipple with threaded ends (MIPT).
3. 2" resilient seat gate valve with threaded ends, square operating nut, and
valve nut extension if required (dwg BR46/page B090).
4. Two piece cast iron valve box. Standard 8" top section with regular base
section, length to fit, "lug" type cover.
5. 2" X 1-1/2" hex brass bushing (MIPT x FIPT). 2 each 1-1/2" brass or
bronze nipples 6" length, threaded ends. 2 each 1-1/2"-90' brass or
bronze elbows (FIPT x FIPT).
6. 1-1/2" (MIPT) x compression fitting, Ford C84-66 or equal.
7. 1-1/2" soft copper tubing type K or brass nipples (MIPT x MIPT), length
to fit.
8. 1-1/2" threaded brass 90' ell, for Ford L44-77 or equal.
9. 1-1/2" Customsetter with by-pass Ford: VBH 86-12B-11-66
(x 13-3/16"), McDonald Brass: 3OB612WDFF665 or Mueller B-1427-1 1/2",
With flanged angle ball valve and padlock wings on inlet, and angle check
valve outlet, ball valve on bypass with padlock wings. Customsetter shall
have vertical inlet and outlet.
10. Rigid meter spreader to be supplied and installed in meter setter by
contractor.
11. Water meter shall be supplied and installed by City of Renton upon
payment of all related water meter fee and satisfactory pressure and
purity tests. 17"x3O" Plastic meter box equal to Mid -States Plastics, Inc.
BCF Series
12. MSBCF 1730-18 with 2" thick Ductile iron damond plate cover 18"x31"
equal to Mid -States Plastics, Inc. MSCBC-1730-R with 1-5/8" drilled
hole for touchread pit lid.
13. 1-1/2" coupling (compression x FIPT) with 1-1/2" plug (MIPT), Ford
C-14-66 or equal. The property owner is responsible for any necessary
adaptation or extension of water service.
1-1 /2" & 2" DOMESTIC & IRRIGATION WATER SERVICE DETAIL
N.T.S. (CITY OF RENTON STD. 13107.1)
RECESSED
LIFT POCKET
12 Y4"
14"
-
12Y4"-
14" -
CAST IRON RING
NOTES:
1. 8" CLEANOUTS SHALL BE EASE JORDAN IRON WORKS, INC.
No. 3698 OR EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY.
2. IN UNIMPROVED AREAS, POUR A 1'-0" THICK, 2'-0" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER.
4. IN ASPHALT ROADWAYS, RESTORE AROUND CLEANOUT RING AND
COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36.
6" Or 8" CLEAN OU T
N.T.S. (CITY OF RENTON STD. B076.1)_
1 06 09 SURVEYED: SCALE:
VERTICAL: NAVD 1988
1 M=1 01 HORIZONTAL: NAD 1983/1991 CITY 0 F
DESIGNED:WE
DRAWN: GIW�G RENTON
1�11�1� ZONE INCH DATU M
CHECKED: ATATFULLSCALE Planning/Building/Public Works Dept.
APPROVED IF NOT ONE INCH
BY DATE APPR SCALE ACCORDINGLY
EME
CONCRETE
CLASS 3000
t TIGHT
W-349802
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
�W!W . •. _
FRONTIER BANK- RENTON, WASHINGTON
201 SOUTH THIRD STREET RENTON, WA 98057 FIELDBOOK
PAGE:
DRAWING NO:
C6.1
UTILITY DETAILS SHEET OF: