Loading...
HomeMy WebLinkAboutSWP2703531.18SECTION 32, TO 24 N, R 5 E, W.M. TM c J LO cy) N I () IRRIGATION MAIN LINE METER NITS SCHEDULE 40 ELBOW w CD z N PVC THREADED TEE AT MAINLINE '"" "m' ""rUN VALVE ASSEMBLY TO PRESSURE MAIN L_I, METER DOUBLE CHECK VALVE ASSEMBLY -1A II -I 1 -1 1-- A -- TYPICAL FLEXIBLE RISER NTS SIDE ELEVATION SECTION THROUGH MAIN LINE N FLUSH SH GRADE -E OR ELBOW PVC LATERAL LINE CHEDULE 40 STREET ELBOW TRIPLE SWING JOINT — SCHEDULE 80 40 STREET ELBOW FINISH GRADE VALVE BOX (10" ROUND) QUICK COUPLER — RAINBIRD 44 RC (2) STAINLESS STEEL CLAMPS TO STAKE SCH. 80 PVC NIPPLE W/3' #4 REBAR STAKE SCHED. 40 PVC ELBOW 360A PVC TRIPLE SWING JOINT — SCHEDULE 80 PVC PRESSURE MAIN SCHED. 40 PVC TEE OR ELBOW WITH THREADED OUTLET QUICK COUPLER 360"' PVC TRIPLE SWING JOINT ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS IPS FEMALE CONNECTION OF QUICK COUPLER. IRRIGATION MAINLINE, SIZE AS INDICATED ON PLAN c; INSTALL DETECTABLE MARKING TAPE 6" ABOVE PIPE. TAPE WIRE BUNDLE AT APPROX 20' OC VALVE WIRE BUNDLE NOTE: INSTALL WIRE BUNDLE BELOW PIPE CENTER AS SHOWN. CONTROL WIRE BUNDLE INSTALLATION NTS BOXES u iviin, E mCC DRAINING GRAVEL_ PROVIDE CLEARANCE ALL AROUND FOR FUTURE REMOVAL, TYP PVC 90A ELBOW PVC LINE MAIN NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2, THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING, THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE, A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS —CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. PVC THREADED ELBOW OR TEE A I n T r VALVE BOX WIRE LOOP - CONTROL WIRES AUTOMATIC CONTROL VALVE FINISH GRADE SCHED. 80 PVC. NIPPLE, DIA. OF VALVE, MIN. 2" LONG, EA. SIDE OF AUTOMATIC VALVE SCHEDULE 80 REDUCER (SxTH), SCHEDULE 80 UNION, TYP. -PVC LATERAL LINE BRICK SUPPORTS, TYP. EACH CORNER 4" MIN. GRAVEL BACKFILL FOR DRAINS ONLY ONE (1) VALVE PER VALVE BOX SEAL ALL THREADED JOINTS WITH TEFLON TAPE ON MALE THREADS ONLY. AUTOMATIC CONTROL VALVE STATE OF WASHINGTON REGISTERED LANDCAPE ARCHITECT ORIGINAL PLANS DESIGNED & STAMPED BY CALVIN JORDAN, CERT NO.69 AS —BUILT SURVEY BY: EVAN WAHLSTROM, PLS#44651 (INFORMED LAND SURVEYING) Imilm, Calvin ordlaint Associa-tes, hnc ARCHITECTURE URBAN PLANNING LANDSCAPE ARCHITECTURE 15049 NE BEL/RED RD BELLEVUE, WA 98007 Fax (425) 643 4607 Tel (425) 643 3123 E—Mail: architects®cja—inc.com QUICK COUPLER DETAIL DOUBLE CHECK VALVE ASSEMBLY —BU LT NTS NTS RR GAT ON DETALs AS N.T.S. :BE- 3 5 3 1 18 - "°"''"''" CITY OF 2/02/11 B.P.B. LAKE WASHINGTON BLVD NORTH RENTON wm C,,,K 011%STORMWATER AND WATER MAIN 011111111111" NIX C.° amp °ATOM Public Works Dept. IMPROVEMENTS 27 NO. REVISION BY DATE APPR m"v B.P.B. "27 0"27 �