Loading...
HomeMy WebLinkAboutSWP2703617.2a �H � O M zap 1 �W� ww�~ 1 O�b ww w� M AD N I r I I NO w Z J 0 20 4C� Of Cl- Scale in Feet ' I #306 I 1 1 N V Q EXISTING ROW W I LAWN W t/) w__ C 00 • W LO F-- S CO W Z LAWN EXISTING ROW 7_ �a r #305 N U Q .�Eo O N Cn C J ' O O O Cn W QL J 0 p I o QI x � I N N� I I U � oX I � I O m� k o Cl) w o w ,Y„ wog w Q_J U w o I F� o Y I i o oo, � w� i U o w #312 w Ld w Z EX SDMH 01- w t #318 � #402 #408 PLUG AND ABANDON CD EX 12 N, 12 SE & 8 SW I I I N 177924.52 E 1313044.62 CONNECT NEW STORM DRAIN PIPING 3� =o OFFSET 23.17' RT i m U U Z O U 1777V ccnnALJ I w� Z J Uj a 0 Of a W z - + +I CD o 0 z U U) N c`? z �r m� w D o (D " EX 12" CONC SD z C7 U c� Z z EX GRADE Y Y co M Y Q o Y (BEYOND NEWS ) o L E o z I o z AT C/L PIPE z o = z o = J z Lu _ m w ; N TO BE ABANDONED, Y Z o o ? z CO (APPROX) c.I a � �, I W� « U) � a LU 00 mO 00 N w N SEE DWG C-1 CO (D z EO CO + J4 0 o = i W W� LLI W W WLU � W WQ W~ W WD Cl)X X Xw'N O� X w X X X M X W co J w w w0 w w Ww wo — — — — — —_-- m� 375\two O — — — — — — — — — -- -- — — — EX 8" SD, _ LL iL TO BE ABANDONED -_ 370 < o - o - , (Ex.12-IN SD ABAN ONED N �N LO 0 YYYYYYYYYYYY iii 0 0 0 EP SD S=0.50% I 212± LF - 12" C 275± LF - 15" CPEP SD S=0.50% 365 34±LF-12"DI SD S=0.50% PIPE TRENCH, SEE DETAIL VC-7 I 367. 3 +/- i 360 T/P SS Raised Existing SS Raised Existing SS Raised Existing SS ith 2 - 45 degree Bends (to with 2 - 45 degree Bends with 2 - 45 degree Bends ( go over Storm Drain to go over Storm Drain ` to go over Storm Drain _ IE 369.46 12" OUT (N) 355 IE 66.25 15" OUT (N) 366.08 15" OUT (N) 355 IE 3 .50 12" IN (S) 366.20 12" IN (S) IE 367.56 12" OUT (N) 367.13 12" OUT (N) IE 371\04 12" IN (SW) 370.80 12" IN (SW) IE 369.29 12" IN (S) 368.68 12" IN (S) IE 368.38 12" IN (SE) L3 12" IN (SE) IE 367.56 12" IN (NE) 367.13 12" IN (NE) 345 AS-B U I LT NOTES OOLD SD DOWN SLOPE ABANDONED. As -built Elevations from Redline Drawing from Contractor's Surveyor. _ 1:3 U I L I PLS stamp not provided. 0 6 0 7 0 810 910 cONsuL7arvrs BHC Consultants, LLC 1601 Fifth Avenue, Suite 500 Seattle, Washington 98101 206.505.3400 206-505.3406 (fax) www.bhcconsultants.com SURVEYED: SCALE: KPG L• NAD VERTICAL: NAVD 1988 1 ASBUILT NOTES, REVISIONS, SOME DESIGN BT/DC 7/2017 DC DESIGNED: HORIZ: 1 "=20'-O" HORIzONTA1-3/19e1 e INFO REMOVED FOR CLARITY. P. CUNNINGHAM, P.E. VERT: 1 re =5' -0' DRAWN: P. SIMON ONE INCH DATUM CHECKED: AT FULL SCALE J. KRESHEL, P.E. IF NOT ONE INCH ROVED: SCALE ACCORDINGLY APPROVED: N0. REVISION BY DATE APPR A. QUYNN, P.E. OFFSET 29.40' LT #426 d, 1219 120 11+00 CITY OF AN RENTON Public Works Dept. NOTES: 1. CONTRACTOR SHALL POTHOLE AND VERIFY THE LOCATION, DEPTH, SIZE, MATERIAL AND CONFIGURATION OF THE EXISTING UTILITIES. VERIFICATION SHALL BE COMPLETED FAR ENOUGH IN ADVANCE OF THE CONSTRUCTION TO ADJUST PROPOSED STORM DRAIN SYSTEM TO ACCOMMODATE ACTUAL CONDITIONS. UNDER NO CIRCUMSTANCES WILL CITY PAY THE CONTRACTOR ADDITIONAL MONIES TO RELAY STORM DRAIN AND/OR REINSTALL STRUCTURES AS A RESULT OF THE CONTRACTOR'S FAILURE TO POTHOLE AND VERIFY EXISTING UTILITIES. 2. THE LOCATION OF EXISTING UTILITIES SHOWN ARE APPROXIMATE. NOT ALL UNDERGROUND UTILITY DEPTHS ARE KNOWN. THE CONTRACTOR SHALL TAKE PROPER PRECAUTIONS TO NOT DAMAGE ANY EXISTING UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGES CAUSED DUE TO FAILURE TO LOCATE AND PRESERVE ANY/ALL EXISTING UTILITIES. 3. SURVEY CONTROL NUMBERS F#], SEE DWG G-2. 4. THE MIN REQUIRED CLEARANCE OF CROSSINGS (ABOVE OR BELOW) BETWEEN THE NEW STORM DRAIN AND EX UTILITIES (WATER, SEWER, GAS, POWER, PHONE, OR CABLE; MAINS AND SERVICES) IS 12 INCHES FOR UTILITIES GREATER THAN OR EQUAL TO 6 INCHES IN DIAMETER AND 6 INCHES FOR UTILITIES LESS THAN 6 INCHES IN DIAMETER. WITH THE ENGINEER'S APPROVAL, EXCEPTIONS MAY BE ALLOWED PROVIDED THE USE OF ACCEPTABLE MATERIAL(S) IS USED FOR SEPARATING AND PROTECTING THE NEW STORM DRAIN AND EXISTING UTILITY. CROSSING CONDITIONS NOT LISTED SHALL BE APPROVED BY THE ENGINEER, SEE DETAIL 4/C-7. 5. LOCATIONS OF THE SIDE SEWERS SHOWN ARE APPROXIMATE AND MAY NOT REFLECT ACTUAL LOCATIONS. 6. SEE DRAWING C-1, EXISTING CONDITIONS AND DEMOLITION PLAN, FOR EXISTING STORM WATER INFRASTRUCTURE REMOVAL AND ABANDONMENT REQUIREMENTS. D=3 6 17 12 CONSTRUCTION NOTES: OREMOVE AND REPLACE EX CB. SEE CITY OF RENTON STD PLANS 200.00 AND 204.50. OCONTRACTOR SHALL POTHOLE AND FIELD VERIFY ELEVATIONS AT WATER CROSSING PRIOR TO CONSTRUCTION. OCONSTRUCTION CENTERLINE EQUALS PIPE CENTERLINE. SEE CONTROL DATA, DWG G-2 OPROTECT EXISTING TREE, HAND EXCAVATE OR TUNNEL TO INSTALL PIPE AS NECESSARY OR WHERE DIRECTED BY ENGINEER, FOR SPECIFIC REQUIREMENTS AND RESTRICTIONS SEE SPECIFICATIONS. 70 PROTECT EXISTING WATER MAIN DURING CONSTRUCTION. ( CONTRACTOR SHALL EXCAVATE, BACKFILL, AND RESTORE. CITY SHALL INSTALL CUT IN VALVE. COORDINATE WITH CITY PRIOR TO PERFORMING WORK. 1 - 6" DI GV, MJ x MJ 2 - 6" DI SPOOLS 2 - 6" TRANSITION COUPLINGS 1 - VALVE BOX CONTRACTOR TO REMOVE AND REPLACE EXISTING 6" CAST IRON WATER PIPE AS NECESSARY OVER TRENCH TO SAFELY INSTALL 24" HDPE PIPE AND PIPE ANCHOR. 10 OPEN CURB FACE FRAME AND VANED GRATE PER CITY OF RENTON STD PLAN 203.00 12 SOLID ROUND FRAME AND COVER PER CITY OF RENTON STD PLAN 204.50. 13 LOCATION AND DEPTH OF EXISTING SIDE SEWER UNKNOWN. SIDE SEWER SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONTRACTOR SHALL FIELD LOCATE EXISTING SIDE SEWER. IF LOCATION CONFLICTS WITH NEW STORM DRAIN AND/OR APPURTENANCES, RELOCATION OF THE SIDE SEWER MAY BE REQUIRED. IF REQUIRED, CONTRACTOR MUST NOTIFY SEWER PURVEYOR OF CONFLICT AND RELOCATE SIDE SEWER AS NECESSARY AND IN ACCORDANCE WITH THE CITY STANDARDS AND RELATED REQUIREMENTS. GCORE INTO EX SDMH AND MAKE CONNECTION WITH NEW 12" STORM PIPE. RECOMMENDED FOR APPROVAL BY Allen G. Quynn BY Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE MAPLEWOOD CREEK STORMWATER OUTFALL IMPROVEMENTS STORM DRAIN PLAN AND PROFILE ASBUILT STA 5+00 TO 9+32± DATE JULY 2015 FIELDBOOK: PAGE: C-3 SHEET: 6 OF: 10