Loading...
HomeMy WebLinkAboutWWP2703626.4LAIL H. wa pZ u no C D � n- P� W °z m z m m 0 D N:171994.29 E:1296467.28 EXISTING CB - RIM=19.78 IE N 12"CONC=15.58 IE W 16"CONC=15.38 6" ST --- -- - 6"� m m z PROPOSED WET WELL f ---i m �1 m � FM m z -- — � o � PROPOSED VALVE VAULT _ PROPOSED TELEMETRY ANTENNA \ N:171939.29 PPOPO-gPr) MAPI P TPPP w - EXISTING 48" SSMH RIM = 21.37 8"IEIN=7.05 8" IE OUT = 6.97 _ T ST ST - -- ST\— SW 9TH �� CONTRACTOR TO RESTORE ALL H DISTURBED STRIPING T(�CITY STANDARDS t i EXISTING 8" GRAVITY ; SEWER MAIN L,..� RIM=20.66 IE W 48"CONC=8.66f IE E 48"GO =8.6Gf 2'±F00T OF SILT AT BOTTOM ABL INE EXACT IE pw� ft 8" IE OUT = 6.78 EXISTING WMH N: 171884.908 E:1296582.225 w w; OVERALL PROPOSED SITE PLAN_ 1"=10' PETP. P' (w PETROLEUM Mk PROPOSED 8" C900 90 DEGREE BEND BELL x BELL WITH THRUST BLOCK 8 � s PROPOSED 8" C900 FORCE MAIN -� APPROX. 9 LF PROPOSED 8'xl8' VALVE VAULT 450 BEND, TYP. PROPOSED DROP IN EXISTING MANHOLE PROPOSED 8" C900 FORCE MAIN APPROX. 167 LF POINT DATA AND DESCRIPTIONS i POINT # NORTHING EASTING ELEVATION DESCRIPTION ! 1 171,957.64 1,296,503.85 21.39 CENTER OF WET WELL 2 171,962.14 1,296,494.89 21.18 NE CORNER OF VALVE VAULT 3 171,953.14 1,296,475.89 21.27 SW CORNER OF VALVE VAULT 4 171,968.25 1,296,519.10 21.45 NE CORNER OF GENERATOR PAD 5 171,956.25 1,296,514.10 21.45 SW CORNER OF GENERATOR PAD 6 171,987.99 1,296,526.68 PER PLAN NE CORNER OF ELECTRICAL BUILDING 7 171,979.32 1,296,516.01 PER PLAN SW CORNER OF ELECTRICAL BUILDING 8 171,975.34 1,296,478.07 PER PLAN 90 DEGREE BEND IN FORCE MAIN 9 171,969.21 1,296,476.31 21.03 NW CORNER OF CURB 10 171,969.21 1,296,512.33 MATCH EXISTING NE CORNER OF CURB 11 171,949.15 1,296,476.05 21.33 SW CORNER OF CURB 12 171,976.70 1,296,549.47 MATCH EXISTING UPPER NW CORNER OF PVMT RESTORATION 13 171,927.29 1,296,502.41 MATCH EXISTING WEST CORNER OF PVMT RESTORATION 14 171,915.29 1,296,502.36 MATCH EXISTING SW CORNER OF PVMT RESTORATION 15 171,915.09 1,296,547.10 MATCH EXISTING SE CORNER OF PVMT RESTORATION 16 171,976.70 1,296,558.62 MATCH EXISTING UPPER NE CORNER OF PVMT RESTORATION 17 171,976.70 1,296,565.92 MATCH EXISTING NW CORNER OF PVMT RESTORATION 18 171.971,70 1,296,610.97 MATCH EXISTING SE CORNER OF PVMT RESTORATION 19 171,976.70 1,296,623.49 MATCH EXISTING NW CORNER OF EAST SDWLK RESTOR. 20 171,971.70 1,296,630.01 MATCH EXISTING SE CORNER OF EAST SDWLK RESTOR. 21 - - SEE DETAIL END OF WET WELL PASSIVE VENT PROPOSED 8'X10' ELECTRICAL BUILDING. SEE DWG NO. S02, S03 AND SPECIFICATIONS FOR DETAILS. ELECTRICAL HANDHOLES, SEE DWG. NO. E03 FOR — DETAILS PROPOSED 10' INTERNAL DIAMETER WET WELL IEIN=5.4'SE FLOOR EL. — 6" PROPOSED CONCRETE �f PROPOSED SITE LIGHTS, CURB, MATCHED EXISTING SEE PLAN FOR DETAILS ANTENNA ON LIGHT POLE PROPOSED SITE PLAN 1"=5' S=362604 N0. 6 I I i i I I PROPOSED GENERATOR PAD W/ GENERATOR. SEE DWG NO. E08 FOR DETAILS WET WELL VENT kt' AL SIGNED: 01/17/13 SIGNED: 01 /17/13 \NT�� W Z W Oui Z Z uJ C) cc L Q O ~ co �... LL. uj aC a Z NVIIIIIIIIIII •i Z Q J C. W 0 W O C O w a ItiG.NEERS ''LAN N ERS SC-IENTISTS4 RI-12 ENGINEERING, INC. �ttp: `, /www.rh -4 -em ,-iaiibOX4^2.- '.8 1--.72C''.SO BELLINGHAM 3r-o-e-76,os3c- Ai SHOWN 0 1„ 2„ DRAWING IS NOT TO SCALE 21 IF BAR IS NOT 2" LONG / PLOT: 1 DWG N0. ENGINEER: DEB Cj02 PROPOSED 8" GATE VALVE, 607 REVIEWED: MM TYP. SEE ISOLATION DETAIL C05 DATE. Nov 11, 2014 �,NEET NO. CLIENT REN 04 REVISED PER CONSTRUCTION RECORDS MRJF MLM 09/16/14 JOB NO 112-023 F") REVISION BY REVIEW DATE FILENAME LIND-D-CIV02.DWG D n 0 o0 D0 m� �cn D �m c� �0 D m m u� ul m 0 D r wo N cz�- w r z® D m 0 O 3D� m 0o CD a� G