Loading...
HomeMy WebLinkAboutWWP2703626.7H. •A. 1 Z - c m C Mo �m a)- Nz IT z m Cn 0 D 306 CONCRETE SPREAD FOOTING, SO 0 SO THE QO CONCRETE sob ENTRANCE LANDING CMU OP RS EXISTING CURB - - FLOOR PLAN 01 Y" = 1'-0" 2 BROKEN FACE EXTERIOR - CMU WALL, TYP 402 SO LOUVER 1 i PRESSURE TREATED FRAMING BETWEEN CMU AND A/C UNIT, TYP j f VENTILATOR —' #5 @ 12" O.C. EW, 8'-( a-4" CENTEREDIN SLAB, TYP '-O" I 6„ J Y4" PJF, TYP " In CMU CORNER 40 RST,TYP So 5/ ANCHORS @ 32" O.C. FOR SILL PLATE ATTACHMENT 2" THICK EXTRUDED POLYSTRENE INSULATION. FULL PERIMETER, TOP SHALL BE AT 3" BELOW FINISH GRADE, TYP. 6" CRUSHED SURFACING BASE PROOF ROLL NATIVE STRUCTURAL FILL COMPACTED COURSE COMPACTED TO FIRM MATERIAL PRIOR TO SPREAD FOOTING AND UNYIELDING CONDITION. TYP STRUCTURAL FILL J TO 95% MAX DRY DENSITY PER BELOW ALL SLABS AND FOOTINGS. PLACEMENT, TYP MODIFIED PROCTOR. 306 SO SECTION Sal Y" = 1'-O" 2 TRUSS NOTES: PREFABRICATED CONNECTOR PLATE WOOD ROOF TRUSSES AND OTHER FRAMING SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH ANSI/TPI 1-1995 FOR THE SPANS AND CONDITIONS SHOWN ON THE DRAWINGS AND A MAXIMUM TRUSS DEFLECTION OF 1", j LOADING SHALL BE AS FOLLOWS: ROOF DEAD LOAD: TOTAL DEAD LOAD =12 PSF, INCLUDES: ROOFING: 1.5 PSF SHEATHING: 2.0 PSF TRUSSES: 2.0 PSF ASSUMED INSULATION: 0.5 PSF (1) LAYER OF I INCH PLYWOOD: 3.0 PSF MISCELLANEOUS MECHANICAL: 3.0 PSF. SNOW LOADS = 25 PSF NOTE: 1) SEE ELECTRICAL PLANS FOR UNDER/IN SLAB CONDUIT. 2) GROUT CMU CELLS WHERE PANELS ARE ATTACHED. SEE ELECTRICAL PLANS FOR LOCATIONS. ALUMINUM GUTTER, TYP ALL AROUND ROUTE DOWNSPOUT BACK TO BUILDING. PROVIDE CONCRETE SPLASHBLOCK AT BASE, TYP FULL DEPTH VENTED EAVE BLOCKING, TYP 1 f 2" THICK CDX OR BETTER APA RATED PLYWOOD WITH 8d NAILING @ 6" O.C. OVER WALLS AND AT PANEL EDGES, 12" O.C. FIELD 30 LB ROOFING FELT OVER PLYWOOD DECKING METAL ROOFING SYSTEM AND FLASHING TRUSSES @ 2'-0" O.C. STEP TRUSSES AS NECESSARY it I ! \ 4V:12H 01 i \ / ! 4 1V 2H 4V:12H a / \ - - 4V:12H--�- f CD SIMPSON A34 @ 24" O.C. BLOCKING TO TOP PLATE, TYP. SIMPSON L50 @ 24" O.C. TRUSS TO TOP PLATE. — TYP EA END TRUSS. ROOF PLAN v2 = 1'-0" LM 1 OVERHANG TYP 2x HIP RAFTER,TYP 2x HIP JACK @ 24" O.C. RIDGE VENT AT PEAK AND HIPS TO PROVIDE MIN 10 SQ. IN. OF NET FREE VENTILATED AREA PER LINEAR FT. 02 SO SIMPSON H4 @ 24" O.C. TRUSS TO TOP PLATE, TYP EA END TRUSS. DOOR AND FRAME SCHEDULE Door Frame No. Size Material Size Material Exit Device Required Width Height Width Height D01 F-O" 7'-2" HM 514" 7'-4" HM YES VENTILATOR SCHEDULE NO. FLOW FLOWRATE BACKDRAFT DAMPER MANUFACTURER MODEL ACCESSORIES EF-1 EXHAUST 410 SCFM YES ACME ENGINEERING FQ098 BACK GUARD LOUVER AND DAMPER SCHEDULE NO. FLOW FLOW RATE (SCFM) MANUFACTURER DAMPER. LOUVER DIMENSIONS ACCESSORIES* NOTES LA-1 INTAKE 410 POTTORFF CD42, EFD-445 16" X 16" MOUNTING SLEEVE, MOTORIZED ACTUATOR DAMPER TO OPEN ON EF-1 STARTUP LA-2 EXHAUST 410 POTTORFF CD42, EFD-445 16" X 16" MOUNTING SLEEVE GRAVITY DAMPER MOUNTING SLEEVES DEPTH SHOULD BE 18" MAX. REVISED TO CONFORM TO CONSTRUC N RECORDS RI-12 INEERING INC. DATE - 16727 ,/ p.GI9TE0 ONAT SIGNED: 01118113 SIGNED: 01/18/13 Uu Z Z Q W J a Za 0 Uj Z c 0 W o - cc0,111111111 � J CO) Q _ J LAftLL i � V W J a W � 71 E N G I N E E R S ANNERS C7:NTiSTS iRH2 ENGINEERING, INC. `-atp: //www.rh2.cam mailbox4h2com 1.80C.720.8052 SELLINGHAM 360,676.0836 -30-V HF-LL 425.951.s.a W %2722 29+� 210 EAST 'WENATCHEE so9.ss6.29oo '.00 Simon Street, S:_ - RICHLAND 5o9.Sk".5181 `14 Columbia Point give. °aILVERDALE Sea "021 'M Mhyre Rd, Suit, TACQMA 253.272 �21 Pacific Avenue Suite 104 SCALE: SHOWN 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG PLOT: 1 DWG NO ENGINEER: DEB SO1 REVIEWED: MM DATE: Nov 11, 2014 O7 CLIENT: REN Joe NO 112-023 1 Y20_ FILENAME LIND-D-S02.DWG D 0 M0 00 M C °0') D �m z� M° ul z m 0 D D Z GJ C 11 >Z 15 Z N �71 m Z z D T c 0 O 30 D AO c n A Cn p pf�- Ig-b-;:t bi