HomeMy WebLinkAboutWWP2703627.15ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT LIGHTING FIXTURES/DEVICES ABBREVIATIONS CIRCUIT BREAKER ;SERVICE ENTRANCE, SPDT - SINGLE POLE, DOUBLE THROW XXX/YY - CB SIZE & NO, OF POLES SWITCHGEAR, MOTOR CONTROL FLUORESCENT FIXTURE SPST - SINGLE POLE, SINGLE THROW i ET -ELECTRONIC TRIP CENTER, OR PANELBOARD DPST -DOUBLE POLE, SINGLE THROW j TM - THERMAL MAGNETIC BREAKER MCP - MOTOR CIRCUIT PROTECTOR SURFACE MOUNTED WALUCEILING MOUNTED FIXTURE WP - WEATHER-PROOF GFI - GROUND FAULT INTERRUPT SE - SERVICE ENTRANCE I PANELBOARD P -POWER GFI - GROUND FAULT INTERRUPTER C - CONTROL J - INSTRUMENTATION FUSE FLUSHED MOUNTED EMERGENCY LIGHT WITH SELF PC - POWER & CONTROL FUSED DISCONNECT SWITCH PANELBOARD ® CONTAINED BATTERY i CJ - CONTROL & INSTRUMENTATION PLUG-IN CONNECTION CKT. - CIRCUIT RTM RUN TIME METER NXX FIELD CONTROL STATION WITH NEMA SURFACE OR PENDANT MOUNTED FIXTURE C.O. - CONDUIT ONLY Fell REQUIREMENTS. I N.L. - NIGHT LIGHT EOC:] MOTOR OPERATION COUNTER N1 -NEMA 1 RECESSED FIXTURE AL. - ALUMINUM N3R - NEMA 3R CU. - COPPER SSRVS I N4 -NEMA 4 MD MOTION DETECTOR HOA -AUTO SWITCH I N4SS -NEMA 4 STAINLESS STEEL :HAND -OFF � ' SSRVS -SOLID STATE REDUCED VOLTAGE i N- NEMA 4 FIBERGLASS pC PHOTO CONTROL CELL ETM � RUN TIME METER OC OPERATION COUNTER - N6 -NEMA 6 STARTER N12 - NEMA 12 GASKETED SEAL MOTOR RLUN INDICATIONLIGHT SWITCH ovrLErsSEAL S Q STANDARD SWITCH, 120VAC, 20 AMP VARIABLE FREQUENCY DRIVE ,-� EQUIPMENT MOUNTING STAND SFTR ' SEAL FAIL TRIP RESET OTIL OVER TEMPERATURE INDICATION LIGHT MOTOR STARTER T ���� 3 I'-� 3WAY 3-WAY SWITCH, 120VAC, 20 AMP MOIL MOTOR OVERLOAD INDICATION LI HT MO 0 0 0G INDICATE TYPE BY A B MOTOR STARTER WI OPERATOR j HEATER, WATTAGE NOTED 3-POSITION SWITCH, 120VAC, 20 HOA ®HOA LETTER INSTRUMENT METER ICID DEVICES A - HAND -OFF -AUTO j ® EQUIPMENT CONNECTION AMP, LABEL SWITCH POSITION HAND -OFF -MOTION OR PHOTO V A - AMMETER VAR-VARMETER AH - AMPERE -HOUR VARH - VARHOUR METER S SINGLE -POLE S PILOT -LIGHTED B - OPERATIONAL COUNTER II PF - POWER FACTOR W - WATTMETER C - RUN TIME METER D - RUN LIGHT \�,\ �, '�� SINGLE PHASE MOTOR. DEE S2 P AM V - VOLTMETER WH - WATTHOUR METER HORSEPOWER AS NOTED DOUBLE -POLE K KEY -OPERATED VA - VOLT AMMETER E -FAIL LIGHT F - EMERGENCY STOP S THREE WAY S LOW VOLTAGE — RACEWAY LEGEND _ 5/Tff PI -AN LEGEND KIRK KEY INTERLOCK 100 THREE PHASE MOTOR. HORSEPOWER AS 3 4 FOUR WAY LV M MASTER P PROPOSED POWER M^ POWER TRANSFORMER Hp NOTED SINGLE PHASE MOTOR. S DIMMER D ❑ PUSHBUTTON TEL PROPOSED TELEPHONE �`✓� CONTROL POWER TRANSFORMER HORSEPOWER AS FIRE SYSTEM SYMBOLS CIE NOTED ELECTRICAL PLUG TELM PROPOSED INSTRUMENTATION <Ab HEAT DETECTOR TRANSFORMER , �., SMOKE DETECTOR Fa PROPOSED FIBER OPTICS DISCONNECT SWITCH � rVLDING 0P FADI XY PLAN L_fGEND CURRENT TRANSFORMER I FIRE ALARM DISPATCH STROBE ALARM EXPOSED RACEWAY � VOLTAGE TRANSFORMER � FUSED DISCONNECT SWITCH j DA FIRE ALARM AUDIBLENISUAL ALARM _ _ _ _ _ CONCEALED, UNDERGROUND. EMBEDDED., OR CONCRETE ENCASED RACEWAY F FIRE ALARM MANUAL PULL STATION CONTACTOR COMBINATION MOTOR STARTER AND DISCONNECT — HOME RUN TO PANELBOARD OR AS ; I ADDITIONAL SYMBOLS INDICATED SWITCH O SOUND SYSTEM SPEAKER CONDUIT RUN, BROKEN AND CONTINUED I CAPACITOR SOUND SYSTEM VOLUME CONTROL SAME SHEET OR AS NOTED ENGINE GENERATOR FLEXIBLE CONDUIT � DOORBELL GENERATOR CONNECTION CONDUIT RUN. HATCH MARKS INDICATE RECEPTACLE NUMBER OF CONDUCTORS VALVE SYMBOLS PILOT VALVE SOLENOID S SOLID NEUTRAL CALLOUT INDICATING CONDUIT SIZE, { I� I RECEPTACLES AND JUNCTION BOX SYMBOLS J � CEILING JUNCTION BOX N Y," GRC 2_#12 NUMBER AND SIZE OF WIRE. TB TERMINAL BLOCK WALL JUNCTION BOX I VALVE I CALLOUT INDICATING CONDUIT PER xxx SCHEDULE SURGE PROTECTION DEVICE ❑J FLOOR JUNCTION BOX CONDUIT BENT UP OR TOWARD i SPD SURGE PROTECTION DEVICE DUPLEX WALL RECEPTACLE, 120V CHECK VALVE I CONDUIT BENT DOWN OR AWAY ° ° I WP = WEATHERPROOF (ALTERNATIVE) G = GROUNDED IG = ISOLATED GROUND I ! CONTROL VALVE 7 CAPPED CONDUIT GROUNDING SYSTEM SYMBOLS �� GF = GROUND FAULT INTERRUPTER I _ ELECTRICAL & SIGNAL PLAN DEVICES _ GROUND DOUBLE DUPLEX ELECTRICAL SITE PLAN SYMBOLS S SV SOLENOID VALVE COIL ZS INTRUSION SWITCH METAL PIPE GROUND I UTILITY POLE AND GUY WIRE SINGLE RECEPTACLE, 120V -� � i MV MOTORIZED VALVE COIL MD MOTION DETECTOR ---�- POINT EXOTHERMIC I CONNECTIONSINGLE RECEPTACLE, 208V HH MANHOLE OR HANDHOLE i WELD. CADWELD OR APPROVED � MOTOR LT LEVEL TRANSDUCER EQUAL: ? ® DUPLEX FLOOR RECEPTACLE, 120V BURIED POWER VAULT OR MANHOLE , GROUND ROD SIZED PER N.E.C. USE EXOTHERMIC WELD 1 K� SPECIAL PURPOSE WALL �— i j T I TELEPHONE VAULT OR PEDESTAL FS FLOOD SWITCH HE HEATING ELEMENT CONNECTION AT THE GROUND ROD. RECEPTACLE, RATING AS NOTED LS LIMIT SWITCH PS PRESSURE SWITCH ! (� Q CLOCK j L FIBER OPTICS VAULT OR PEDESTAL PIGTAIL,. BARE COPPER, LENGTH AS LUMINAIRE PB PANIC BUTTON PE PRESSURE ELEMENT REQUIRED. 8' MINIMUM. i ❑TV TELEVISION CONNECTION POINT. MECHANICAL,` I PAD -MOUNT TRANSFORMER THERMOSTAT SWITCH FE FLOW ELEMENT I TELEPHONE COMPRESSION TYPE. ROAD EY ZS INTRUSION SWITCH - KEY AE ANALYSIS ELEMENT I TELEPHONE/DATA WITH CABLE LAL: SYMBOi i-ic v, INDICATOR LIGHT REbl Y INDICATOR LIGHT ' A - AMBER G - GREEN B - BLUE R - RED C - CLEAR W - WHITE LIMIT SWITCH LIMIT SWITCH, NORMALLY OPEN LIMIT SWITCH LIMIT SWITCH, NORMALLY CLOSED TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY OPEN, TIME TO CLOSE TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY CLOSED. TIME TO OPEN TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY OPEN, TIME TO OPEN TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY CLOSED. TIME TO CLOSE RELAY CONTACT, NC - RELAY CONTACT, INSTANTANEOUS CHANGE RELAY CONTACT, NO PRESSURE SWITCH PRESSURE SWITCH, NORMALLY OPEN PRESSURE SWITCH PRESSURE SWITCH, NORMALLY CLOSED XYZ RELAY TR - Timed relay 123 CR - Control relay FLOAT SWITCH FLOAT SWITCH PUSHBUTTON PUSHBUTTON FLOAT SWITCH, NORMALLY OPEN FLOAT SWITCH. NORMALLY CLOSED PUSHBUTTON, NORMALLY CLOSED PUSHBUTTON, NORMALLY OPEN THERMOSTAT THERMOSTAT SWITCH, NORMALLY OPEN THERMOSTAT THERMOSTAT SWITCH. NORMALLY CLOSED FLOWSWITCH FLOWSWITCH. NORMALLY OPEN FLOWSWITCH FLOWSWITCH, NORMALLY CLOSED 2 POLE SWITCH 3 POLE SWITCH GENERAL NOTES 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE WILL APPEAR IN THIS SET OF PLANS. I 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL EQUIPMENT SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS. CONTACT THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR REQUIREMENTS. 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER. S=3627 15 RECORD DRAWING j REVISED TO CONFORM TO CONSTRUCTI.ON RECORDS RH2 EebNEERING INC. DATE a � W z 3 F Lu uj or co a rn 0 w cn U N z� p o xgco W T in Z_ 3r c �e-o Z 8 j WN W N cli arI W J W W m W > � o C:,W I r O 'ol z SCALE: SHOWN 0. I„ Z. DRAWING IS FULL SCALE WHEN BAR MEASURES 2" � D � a � m n yl ' Z� Z - �o c MM L, Nz m z m O D 7 a _ > N � r 1 z D n a � M 0a > 3 cn `W Z E01 15 V21