HomeMy WebLinkAboutWWP2703627.15ONE -LINE DIAGRAM SYMBOLS
PANELBOARDS, SWITCHES, AND EQUIPMENT
LIGHTING FIXTURES/DEVICES
ABBREVIATIONS
CIRCUIT BREAKER
;SERVICE ENTRANCE,
SPDT - SINGLE POLE, DOUBLE THROW
XXX/YY - CB SIZE & NO, OF POLES
SWITCHGEAR, MOTOR CONTROL
FLUORESCENT FIXTURE
SPST - SINGLE POLE, SINGLE THROW
i
ET -ELECTRONIC TRIP
CENTER, OR PANELBOARD
DPST -DOUBLE POLE, SINGLE THROW j
TM - THERMAL MAGNETIC BREAKER
MCP - MOTOR CIRCUIT PROTECTOR
SURFACE MOUNTED
WALUCEILING MOUNTED FIXTURE
WP - WEATHER-PROOF
GFI - GROUND FAULT INTERRUPT
SE - SERVICE ENTRANCE
I PANELBOARD
P -POWER
GFI - GROUND FAULT INTERRUPTER
C - CONTROL
J - INSTRUMENTATION
FUSE
FLUSHED MOUNTED
EMERGENCY LIGHT WITH SELF
PC - POWER & CONTROL
FUSED DISCONNECT SWITCH
PANELBOARD
® CONTAINED BATTERY
i CJ - CONTROL & INSTRUMENTATION
PLUG-IN CONNECTION
CKT. - CIRCUIT
RTM
RUN TIME METER
NXX
FIELD CONTROL STATION WITH NEMA
SURFACE OR PENDANT MOUNTED
FIXTURE
C.O. - CONDUIT ONLY
Fell
REQUIREMENTS.
I
N.L. - NIGHT LIGHT
EOC:]
MOTOR OPERATION COUNTER
N1 -NEMA 1
RECESSED FIXTURE
AL. - ALUMINUM
N3R - NEMA 3R
CU. - COPPER
SSRVS I
N4 -NEMA 4
MD MOTION DETECTOR
HOA -AUTO SWITCH I
N4SS -NEMA 4 STAINLESS STEEL
:HAND -OFF
�
'
SSRVS -SOLID STATE
REDUCED VOLTAGE
i
N- NEMA 4 FIBERGLASS
pC PHOTO CONTROL CELL
ETM � RUN TIME METER
OC OPERATION COUNTER
-
N6 -NEMA 6
STARTER
N12 - NEMA 12 GASKETED
SEAL MOTOR RLUN INDICATIONLIGHT
SWITCH ovrLErsSEAL
S Q STANDARD SWITCH, 120VAC, 20 AMP
VARIABLE FREQUENCY DRIVE
,-�
EQUIPMENT MOUNTING STAND
SFTR ' SEAL FAIL TRIP RESET
OTIL OVER TEMPERATURE INDICATION LIGHT
MOTOR STARTER
T
����
3 I'-� 3WAY 3-WAY SWITCH, 120VAC, 20 AMP
MOIL MOTOR OVERLOAD INDICATION LI HT
MO 0 0 0G
INDICATE TYPE BY
A B
MOTOR STARTER WI OPERATOR
j
HEATER, WATTAGE NOTED
3-POSITION SWITCH, 120VAC, 20
HOA ®HOA
LETTER INSTRUMENT METER
ICID
DEVICES
A - HAND -OFF -AUTO
j ®
EQUIPMENT CONNECTION
AMP, LABEL SWITCH POSITION
HAND -OFF -MOTION OR PHOTO
V
A - AMMETER VAR-VARMETER
AH - AMPERE -HOUR VARH - VARHOUR METER
S SINGLE -POLE
S PILOT -LIGHTED
B - OPERATIONAL COUNTER
II
PF - POWER FACTOR W - WATTMETER
C - RUN TIME METER
D - RUN LIGHT
\�,\ �,
'��
SINGLE PHASE MOTOR.
DEE
S2
P
AM
V - VOLTMETER WH - WATTHOUR METER
HORSEPOWER AS NOTED
DOUBLE -POLE
K KEY -OPERATED
VA - VOLT AMMETER
E -FAIL LIGHT
F - EMERGENCY STOP
S THREE WAY
S LOW VOLTAGE
—
RACEWAY LEGEND
_
5/Tff PI -AN LEGEND
KIRK KEY INTERLOCK
100 THREE PHASE MOTOR.
HORSEPOWER AS
3
4 FOUR WAY
LV
M MASTER
P PROPOSED POWER
M^
POWER TRANSFORMER
Hp
NOTED
SINGLE PHASE MOTOR.
S DIMMER
D
❑ PUSHBUTTON
TEL PROPOSED TELEPHONE
�`✓�
CONTROL POWER TRANSFORMER
HORSEPOWER AS
FIRE SYSTEM SYMBOLS
CIE
NOTED
ELECTRICAL PLUG
TELM PROPOSED INSTRUMENTATION
<Ab HEAT DETECTOR
TRANSFORMER
,
�., SMOKE DETECTOR
Fa PROPOSED FIBER OPTICS
DISCONNECT SWITCH
�
rVLDING 0P FADI XY PLAN L_fGEND
CURRENT TRANSFORMER
I FIRE ALARM DISPATCH STROBE ALARM
EXPOSED RACEWAY
�
VOLTAGE TRANSFORMER
�
FUSED DISCONNECT SWITCH
j DA FIRE ALARM AUDIBLENISUAL ALARM
_ _ _ _ _ CONCEALED, UNDERGROUND. EMBEDDED.,
OR CONCRETE ENCASED RACEWAY
F FIRE ALARM MANUAL PULL STATION
CONTACTOR
COMBINATION MOTOR
STARTER AND DISCONNECT
— HOME RUN TO PANELBOARD OR AS
;
I ADDITIONAL SYMBOLS
INDICATED
SWITCH
O SOUND SYSTEM SPEAKER
CONDUIT RUN, BROKEN AND CONTINUED I
CAPACITOR
SOUND SYSTEM VOLUME CONTROL
SAME SHEET OR AS NOTED
ENGINE GENERATOR
FLEXIBLE CONDUIT �
DOORBELL
GENERATOR CONNECTION
CONDUIT RUN. HATCH MARKS INDICATE
RECEPTACLE
NUMBER OF CONDUCTORS
VALVE SYMBOLS
PILOT VALVE SOLENOID
S
SOLID NEUTRAL
CALLOUT INDICATING CONDUIT SIZE, {
I�
I RECEPTACLES AND JUNCTION BOX SYMBOLS
J
�
CEILING JUNCTION BOX
N
Y," GRC 2_#12 NUMBER AND SIZE OF WIRE.
TB
TERMINAL BLOCK
WALL JUNCTION BOX
I
VALVE
I
CALLOUT INDICATING CONDUIT PER
xxx SCHEDULE
SURGE PROTECTION DEVICE
❑J
FLOOR JUNCTION BOX
CONDUIT BENT UP OR TOWARD
i SPD
SURGE PROTECTION DEVICE
DUPLEX WALL RECEPTACLE, 120V
CHECK VALVE
I
CONDUIT BENT DOWN OR AWAY
° °
I
WP = WEATHERPROOF
(ALTERNATIVE)
G = GROUNDED
IG = ISOLATED GROUND
I ! CONTROL VALVE
7 CAPPED CONDUIT
GROUNDING SYSTEM SYMBOLS
��
GF = GROUND FAULT INTERRUPTER
I
_
ELECTRICAL & SIGNAL PLAN DEVICES
_
GROUND
DOUBLE DUPLEX
ELECTRICAL SITE PLAN SYMBOLS
S
SV SOLENOID VALVE COIL ZS INTRUSION SWITCH
METAL PIPE GROUND
I UTILITY POLE AND GUY WIRE
SINGLE RECEPTACLE, 120V
-� �
i
MV MOTORIZED VALVE COIL MD MOTION DETECTOR
---�-
POINT EXOTHERMIC I
CONNECTIONSINGLE
RECEPTACLE, 208V
HH MANHOLE OR HANDHOLE
i
WELD. CADWELD OR APPROVED
�
MOTOR LT LEVEL TRANSDUCER
EQUAL:
?
®
DUPLEX FLOOR RECEPTACLE, 120V
BURIED POWER VAULT OR MANHOLE
,
GROUND ROD SIZED PER N.E.C.
USE EXOTHERMIC WELD
1
K�
SPECIAL PURPOSE WALL
�— i
j T I TELEPHONE VAULT OR PEDESTAL
FS FLOOD SWITCH HE HEATING ELEMENT
CONNECTION AT THE GROUND ROD.
RECEPTACLE, RATING AS NOTED
LS LIMIT SWITCH PS PRESSURE SWITCH
!
(� Q
CLOCK
j L FIBER OPTICS VAULT OR PEDESTAL
PIGTAIL,. BARE COPPER, LENGTH AS
LUMINAIRE
PB PANIC BUTTON PE PRESSURE ELEMENT
REQUIRED. 8' MINIMUM. i
❑TV
TELEVISION
CONNECTION POINT. MECHANICAL,`
I PAD -MOUNT TRANSFORMER
THERMOSTAT SWITCH FE FLOW ELEMENT I
TELEPHONE
COMPRESSION TYPE.
ROAD
EY
ZS INTRUSION SWITCH - KEY AE ANALYSIS ELEMENT I
TELEPHONE/DATA WITH CABLE
LAL: SYMBOi i-ic v,
INDICATOR LIGHT REbl Y
INDICATOR LIGHT '
A - AMBER G - GREEN
B - BLUE R - RED
C - CLEAR W - WHITE
LIMIT SWITCH
LIMIT SWITCH, NORMALLY OPEN
LIMIT SWITCH
LIMIT SWITCH, NORMALLY CLOSED
TIME DELAY CONTACT
TIME DELAY CONTACT, NORMALLY
OPEN, TIME TO CLOSE
TIME DELAY CONTACT
TIME DELAY CONTACT, NORMALLY
CLOSED. TIME TO OPEN
TIME DELAY CONTACT
TIME DELAY CONTACT, NORMALLY
OPEN, TIME TO OPEN
TIME DELAY CONTACT
TIME DELAY CONTACT, NORMALLY
CLOSED. TIME TO CLOSE
RELAY CONTACT, NC
- RELAY CONTACT, INSTANTANEOUS
CHANGE
RELAY CONTACT, NO
PRESSURE SWITCH
PRESSURE SWITCH, NORMALLY OPEN
PRESSURE SWITCH
PRESSURE SWITCH,
NORMALLY CLOSED
XYZ RELAY
TR - Timed relay
123 CR - Control relay
FLOAT SWITCH
FLOAT SWITCH
PUSHBUTTON
PUSHBUTTON
FLOAT SWITCH, NORMALLY OPEN
FLOAT SWITCH.
NORMALLY CLOSED
PUSHBUTTON,
NORMALLY CLOSED
PUSHBUTTON, NORMALLY OPEN
THERMOSTAT THERMOSTAT SWITCH,
NORMALLY OPEN
THERMOSTAT THERMOSTAT SWITCH.
NORMALLY CLOSED
FLOWSWITCH
FLOWSWITCH. NORMALLY OPEN
FLOWSWITCH
FLOWSWITCH,
NORMALLY CLOSED
2 POLE SWITCH
3 POLE SWITCH
GENERAL NOTES
1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE
WILL APPEAR IN THIS SET OF PLANS. I
2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL
EQUIPMENT SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE
INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE
SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST
EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS. CONTACT
THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR REQUIREMENTS.
3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE
DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF
INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES
WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER.
S=3627 15
RECORD DRAWING
j REVISED TO CONFORM
TO CONSTRUCTI.ON RECORDS
RH2 EebNEERING INC. DATE
a �
W
z 3
F
Lu
uj or
co
a
rn
0
w
cn
U N
z�
p o
xgco
W T in
Z_ 3r c
�e-o
Z 8 j
WN W N
cli
arI
W
J
W
W
m
W
>
�
o
C:,W
I
r
O
'ol
z
SCALE: SHOWN
0. I„ Z.
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
� D
�
a � m
n
yl
' Z�
Z
- �o
c
MM
L,
Nz
m
z
m
O
D
7
a _
>
N
�
r
1
z
D
n
a
�
M
0a
>
3
cn
`W
Z
E01 15 V21