Sanitary Sewer Notes and Specifications
THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WASTEWATER UTILITY.
1. All work and work material shall be in conformance with the standards and specifications
of the City of Renton Planning/Building/Public Works Department and the latest edition
of the WSDOT/APWA Standards and Specifications, as approved and modified by the
City of Renton in the Renton Standard Plans & Specifications. A set of approved plans
shall be kept on site at all times during construction.
2. The hours of work in the street right of way shall be per City specifications on weekdays
unless otherwise approved in writing by the Planning/Building/Public Works Department
An approved traffic control plan must be obtained prior to beginning any work within
public right of way.
3. All locations of existing utilities shown are approximate and it shall be the contractor's
responsibility to verify the true and correct location so as to avoid damage or
disturbance.
4. A pre -construction conference and a 24 hour notice shall be required prior to starting
new construction. It shall be the contractor's responsibility to secure all necessary
permits prior to starting construction. (Inspection will be accomplished by a
representative of the City of Renton.) It shall be the contractor's responsibility to notify
the Public Works inspector 24 hours in advance of backfilling all construction.
5. Contractor is solely responsible for the means, methods and sequences of construction
and for the safety of workers and others on the construction site.
6. It shall be the responsibility of the contractor to obtain street use and any other related
permits prior to any construction. j
7. Plans approved by the City of Renton, Public Works Department shall take precedence j
over all other plans.
8. A copy of these approved plans must be on the job site whenever construction is in
progress.
9. The contractor shall provide the City of Renton with an as -built drawing of the sanitary
sewer system, which has been stamped and signed by a licensed professional engineer
or licensed professional surveyor.
10. Backfill shall be placed equally on both sides of the pipe in layers with a loose average
depth of 6 inches, maximum depth of 8 inches, thoroughly tamping each layer to 95
percent of maximum density. These compacted layers must extend for one pipe
diameter on each side of the pipe or to the side of the trench. Materials to complete the
fill over pipe shall be the same as described.
11. Open cut road crossings for utility trenches on existing traveled roadway shall be
backfilled with crushed rock and mechanically compacted unless otherwise approved by
12. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department. Reference benchmark and
elevations are noted on the plans.
13. All disturbed areas shall be seeded and mulched or otherwise stabilized to the
satisfaction of the Department for the prevention of on -site erosion after the completion
of construction.
14, All pipe and appurtenances shall be laid on a properly prepared foundation in
accordance with the standards and specifications of the City of Renton
Planning/BuildingjPublic Works Department and the latest edition of the WSDOT/APWA
Standards and Specifications, as approved and modified by the City of Renton in the
Renton Standard Plans & Specifications. This shall include necessary leveling of the
trench bottom or the top of the foundation material, as well as placement and
compaction of required bedding material, to uniform grade so that the entire length of
the pipe will be supported on a uniformly dense, unyielding base. Pipe bedding shall be
pea gravel 6 inches above and below the pipe.
15. Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D 3034,
SDR 35, or ductile iron class 50, unless otherwise approved by the Wastewater Utility,
16. In unimproved areas, manhole to extend minimum 6 inches and maximum 12 inches
above finished grade or must have minimum 2' diameter concrete ring poured at grade.
In paved area, cover must slope in all directions to match paving,
7' 1
F,
NOT TO SCALE
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2' MIN.)
SEE NOTE 6
MORTAR JOINT(S) (3/8" MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C-•443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX. PIPE SIZE - 'E'
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
'A'
`B'
`C°
I 'D'
'E'
48" MH
48"
6" MIN.
5"MIN
24" MIN.
21" I.D.
54" MH
54'
8" MIN.
5.5" MiN.
24" MIN.
24" I.D.
60" MH
60"
8" MIN.
6" MIN.
42" MIN.
30" I.D.
NOTES:
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PLAN 401.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, BRICKS AND MORTAR Qh, BRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED,
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR
APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL
11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE.
IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
PUBLIC WORKS STANDARD SANITARY MANHOLE tlifl. PLAN - 400.1
DEPARTMENT F
T SEPTEMBER 2011
PROPERTY LINE
z
b
!
FUTURE
6" BUILDING SEWER PIPE M
BUILDING SEWER
W
Z
POST PAINTED
TEE WITH 6" SIDE OUTLET
-'
2"x 4" STUD MARKING
6"X6"X6' WYE WHITE WITH THE WORD 'SEWER' STENCILED
SURFACE: CLEANQUT WITH CAST IRON RING & COVER IN 3" HIGH BLACK LETTERS AND /6 WIRE
THE STUD AND
g
(EAST JORDAN IRON WORKS WRAPPED AROUND
EXTENDED TO THE TOP OF THE STUD.
2975 OR APPROVED EQUAL
°-
SPECIFY "SEWER' ON LID,
SEE STD, PLAN 403,1 FOR
6" SIDE SEWER AND BUILDING SEWER
INSTALunoN)
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN
LINES ARE AS FOLLOWS:
A.
VITRIFIED CLAY MAIN - CUT IN A NEW TEE USING FLEXIBLE
COUPUNGS (FERNCO OR APPROVED EQUAL).
B.
CONCRETE MAIN - CORE -DRILLED NTH A ROMAC SADDLE (OR
APPROVED EQUAL).
C.
PVC MAIN - CORE: -DRILLED WITH A ROMAC SADDLE (OR APPROVED
EQUAL) OR CUT IN A NEW TEE USING RIGID COUPUNGS,
D.
DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR
APPROVED EQUAL)
E,
MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE
AT MANUFACTURED KNOCK -OUTS OR THE
STRUCTURE SHALL BE CORE --DRILLED.
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PiPE.
1: 3: 5 MIX kh
aG�,G G
CONCRETE -� °
BLOCKING
✓ PLO
G� 2X MIN SLOPE
HORIZONTAL
6" SIDE OUTLET TEE
SEWER
6" MIN, MAIN
SEWER MAIN
CONCRETE BLOCKING ANGLE
OF TEE AT MAIN OM _2,5
ELEVATION
TYPICAL SIDE SEWER ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE
A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
PUBLIC WORKS
c, rY ` STANDARD SIDE SEWER STD. PLAN - �•1
e( �. INSTALLATION -
\\ DEPARTMENT I (SEINER MAIN TO PROPERTY LINE) SEPTEMBER 2011
EST - _.-._
W (SEE NOTE 4) LIMITS OF PIPE ZONE
BEDDING MATERIAL FOR
SANITARY SEWER PIPE
(SEE NOTE 6)
O.D. OF PIPE
i
FOUNDATION LEVEL
BEDDING FOR SANITARY SEWER PIPE
NOTES
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY
SEWER SECTION OF THE STANDARD SPECIFICATIONS FOR TRENCH
WIDTH "W" AND TRENCHING OPTIONS. THE PIPE ZONE WILL BE THE
ACTUAL TRENCH WIDTH.
5. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING" IN THE SANITARY
SEWER SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT
ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER
SHALL NOT BE USED IN THE BACKFILL MATERIAL.
6. PIPE ZONE MATERIAL SHALL BE "GRAVEL BACKFILL FOR DRAINS" AS
SPECIFIED IN THE AGGREGATES SECTION OF THE STANDARD
SPECIFICATIONS.
7. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
� Y ° J? PUBLIC WORKS PIPE BEDDING SM. PLAN - 406
To DEPARTMENT FOR SANITARY S WERS MARCH 2O08
BOLTHOLES - 3 PLCS
EQUALLY SPACED 120'
APART ON 23 1/16' (586nn)
DIA B.C. (SEE DETAIL)
RENTi� N
SEWER
�MI� M IM
COVER & FRAME
PLAN VIEW
25' DIA.
(635mml 1'
3/4' �25nr7]
L19MMI
8 3/4' 2 1/2'
1222MI [64"n]
TYP
COVER SECTION VIEW
26 1/2' DIA
I673mml
25 1/4' DIA
L641mml 1 1/16'
t223
' TI)A C27mml
6'g4
5/8'DIA CL OPENC16mml94mm)
/16' DIA
L694mm)
34 1/8' DIA
COVER BOTTOM VIEW
BLT SOC. (ALLEN HEAD)
5/8'-11 X 1.5 SS
RUBBER WASHER
EON BOLTING DETAIL
1
1 1/16'
C6AM C27rn]
13MMI1/8'
nlCR3
GASKET GROOVE DETAIL
Lt3t) I MM] N xii:
FRAME 9FC I VIEW 1. ALL COVERS SHALL BE LOCKING UD PER EAST
JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL.
2. USE FRAME AND COVER FOR STORM (SPECIFY
"DRAIN" ON COVER), SANITARY (SPECIFY
"SEWER"), OR WATER (SPECIFY "WATER").
C-UAIR)-
PUB` '"" WORKSMANI°I CIE AND COVER
DF '.T"MEN'1'
STD. PLAN - 401