Loading...
HomeMy WebLinkAboutWWP2703684.213'r24' PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC, INC. 8CF SERIES NSBCF 1324-18 WITH 1.75' THICK DUCTILE IRON ❑ AMON❑ PLATE COVER EQUAL TO MID -STATES PLA"C5° INC. MSCBC-1324-R WITH REDER LID AND 2' DRILLED HO-E FOP. TCUCHREAD PIT LID (SEE DETAIL A -A) 9' MIN 12" MAX -FINISH GRADE r - aw _ - O 36" MIN CDVEP 22-1/2- OTY mm-E PIPING PPOG z ( IN UNIMPROVED RIGFT OF WAY INSTALL METER BCX AT F' PRCPERTY LINE WITH 12' LONG COPPER TAILPIECE, of 9D WALK Of 7.7 �TOUCHREAO WATER M -TER TO BE SUPPLIEC BY THE 12. z a CITY TYPE 'K- SOFT COPPER TU31NG NEW DUCTILE IRON I WATERMAIN % E s-RVICE LINE TO HOUSE IS Jr TO BE INSTALLED IN THE FUTURE INSTALL FORD C14-33 OR COMPRESSION COU'LING - LOOP DOWN TO CENTERLINE % OF WATER MAIN TO PP.OYDE SLACK IN OCWPE< : COP�RSETTER FOR 5/H'x3/47 METER_ FORD I� SERVICE LINE TO METER. ASH72-15M'-44-33tx OR McD•ONALD BRASS 21-215WC4?33. D� E MUELLER. 3,,4-3-2470­-2 WITH ANGLE HALL VALVE ON INLET AND % SINGLE CHEC- VALVE 3N OUTLET L CORPORATION STOP WTH BALL 'rALVE. FORD COPPERSETIER FOR 1" METER: FORD Vl#172-15W-44-44G, OR TAPERED THREAD ICC). QUICK JOINT McDONALD fTR.ASB- 21-415WMO44, OR MLELLER: 1-B-2470--2 (3/4- FBIDDO-3-0) OR AY MCDONALD 4701E BOTH INLET AND OUTLET LATH QUICK JOINT- PADLOCK WINGS ON (1' FBl "-4-Q) DR AY MCDONALD 470113 INLET ANGLE BALL VALVE AND SINGLE CiECK 'VALVE ON OUTLET. AL_ FITTINGS SHALL BE WITH OUI(Y JahT, NGTE: ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY_ EXPANSIO\ JOINTS MUSH BE INSTALLED ON BO-H SIDES OF METER BOX_ ti _ DRILL 2' ati HOLE FOR AMR (AU-OMATIG �I�F METER RE,.D) TOUCHREAD DEVICE f ` L 2-1/2' LAIN. FRCM NEAREST AND FRON- EDGE OF PIT LID TWICAL RIB 3/4- OR 1" GALVANZEC PLUG NOTE: THE CEN-ER OF TH- HOLE MUST BE AT LEAST 1' FROM UNDEP.NEATH RIBS JNLESS TFE RIB SPACING ALLCWS THE NUT TO 1GHTEN AGAINST THE O=EN SIDE CF MORE THAN ONE RIB- PUBLIC WORMS 4 AND 1" WATER SERVICE fD- PLAN - 30-1 + � + DEPARTMENT NOVEMBER 2CO9 6" BUILDING SEWER PIPE WITH 6" SIDE OUTLET 6" SIDE SEWER AND EIUILONIG SEWER 1:3:5 MIX CONCRETE 13LOCKING PROPERTY LINE z . b FUTURE BUILDING SEWER W Z 6"X5"X6" WYE �2"x 4" STUD MARKING POST PAINTED J SURFACE CLEANOUT NTH WHITE WITH THE WORD 'SEWER' STENCILED CAST IRON RING do COVER IN 3" HIGH BLACK LETTERS AND s6 WIRE w (SEE STD. ❑RW 403.1) '!RAPPED AROUND THE STUD AND EXTENDED TO THE TOP OF THE STUD. a ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN LINES ARE AS FOLLOWS: A. VITRIFIED CLAY MAIN - CUT IN .A NEW TEE USING FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). S. CONCRETE MAIN - CORE -DRILLED NTH A ROMAC SADDLE (OR APPROVED EQUAL). C. PVC MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) OR CUT IN A NEW TEE USING RIGID COUPLINGS. D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. 60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE. '� 6" SIDE OUTLET TEE t SEWER 6" MIN. MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 ELEVATION NOTE: UNLESS OTHERW15E SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS -OWER. � PING a �,NO X � G� 2% MIN SLOPE HORIZONTAL R MAIN TYPICAL SIDE SEWER ELEVATION r _ 4 PUBLIC WORKS STANDARD SIDE SO R SAD• PLAN - 4054 - DEPARTMENT (:EWER MAIN TO PROPERTY LINE) MARCH 2O10 WARNING: THE UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY. DEPTH UNKNOWN. CALL 1-800-424-5555. ���� r•; Ih rye ',I � ',,,.., . r.11rI rat �a j �X / ff A. HTd=. OR .aC� . a'S = / / / r fx 4 `e \" .F'JTFn I INF CR 6" IF1:• rT- nCF C_r,.55 '3 / I.. LANE _If.- c.S W N. ^" -)rnT1I ''^r Gf?Ir•IL' ��<4.�:•,b't,Ul ^•h> NLbrl':;'vL r = 6, 5' M I F, - 1 I• I' I' lit :J I xl tF.f3 ;r'dl MI N bl I I NI V, " P - I F.11 M1. R•.11 r•. i/ H'rl:, Jh' iA_.AV'd t' 'btt tILIt Lj /. Cl ^ F 'R- E' wFLSHED SLFF%,C F G TOP LO_P.SE, % rrvMP:ACT TO 33 M:OFIED P=CC-CR. `. � - CI?.!i I I: SU '1 ::: ;IPJ:[ ItA' C:R )L•ti :ill? fJAIIVL NrI=hIA_ It APhHU1'_: 1 *1 IIIAU .._ \ �� RY TFF FNGIFd===, C(Al'A, T ,h PT I _I u1 'r- -L O F1'_,POSE) MAGI LD 'HJC JN, I!IR CV-4) PI INS PI _ u c r rJ : H ,P 1,7 FI-E 7CNE EED 11,C MAT-- 1 ,•1J CONNECTON NLLLII IL ?LW: _A U,ll AS EEO-IP.SI E't T-1E 'ASCOT 'T•*IIDFRD 3T IL ,F- • F--I i 'e••,TIOA _-Q1= 1 8 SFFC rIC%+TI AF FOP -H- T FF 0- vFRwVFFJF�IT lt-E ,',_L_L. F:R NOTFS, S=F ST;4-,DAIPF P All 11'F:l PITBLtc ANORI.S+ TYPICAL TRANSVERSE PATCH M. PLAIT - 110 ` J�+ DEPARTMENT FOR FLEXIBLE PAVEMENT �-/ Pv1.AY 2I)Uy 8110MIN. RODF GRAIN STUB WITH CLEANOur, TYP LOT LTYP I� I i' HW PRIVATP ROOF OBAIN - PUBLIC STORM SYSTEM 1 GIJUEOTOR PIPE; PRIVATE STORM SEWER I I 8-0 Mal., SAS' MIN- BETWEEN GTR OF PIPE AVID FLOW. o.sx Mw. sLaPs, i 2 FT. MIN. COVER CLEAMUT, TYP.AT EVERY SIP, I I CURB• 81DEWALK OR 2ND 46• BEND. AND AT 889 FI. AX SPACING ON % RO.W. LINE SIRAW11T SECTIONS PRIVATr JOIN UTILITY EASEMENT. - ROOF DRAIN TO CONNECT 8'ITO CITY CN, MIN, Slat TYPE S MML WM'M NOTES: 1. PIPE MATERIALS ALLOWED: PVC, LCPE, TRIPLE WALL POLYETHYLENE t 8 DI. IF NECESSARY FOR STRENGTH) 2, THE ROOF A FOCrrING DRAIN SYSTEMS AFP PRIVATELY MAINTAM0 3. FLOW PATTERN SHOULD BE TO THE NEAREST CS IF GRADE ALLOWS, OR TO THE NEXT DOWNSTREAM CB. 4. ROOF DRAIN COLLECTORS MUST BE ANALYZED FOR CAPACITY. SIZED FOR 25-YF-AR PEAK FLOW. TYPICAL ROOF DRAIN �. PLAN _ PUBLIC WORKS COLLECTION STORM SYSTEM _ DEPARTMENT CIVIL PLANS MARCTT 2008 ®CONSULTING 34400 8th Avenue South ENGINEERS L L C 7 y'�E. .� Suite 205 I® I I Qr I r✓ Federal Way. WA 98003 FEDE1tAl wAr (293) 876-er u www.esmcivil.com EVERETf (425) 297-9900 / ✓ Civil Engineering Land Surveying I Land Planning 42334' Public Works Project Management Landscape Architecture C/SQ ESM JOB #258-040-012S�ONAL E 0 FIRST SUBMITTAL 1 SECOND SUBMITTAL 2 THIRD SUBMITTAL 3 FOURTH SUBMITTAL NO, NF kW O Farm iT, TYR CAP AND WHLRE :•-%mot 4 CJ_FANOUrr IS IN PAVEMENT; IMN MNG 6 .: COVER PER WOO NII47 OR EauwALENTEwr "`= + CATCH MAIN - AREA DRNN TEE r: tr r PROPERTY LINE U _ + L. _ �L - a W SETND PBMIANENTCAPORCONNBGTPm PRIVATE, JOINT USE LRILITY Ommlk r` �.:) d� - 4V WYE i TEE, CRUM, OR45° WYE AT aENa3 OLEAN-0UT WITH r1. PERMANENT CAP CLiA"UTOETA& N.LR. CATCH BASIN - AREA ORA^ �RCt'ION A.A ALIGN PIPETOM OR PLAICE ROOF ORM N HIGHER, 3 IA r-- ------{ -•AP ES -� ;;GL_-:; 02 _IYL 111 TO PORARY CAP ON END OF ROOF DRAIN STUB MARIEO BY riW STAKE PLACE CLEANOUT AT 3W MAX SPACE. AT Or BENDS, EACH 2ND W SEND. PIPE ENDS SRC'TION N NOTE: MIN. PIPE SIZE Ir O PPE MATERIALS ALLOWED: PVC, LINED CAE, TRIPLE WALL POLYETHYLENE, 01 (IF NEEDED FOR STRENGTH). PLBLt' I40RKS TYPICAL PRIVATE ROOF DRAIN STD. PLAN - 225.i0 * DFPARTMFNT COLLECTION SYSTEM CROSS SECTION MARC-T 2008 BACKFILL 24 Sm A� FILTER FABI AROUND TR 4"0 RIGID 6" MIN SF OF PIPE A -WASHED F 1.5"0 TO VARIES 1 A Ig a I PIPE ALLOWANCES PIP!��� SIMON FRAM AIG VANRa GNATS REI IP RCED OR 12' PLAIN CO CWTE <.- ALL METAL PIPE 15" SC --... - _r � 'P CP914P4 72" •:, r . SOLID WALL PVC /5` (STD. SPEC 9-05.12114 jr P RCF1LE WALL PVC 115" I8'OR t2• (STD. SPEC 9-e6.12I2H _ 1i * CQRRUriATEO POLYFTHYLEW - • STORM sEwER PIPE '•:� ONE w BAR HOOP FOR V HFI61-fT TWO 03 BAR HOOPS FOR 1T HFIGHT RECTANGULAR ARJESIMENT SEC7TON OFF q NOT!! y 1. As aac"bis aEematMes to vne rabar shown In the PRECAST BASE "II SECTION, thews (planed according to the SWndwd Speaifiat ions), or having D.12 hones foot - a.� alma mesh a minimum waa of square per shall be used with tie minimum requI ed rebar shown in the ALTERNATWE = 7 Z PRECAST BASE SECTION. WK mesh Shal not be placed Inthe / �• + knadmuts. 43 BAR EACH CORNER -"�. 4 � ' +� - -L`- _ 2. The WxKko A d6vneter Shell not be greater tian 20". K xx*ouio did hom a YmN thidunas of 2" rnir11Ir um to 2.5' rmudi, Lmn. Prov is a 1.6" " n 1• minir um gap between the knodnA wal and the outside of the pipe. Atler the pipe is insured, tithe gap with 1oiM mortar in accordance wA MR EACH S : '' q with Standad Specification 9-04.3 3. The maxlnlm deM hum to frNsheo grade to the lowest pipe Invert a1gN be 6. fIBBAR EACH WAY --"`y - PI�GYST tgAN tl■C7MN 4. The frame and grale, must be issUled Win the flange down. 5. The PItl4aBt Be" Secvon may have a IoundNM floor, antl i,e well ►Ray be s loped at a Rde of 1:24 or sleeper. 6. The opw*tg shall be measuied at the by Of the preomt base s4>GUon. 7. AN pIckW holes shag be grouted AM after the be* has boon placed. 8. AN grade rings and castings Shall be set in mortar in accordance with Standard 3peaficalioin .3. N3 BAR EACH CORNER 18` MIN. 03 DAR HOOP - Sm NOTE t ALTERNATIVE PRECAWT ■BARE 18Eti.'TON PUBLIC 'YORKS CATCH BASIN TYPE 'I SM. PLAN - 200.00 �r . -- DFP:1RTbTFNT �•_� IAARC-T 2008 L 4"0 SOLID PIPE r I.Ivry r Ll�r yr v-�r �✓ r .r � OR 6-0-FLEXIBLE PERFORATED PIPE HOUSE 368402 CHECKED FOR COMPLIANCE TO CITY STANDARDS PROFLE VON 1 SINGLE FAMILY ROOF DOWNSPOUT INFILTRATION TRENCH NOT TO SCALE ESM 2/04/ 1 3 SURVEYED: SCALE: ESM 3/28/13 DESIGNED: ESM 4/25/13us ESM 6/06/13 DRAWN: ER CHECKED: REVISION BY DATE APPR APPROVED VERTICAL: NAVD 1988 N HORIZONTAL: NAD 19B3/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY R CITY OF hl RENTON Planning/Building/Public Works Dept. N 26TH STREET SHORT PLAT UTILITIES PLANS DETAILS & NOTES 06/06/201 7ELDBOOK. PAGE DRAWING NO: UT-02 SHEET: 2 OF: z Fj �N `U r y So-