HomeMy WebLinkAboutWWP2703690.4NE 1/4 SECTION 14, TOWNSHIP 23 N, RANGE 5 E, W.M.
SADDLEBROOKDIV H FRONTAGE IMPROVEMENTS
SANITARY SEWER NOTES AND SPECIFICATIONS:
w
Lij
z j
c� -
D 0
O
0'
CL
Y
0
�'
0
ry
m
Ld
'Q
V /
7'
B,
I
NOT TO SCALE
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2" MIN.)
SEE NOTE 6
MORTAR JOINT(S) (3/8" MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C-443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL,
LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX. PIPE SIZE - 'E'
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
A'
'B'
'C'
'D'
'E'
48 MH
48
6" MIN.
5"MIN
24" MIN.
21" I.D.
54" MH
54"
8" MIN.
5.5" MIN.
1 24" MIN.
24" I.D.
60" MH
60
8" MIN.
6" MIN.
42" MIN.
30" I.D.
NOTES:
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PLAN 401.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED.
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR
APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL.
11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE.
IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING,
ti�Y O STD. PLAN - 400.1
+ n . PUBLIC WORKS DEPARTMENT STANDARD SANITARY MANHOLE
SEPTEMBER 2011
W (SEE NOTE 7) LIMITS OF PIPE ZONE
1 -0"
BEDDING MATERIAL FOR
SANITARY SEWER PIPE O.D. OF PIPE
(SEE NOTE 5)
FOUNDATION LEVEL
6"
BEDDING FOR SANITARY SEWER PIPE
NOTES:
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE
STANDARD SPECIFICATIONS.
5. PIPE ZONE MATERIAL SHALL BE "GRAVEL BACKFILL FOR DRAINS"
AS SPECIFIED IN THE AGGREGATES SECTION OF THE STANDARD
SPECIFICATIONS OR PEA GRAVEL.
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
U*v�
STD. PLAN - 405
PUBLIC WORKS PIPE BEDDING
DEPARTMENT FOR SANITARY SEWERS OCTOBER 2012
Call 2 Working Days Before You Dig
811
Utilities Underground Location Center
(ID,MT,ND,OR,WA)
A.
LN
R Cs~
L 0'
SEAL WITH AR 4000 OR
APPROVED EQUAL AND DRY
SAND AFTER PATCHING
PATCHED AREA
PLAN
N TS
2" ASPHALT CLASS "B"
OR AS APPROVED BY
THE ENGINEER.
'CONCRETE
SECTION A -A
NOTES:
REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE
WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS TWO FEET.
ADJUST CASTING FRAME TO PAVEMENT SURFACE USING RISER RINGS OR
CONCRETE BLOCKS PER STD. PLAN 400.1.
REPLACE ALL BUT TOP 2" OF EXCAVATED MATERIAL WITH
CLASS 3000 CONCRETE (3/4). FINISH PAVEMENT SURFACE
WITH 2" OF ASPHALT CLASS "B" OR AS APPROVED BY
THE ENGINEER.
Y
oti2 O.n TYPICAL UTILITY COVER STD. PLAN - 400.4
�.►� i PUBLIC WORKS ADJUSTMENT FOR
�NTo� DEPARTMENT PAVEMENT OR OVERLAY DECEMBER 2010
6" BUILDING SEWER PIPE
WITH 6" SIDE OUTLET
6" SIDE SEWER AND BUILDING SEWER
1:3:5 MIX
CONCRETE
BLOCKING
�ROPERTY LINE
Z
3'-0"
FUTURE
BUILDING SEWER
w \
Z `2"x 4" STUD MARKING POST PAINTED
6"XCXW' WYE WHITE WITH THE WORD "SEWER" STENCILED
SURFACE CLEANOUT WITH IN 3" HIGH BLACK LETTERS AND #6 WIRE
M CAST IRON RING & COVER
nw (EAST JORDAN IRON WORKS WRAPPED AROUND THE STUD AND
0 EXTENDED TO THE TOP OF THE STUD.
a 2975 OR APPROVED EQUAL,
SPECIFY "SEWER" ON LID,
SEE STD. PLAN 403.1 FOR
INSTALLATION)
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN
LINES ARE AS FOLLOWS:
A. VITRIFIED CLAY MAIN - CUT IN A NEW TEE USING FLEXIBLE
COUPLINGS (FERNCO OR APPROVED EQUAL).
B. CONCRETE MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR
APPROVED EQUAL).
C. PVC MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED
EQUAL) OR CUT IN A NEW TEE USING RIGID COUPLINGS.
D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR
APPROVED EQUAL)
E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE
AT MANUFACTURED KNOCK -OUTS OR THE
STRUCTURE SHALL BE CORE -DRILLED.
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PIPE.
6" SIDE OUTLET TEE
SEWER
6" MIN. MAIN SE
CONCRETE BLOCKING ANGLE
OF TEE AT MAIN OVER 25
ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE
A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
N00�
25 GR��E
GOB 2% MIN SLOPE
HORIZONTAL
R MAIN
TYPICAL SIDE SEWER ELEVATION
Y
STANDARD SIDE SEWER STD. PLAN - 406.1
® PUBLIC WORKS
INSTALLATION
DEPARTMENT
(SEWER MAIN TO PROPERTY LINE) SEPTEMBER 2011
D.R. STRONG
CONSUL TING ENGINEERS
ENGINEERS PLANNERS SURVEYORS
10604 NE 381h PL, #232 KIRKLAND, WA 98033
0425.827.3063 F 425.827.2423
N0.
REVISION
BDLTHDLES - 3 PLCS
EQUALLY SPACED 120'
APART ON 23 1/16' (586mm)
DIA B.C, (SEE DETAIL)
RENTON
SEWER
xna� ix usn
COVER & FRAME
PLAN VIEW
25' DIA.
C635mm] 1'
3/4' I
25mm]
C19mm]
8 3/4" L 2 1/2'
[222mm] 164mm]
TYP
COVER SECTION VIEW
26 1/2' DIA
C673mm]
25 1/4' DIA
1641mK] 1 1/16"
1/4' (6mm) DIA C27mm]
NEOPRENE GASKET
1 I� 6
C152 mm]
23 3/B' DIA CL ❑PEN
[16mm] C594mm]
27 5/16' DIA
C694mm]
34 1/8' DIA
COVER BOTTOM VIEW
(3) BLT SOC, (ALLEN HEAD)
5/8'-11 X 1,5 SS
RUBBER WASHER
EON BOLTING DETAIL
1/4' 1 1/16'
C6mm] r [27mm]
C3mm]
CR3mm]
GASKET GROOVE DETAIL
C867mm] NOTES:
FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST
JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL.
2. USE FRAME AND COVER FOR STORM (SPECIFY
"DRAIN" ON COVER), SANITARY (SPECIFY
"SEWER"), OR WATER (SPECIFY "WATER").
1`tY O
�',► '{ PUBLIC WORKS STD. PLAN - 401
+ '°•� DEPARTMENT MANHOLE FRAME AND COVER
"CFO DECEMBER 2008
RECESSED
LIFT POCKET
o
o/
SCREW 1 Ya' LONG
(BRONZE OR S.S.)
Y2" x 2" RAISED PADS
12 A"
14"
2�7
Ys
1 A„
2"
11
12 Y4„
III-_--
14"
CAST IRON
RING AND COVER
2 A�
� f .
6" CONCRETE
CLASS 3000
45' (1/8) BEND
2'-0'
J
SAND OR
EXPANDABLE
FOAM
WATER TIGHT
PLUG
8" 4�
P
�P
4
J�
O
FPS PIPE MATERIAL AS SPECIFIED
G� BY THE ENGINEER
45' (1/8) BEND
NOTES:
1. 8" AND 6" CLEANOUTS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC.
No. 3698 OR EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY.
2. IN UNIMPROVED AREAS, POUR A 1'-0" THICK, 2'-0" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER.
Y -
PUBLIC WORKS 8 OR 6 INCH CLEAN -OUT STD. PLAN 403.1
DEPARTMENT FOR SANITARY SEWER MAINS SEPTEMBER 2011
SURVEYED:
DESIGNED:
lW4J
DRAWN: VV11 pp
CHECKED'
MAJ
BY DATE APPR APPROVED:
lW4J
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE
LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED
BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS A SET OF APPROVED
PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON
WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS
DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY
WORK WITHIN PUBLIC RIGHT OF WAY.
J. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE
CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID
DAMAGE OR DISTURBANCE.
4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR N077CE SHALL BE REQUIRED PRIOR TO
STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL
NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A
REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO
NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION.
5. CONTRACTOR /S SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER
RELATED PERMITS PR/OR TO ANY CONSTRUCTION.
7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS.
8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS /N
PROGRESS.
9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE
SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL
ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
10. BACKF/LL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE
AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO
95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER
ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL
OVER PIPE SHALL BE THE SAME AS DESCRIBED.
11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXIS77NG TRAVELED ROADWAY SHALL BE
BACKF/LLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY
THE CITY OF RENTON.
12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VER77CAL DATUM 1988 METERS, AND
FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 198JI1991 METERS UNLESS OTHERWISE
APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND
ELEVATIONS ARE NOTED ON THE PLANS.
13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE
SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE
COMPLETION OF CONSTRUCTION.
14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN
ACCORDANCE WITH 77-IE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON
PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST ED177ON OF THE WSDOT/APWA
STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON /N THE
RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE
TRENCH BOTTOM OR THE TOP OF THE FOUNDAT70N MATERIAL, AS WELL AS PLACEMENT AND
COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE EN77RE LENGTH OF
THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE
PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE.
15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034,
SDR 35, OR DUCT/LE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY.
16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES
ABOVE FINISHED GRADE OR MUST HAVE MIN/MUM 2' DIAMETER CONCRETE RING POURED AT GRADE.
IN PAVED AREA, COVER MUST SLOPE /N ALL DIRECTIONS TO MATCH PAINING.
S 369002
t"OR
CITY OF
RENTON
Planning/Building/Public Works Dept.
RECOMMENDED FOR APPOVAL
BY: Date:
BY: Date:
BY: Date:
BY: Date:
SADDLEBROOK DIV. II
FRONTAGE IMPROVEMENTS
13422 156TH AVE SE
SEWER NOTES AND DETAILS
A -
DATE:
06.26.13
FIELDBOOK:
PAGE:
DRAWING NO:
SS2
SHEET: 9 OF: 9
NINININIAk
� d
Do
zo
0
m C
0