HomeMy WebLinkAboutWWP2703690.4NE 1/4 SECTION 14, TOWNSHIP 23 N, RANGE 5 E, W.M. SADDLEBROOKDIV H FRONTAGE IMPROVEMENTS SANITARY SEWER NOTES AND SPECIFICATIONS: w Lij z j c� - D 0 O 0' CL Y 0 �' 0 ry m Ld 'Q V / 7' B, I NOT TO SCALE MANHOLE FRAME AND COVER SEE STD. PLAN 401 ADJUSTMENT RINGS (2" MIN.) SEE NOTE 6 MORTAR JOINT(S) (3/8" MIN.) SEE NOTE 5 CONE (ECCENTRIC) RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL, LADDER -POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX. PIPE SIZE - 'E' CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. A' 'B' 'C' 'D' 'E' 48 MH 48 6" MIN. 5"MIN 24" MIN. 21" I.D. 54" MH 54" 8" MIN. 5.5" MIN. 1 24" MIN. 24" I.D. 60" MH 60 8" MIN. 6" MIN. 42" MIN. 30" I.D. NOTES: 1. STEPS TO BE POLYPROPYLENE SAFETY STEPS. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING SHALL BE PER STD. PLAN 401. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. 6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED. 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. 9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE. 10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. 11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING, ti�Y O STD. PLAN - 400.1 + n . PUBLIC WORKS DEPARTMENT STANDARD SANITARY MANHOLE SEPTEMBER 2011 W (SEE NOTE 7) LIMITS OF PIPE ZONE 1 -0" BEDDING MATERIAL FOR SANITARY SEWER PIPE O.D. OF PIPE (SEE NOTE 5) FOUNDATION LEVEL 6" BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE "GRAVEL BACKFILL FOR DRAINS" AS SPECIFIED IN THE AGGREGATES SECTION OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL. 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. U*v� STD. PLAN - 405 PUBLIC WORKS PIPE BEDDING DEPARTMENT FOR SANITARY SEWERS OCTOBER 2012 Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) A. LN R Cs~ L 0' SEAL WITH AR 4000 OR APPROVED EQUAL AND DRY SAND AFTER PATCHING PATCHED AREA PLAN N TS 2" ASPHALT CLASS "B" OR AS APPROVED BY THE ENGINEER. 'CONCRETE SECTION A -A NOTES: REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS TWO FEET. ADJUST CASTING FRAME TO PAVEMENT SURFACE USING RISER RINGS OR CONCRETE BLOCKS PER STD. PLAN 400.1. REPLACE ALL BUT TOP 2" OF EXCAVATED MATERIAL WITH CLASS 3000 CONCRETE (3/4). FINISH PAVEMENT SURFACE WITH 2" OF ASPHALT CLASS "B" OR AS APPROVED BY THE ENGINEER. Y oti2 O.n TYPICAL UTILITY COVER STD. PLAN - 400.4 �.►� i PUBLIC WORKS ADJUSTMENT FOR �NTo� DEPARTMENT PAVEMENT OR OVERLAY DECEMBER 2010 6" BUILDING SEWER PIPE WITH 6" SIDE OUTLET 6" SIDE SEWER AND BUILDING SEWER 1:3:5 MIX CONCRETE BLOCKING �ROPERTY LINE Z 3'-0" FUTURE BUILDING SEWER w \ Z `2"x 4" STUD MARKING POST PAINTED 6"XCXW' WYE WHITE WITH THE WORD "SEWER" STENCILED SURFACE CLEANOUT WITH IN 3" HIGH BLACK LETTERS AND #6 WIRE M CAST IRON RING & COVER nw (EAST JORDAN IRON WORKS WRAPPED AROUND THE STUD AND 0 EXTENDED TO THE TOP OF THE STUD. a 2975 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID, SEE STD. PLAN 403.1 FOR INSTALLATION) ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN LINES ARE AS FOLLOWS: A. VITRIFIED CLAY MAIN - CUT IN A NEW TEE USING FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL). C. PVC MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) OR CUT IN A NEW TEE USING RIGID COUPLINGS. D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. 60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE. 6" SIDE OUTLET TEE SEWER 6" MIN. MAIN SE CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. N00� 25 GR��E GOB 2% MIN SLOPE HORIZONTAL R MAIN TYPICAL SIDE SEWER ELEVATION Y STANDARD SIDE SEWER STD. PLAN - 406.1 ® PUBLIC WORKS INSTALLATION DEPARTMENT (SEWER MAIN TO PROPERTY LINE) SEPTEMBER 2011 D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 10604 NE 381h PL, #232 KIRKLAND, WA 98033 0425.827.3063 F 425.827.2423 N0. REVISION BDLTHDLES - 3 PLCS EQUALLY SPACED 120' APART ON 23 1/16' (586mm) DIA B.C, (SEE DETAIL) RENTON SEWER xna� ix usn COVER & FRAME PLAN VIEW 25' DIA. C635mm] 1' 3/4' I 25mm] C19mm] 8 3/4" L 2 1/2' [222mm] 164mm] TYP COVER SECTION VIEW 26 1/2' DIA C673mm] 25 1/4' DIA 1641mK] 1 1/16" 1/4' (6mm) DIA C27mm] NEOPRENE GASKET 1 I� 6 C152 mm] 23 3/B' DIA CL ❑PEN [16mm] C594mm] 27 5/16' DIA C694mm] 34 1/8' DIA COVER BOTTOM VIEW (3) BLT SOC, (ALLEN HEAD) 5/8'-11 X 1,5 SS RUBBER WASHER EON BOLTING DETAIL 1/4' 1 1/16' C6mm] r [27mm] C3mm] CR3mm] GASKET GROOVE DETAIL C867mm] NOTES: FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). 1`tY O �',► '{ PUBLIC WORKS STD. PLAN - 401 + '°•� DEPARTMENT MANHOLE FRAME AND COVER "CFO DECEMBER 2008 RECESSED LIFT POCKET o o/ SCREW 1 Ya' LONG (BRONZE OR S.S.) Y2" x 2" RAISED PADS 12 A" 14" 2�7 Ys 1 A„ 2" 11 12 Y4„ III-_-- 14" CAST IRON RING AND COVER 2 A� � f . 6" CONCRETE CLASS 3000 45' (1/8) BEND 2'-0' J SAND OR EXPANDABLE FOAM WATER TIGHT PLUG 8" 4� P �P 4 J� O FPS PIPE MATERIAL AS SPECIFIED G� BY THE ENGINEER 45' (1/8) BEND NOTES: 1. 8" AND 6" CLEANOUTS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC. No. 3698 OR EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. 2. IN UNIMPROVED AREAS, POUR A 1'-0" THICK, 2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER. Y - PUBLIC WORKS 8 OR 6 INCH CLEAN -OUT STD. PLAN 403.1 DEPARTMENT FOR SANITARY SEWER MAINS SEPTEMBER 2011 SURVEYED: DESIGNED: lW4J DRAWN: VV11 pp CHECKED' MAJ BY DATE APPR APPROVED: lW4J SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY. J. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR N077CE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR /S SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PR/OR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS /N PROGRESS. 9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 10. BACKF/LL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXIS77NG TRAVELED ROADWAY SHALL BE BACKF/LLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. 12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VER77CAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 198JI1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH 77-IE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST ED177ON OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON /N THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDAT70N MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE EN77RE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCT/LE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MIN/MUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE /N ALL DIRECTIONS TO MATCH PAINING. S 369002 t"OR CITY OF RENTON Planning/Building/Public Works Dept. RECOMMENDED FOR APPOVAL BY: Date: BY: Date: BY: Date: BY: Date: SADDLEBROOK DIV. II FRONTAGE IMPROVEMENTS 13422 156TH AVE SE SEWER NOTES AND DETAILS A - DATE: 06.26.13 FIELDBOOK: PAGE: DRAWING NO: SS2 SHEET: 9 OF: 9 NINININIAk � d Do zo 0 m C 0