Loading...
HomeMy WebLinkAboutWWP2703712.11N T t" �M ) O N Q z U_ EXTEND CHANNEL TO TOP OF 24" SEWER, TYP CONTRACTOR TO FIELD VERIFY SKEWED ANGLES AND INVERT ELEVATIONS 0 PRIOR TO FABRICATION OF BASE LINER, TYP EX 24" VCP SS, FIELD t VERIFY PIPE OD .38PRIOR TO ORDERING± COUPLING FLEXIBLE TRANSITION COUPLING, FERNCO OR EQUAL 24" SS PVC 4 LF 15" PVC SPOOL 15" PVC SS INSERTED INTO 15" VCP SS APPROXIMATELY 18" NOTES: 84" ID MH PER WSDOT STD PLAN B-15.60-01 MANHOLE BASE LINER PER SPECIAL PROVISIONS SECTION 7-05.3(6) STA 1 +00 o N 181167.65 o E 1303802.05 [' 24" SS 1 31.43 PVC IE 31.4± a \a SEE NOTE 3 -- - �— 1101, OFFSET a 18" _ MIN EX 15" CONIC SS, ` LEDERIFY PRIOR �ro ERINGNG FLEXIBLE Tr') A NSITIE)N i� EX 15" VCP SS o. R CONSTRUCT C/L EQUALS PIPE C/L BELL AND GASKET TO ACCEPT PVC PIPE BY BASE LINER MFR, TYP M SEE NOTE 2, TYP HSUCH THAT 15" SS QUADRANT OF MH CONTRACTOR TO FIELD VERIFY ENTRY ANGLE PRIOR TO FABRICATION OF BASE LINER 15" 22.5° 'PVC )I EX 36 STEEL CASING FOR WATER MAIN ABOVE 1 1. MANHOLE ACCESSORIES, COATING AND GENERAL INSTALLATION PER RENTON STD PLAN 400.1, EXCEPT MODIFIED AS SHOWN. 2. PLACE MH ON 12" CSBC EXTENDING V-0" BEYOND MH BASE, COMPACT TO 95% MDD PER ASTM D1557. 3. MH FRAME AND COVER SHALL BE INSTALLED OUTSIDE OF BNSF ROW AS SHOWN ON DWG C-1. FIELD VERIFY PRIOR TO INSTALLATION. 1968 NTS C-1 I BHC Consultants, LLC 1601 Fifth Avenue, Suite 500 Seattle, Washington 98101 �+ k'' ' 206.505.3400 C O 1 �1 U L I A 1T S 206.505.3406 (fax) Si EAT T L E TA C O M A www.bhcconsultants.com ORIGINAL ORIGINAL SEALED BY: SEALED BY: TYLER JAMES WHITEHOUSE JEFFREY S. KRESHEL 5/14/15 5/14/15 49545 32796 a AS -BUILT PHOTO LOOKING SOUTH AS -BUILT PHOTO LOOKING EAST REC041D DRAW',' ',' G These record drawings have been prepared based on construction records and as -built information provided by the contractor and others. BHC Consultants, LLC has not verified the accuracy and/or completeness of this information. Call 48 Hours Before You Dig 1-800-424-5555 UNDERGROUND SERVICE SURVEYED: SCALE: DATE: VERTICAL: NAVD 83/ CITY 0 CENTRAL RENTON SEWER INTERCEPTOR MAY 2015 KPG AS NOTED HORIZONTAL: NAD ,sas/,ee, DESIGNED: T. WHITEHOUSE, P.E. RELINE & UPSIZE PROJECT FIELDBOOK: DRAWN: R E N T O N PAGE: 0 RECORD DRAWING TJW 12/2016 RAD P. SIMON DRAWING N0: ISSUED FOR BID TJW 05/2015 JSK CHECKED: ONE INCH DATUM AT FULL SCALE r'ubiic works Dept. MISCELLANEOUS SEWER DETAILS C-2 J. KRESHEL, P.E. IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: OF: R. DORN, P.E. 5 6 D f"1 z Y� C� Z m= C O In_0 m- c C3 M2 m z m cn O D CD _G Z 0 C 9 W 11 r7l n CD z CD CD bz CD r CD Pr z 0CDz'C'n CAI C n tTj IMMMA o � D p In oO C: C ~ In Q i � C