HomeMy WebLinkAboutWWP2703732.3TBLOCK_COR
OTOP111108
CSIT111108
CNOT111108
CGRD111108
r)
CUSD111108
0
CUWS111108
U
keyrnap
W
OI LU M 111108
1
n
0 10 20
VERT. IN FEET
0 20 40
HORIZ. IN FEET
0
WI
520
510
490
N
M
480
i
470 v
Q
460
450
UTILITY PERMIT
NO. U 13002729
Copyright s. 2013 CPH Consultants, LLC, All Rights Resen
NE 1/4, NW 1/4, SEC.14, TWP.23N., RGE. 5E., W.M.
ELEVATION AT EXIST. GROUND
r ELEVATION AT FINISH GRADE
_I_ O h C� O C? O] h ct
In Qa x:r00
C N _ t+j t[j �?
- C6
32+40
32+80
33+20
34+00
CITY OF RENTON 1 CITY OF RENTON PERMIT SUBMITTAL
Approved by: Date:
Approved by: Date:
Approved by Date:
Approved b : Date: NO. REVISION
34+ 40
SEE C4.01
SEE C4.01
34+80
520
510
w
w 500
480
470
460
450
JBS
5/30/ 14
JBS
SURVEYED:
MITCH EVANS, PLS
Ste:
N/A
-
DESIGNED:
RYAN SCHAUBLE
DRAWN:
PETER EVANS
ONE INCH
CHECKED:
JAMIE B. SCHROEDER, PE
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
BY
DATE
AP P R
APPROVED:
APPROVED
4
FFE= 503.0
3
FFE=5D0.5
2
FFE= 49 7.5
VERTICAL NAVD 1988
HORIZONTAL: W 1983/1991
DATU M
CITY OF
RENTON
Planning/Building/Public Works Dept.
CONSTRUCTION NOTES
O6" SIDE SEWER CONNECTION W/CLEANOUT, 21-. MIN.
SLOPE PER COR STD. PLAN 406.1 AND 403.1
O48" SANITARY SEWER MANHOLE TYPE 1 W/ FRAME AND
COVER PER COR STD. PLAN 400.1 AND 401
30 SANITARY SEWER CLEANOUT PER COR STD. PLAN 403.1
J SAWCUT EXIST. PVMT.
CONNECT 6" SIDE SEWER TO MANHOLE PER CDR STD.
PLAN 406.1
GENERAL NOTES:
1. THE INVERT ELEVATON FOR INDIVIDUAL SANITARY SEWER
SERVICE CONNECTION STUBS SHALL BE SET A MIN. OF 5
FEET BELOW THE FINISHED FLOOR ELEVATION (FFE).
2. PIPE BEDDING FOR SANITARY SEWER MAIN SHALL BE PER
COR STD. PLAN 405.
3. ALL SANITARY SEWER MANHOLES ARE TYPE 1 PER COR
STD. PLAN 400.1 AND 401.
4. PAVEMENT RESTORATION SUBJECT TO FIELD MODIFICATION
BY THE CITY INSPECTOR,
5. PER CITY OF RENTON TRENCH RESTORATION DETAILS, IF
TRENCHING IS WITHIN 3 FEET OF AN ADJACENT LANE, THE
ENTIRE ADJACENT TRAVEL LANE AFFECTED WILL BE
REPAVED.
6. IF THERE IS LESS THAN 12 INCHES SEPARATION BETWEEN
UTILITY PIPES AT CROSSLINE, AN ETHAFORM PAD SHALL BE
PROVIDED.
RIF
S Chr
WA
w
37610 O w�
S ISTEggl,S�'
�SIOVAL G of {
CALL BEFORE
YOU DIG
1-800-424-5555
CONSULTANTS
Site Planning • Civil Engineering
Land Use Consulting - Project Management
733 7 th Avenue. Suite 100 1 Kirkland, WA 98033
Phone: ;4251285 2390 1 FAX: (425; 285-2389
www.Cphconsulrants.C9.'n
DAT-
MAPLEWOOD PARK EAST 5/30/14
ROADWAY GRADING, DRAINAGE AND SANITARY SEWER IMPROVEMENTS FIEL"OOK:
SANITARY SEWER PLAN AND PROFILE
PAGE:
DRAWING W.
C4.03
SHEET: OF:
27 36
a
b
r
boo
o
CD me
1
O N
a
�
tii
C