2" CLAS
*2" TO 6" C
OR C'
--- - - 6.5' MIN.
2" DEPTH OF
RIND OR SAWCUT AND REMOVE
F -- 6.5' MIN, -
1' 1' 2.5' 1' 1'
MIN IN MIN MIN MIN
2" CLASS `B'
CRUSHED ROCK, FLOWAE,�L- ���
OR AS REQUIRED BY ENGINEER
* FOR MINIMUM STANDARDS, SEE DWG# HR---05,
SP PAGE H032
OF CURB OR
OF PAVEMENT
;ENTER LINE OR
ANE LINE
S*
D SURFACING TOP COURSE
TYPICAL TRANSVERSE PATCH
FOR FLEXIBLE PAVEMENT
ADOPTED
CPPY OF RENTON
STANDARD PLANS
1ST DATE: 02/05
1 02/2005 tMOCRED NOTES
j07J2CO4 MOC:FlED NOTES DCV I G2
I_ DATE REyisION Y APPR n DWG. NAME: H032-1 SP PAGE: H032.1
MANHOLE FRAME AND COVER
PER STD. PLAN 401.
ADJUSTMENT RINGS (2" MIN.) ,
SEE NOTE 4
4 MIN, TO
MORTAR JOINT(S) (3/8' MIN.)----... 24•• 12" MAX. xQi
SEE NOTE 3 f �I
ADAPTOR
COLLAR a' i 16»
12' PIPE j
PRECAST VALVE RUBBER (MAX_) o
GASKET
CHAMBER CONE
R.C.P. OR zi
EQUAL ' m 5"
'
P D a
a '. �
C �. �
..
p p
lK
• aE;- MIN_
_
• 0 . n p . G .p P - .'sp p..
48 ' - --
L POURED -IN -PLACE BASE
NOTES:
1. CASTING SHALL BE PER STD. PLAN 401.
2. CONE SECTION TO BE OF REINFORCED PRECAST CONCRETE.
3. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
4. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A
COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL
BE STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND.
THE USE OF SHIMS IS PROHIBITED_
5. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER
MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
6. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443_
7. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE.
8. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL
BOOTS OR APPROVED EQUAL.
9, IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF
12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS
POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
PUBLIC WORKS
SANITARY MANHOLE
STD. PLAN - 400.9
DEPARTMENT
EXTRA SHALLOW
SEPTEMBER 2011.
BOLTHOLES - 3 PLCS
EQUALLY SPACED 120°
APART [IN 223 1/16' (566mm)
DIA B.C. (SEE DETAIL)
SEWER
COVER & FRAME..
PLAN VIEW
25' DIA,
C635mml 1'
_ 3/4' r fC` Smm7
Cl9mm7 �jt_ }
i It
8 3/4' 2 1/2'
C222mm1 164mmI
TYP
COVER SECTION VIEW
26 1/2' DIA
Cb73mm] j
25 1/4' DIA
C641mml 1 1/16'
J-1/4' (6mm) DIA 127mm3
i NEOPRENE GASKET
1 6'
� 1 ' '152mm2
5/8'
I 23 3t8' DIA CL CPEN
C16MM3 i594mml
27 5/16' DIA
C694mml
34 1/8' DIA
COVER BOTTOM VIEW
BLT SCC,(ALLEN HEAD)
5/8'-Il X L5 SS
RUBBER WASHER
EON BOLTING DETAIL
6mm7 I va/mm]
1/8,
C3mml
CR3^nm:
GASKET GROOVE DETAIL
C867mm1 NOTES:
FRAME SECTION VIEW 1, ALL COVERS SHALL BE LOCKING LID PER EAST
JORDAN IRON WORKS INC, No. 3717C1 OR EQUAL.
2, USE FRAME AND COVER FOR STORM (SPECIFY
"DRAIN" ON COVER), SANITARY (SPECIFY
"SEWER"), OR WATER (SPECIFY "WATER"),.
q
v` PUBLIC WORKSSTD.
FRAME AND COVER STD. PLAN - 401`'+ DEPARTMENTi DECEMBER 2008
7' I
NOT TO SCALE
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2" MIN.)
SEE NOTE 6
MORTAR JOINT(S) (3/8" MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C-443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL,
LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
!AAX. PIPE SIZE - 'E'
CONCRETE SHELT
PRECAST BASE SECTION
OR CAST IN SHELF.
A,
<B,
'C,
,D,
.E,
48" MH
481.
6" MIN.
5" MIN
2.4" MIN.
21" 1. D.
54" MH
54"
8" MIN.
5.5" MIN.
24" MIN,
24" I.D.
60" MH
60"
8" MIN.
1 6" MIN.
42" MIN.
30" I.D.
1407ES�
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PLAN 40'.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OFF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY, BRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED.
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC--AROSHIELD OR
APPROVED EQUAL; COLOR OF COALING SHALL BE WHITE.
8. RUBBER GASKETED JCINTS SHALL BE IN CONFORMANCE WTH ASTM C-443,
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL.
11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MIN?MUM OF 6" AND A MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE.
IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
.tiff O STD. PLAN 400.1
p ;+ PUBLIC TiORB9 STANDARD S�III`IIIITARY MANHOLE
�= DEPARTMENT
-fi0 I SEPTEMBER 2011
1 RECORD DRAWING (AS-BUILTS
NO. REVISION
09/29/'17
BY DATE
W (SEE NOTE 7)'
BEDDING MATERIAL FOR Y{
SANITARY SEWER PIPE
(SEE NOTE 5)
FOUNDATION LEVEL
%f f,
BEDDING FOR SANITARY SEWER PIPE
LIMITS OF PIPE ZONE
bLQIES
1. PROVIDE UNIFORM SUPPORT UNDER BARREL,
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL. TO 95X MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE: HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE
STANDARD SPECIFICATIONS.
5, PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)'
OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL.
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
STD. PLAN - 40S
PuBuc WORDS PIPE BEDDING PIp 1t-- �-
DEPARTMENT FOR SANITARY SEWERS
.�gigg r
I
PATCHED AREA
A A
t- COVER
I
I !{
i
I
i
SEAL 9A377 AR aiEW OR APPRCrVED PLAN I
EQUAL AND DRY SANG AFTER
PATCH NC N,TS
I
I
Q'.JTS UE D A.-- -- 2 -6' -•- DEPTH 3F CLASS `B
I ASPHALT TO BE 2" BELOW
BOTTOM OF UPPER
RING OR A
3, ApJUSNTE
MINIMUM OF B" WHICHEN eR
IS GREATER,
PDJUxTMENT RING
MINI.) ORORTAR
JGMT(S) (3/8" MiN(I"
SEE M,)
NOTE 3 AND "SPECIAL PROVISON BRICKS. SEE NOTE 4
NOTES
1. REMOVE PAVEME14T AND SASE MATERIALS FOR A DISTANCE v ALL JOINTS BETWEEN THE CONE, ADJUSTMENT RING'S,.
WHICH IS EQUAL. TO THE DtAMEFER OF THE FRAME PLUS FOUR BRICKS AND FRAME SHALL BE GROUTED
FEET. ADJUST CASTING FRAME TO PAVEMENT SURFACE
USWG RISER RINGS OR C ETE SLOCKS PER STO PLAN 4. ADJUSTMENT OF THE FRAME TO GRAf}E SHALL BE
ACCOMPILISHED WITH A CO MBINA710N OF ADA STWlENT
RINGS, BRICKS AND MORTAR ONLY, BRICKS SHALL SE
2. REPLACE EXCAVATED MATERIAL WITH A MWIMUM OF it OF STAGGERED T4 CREATE A RUNNING SOND OR 112 BOND, THE
CLASS W ASPHALT OR TO A DEPTH THAT IS 2' 13EL:OW THE tWE 4F CAMS 13 PROMOr ED,
BOTTOM OF THE UPPER ADJUSTMENT RING WHICHEVER IS
GREATER €3R AS APPROVED BY THE ENGINEER.
3i'D.mPLAT - 4t1ti.9�
PUBLIC
TYPICAL UTILITY COVER
Pid4El�IfK
DEPARTMENT`
A13JUSTMENT FOR
PAVEMENT OR 0VFJftLAY
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date
Date
DATE
RECOMMENDED
FOR APPROVAL
BY-
BY -
BY
SANITARY SEWER NOTES AND SPECIFICATIONS:
1. ALL WORK AND WORK MATERIALS SHALL BE IN CONFORMANCE WITH
THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON
PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION
OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF
APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING
CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER
CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN
WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN
APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING
ANY WORK WITHIN PUBLIC RIGHT OF WAY.
3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND
CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE.
4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL
BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR
TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A
REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR
24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION.
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND
SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND
OTHERS ON THE CONSTRUCTION SITE.
6, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN
STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY
CONSTRUCTION.
7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS
DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS.
8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE
WHENEVER CONSTRUCTION IS IN PROGRESS.
9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN
AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN
STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR
LICENSED PROFESSIONAL SURVEYOR.
10. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN
LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF
8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM
DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE
DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH.
MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS
DESCRIBED.
11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING
TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND
MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY.
12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL
DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH
AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY
THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK
AND ELEVATIONS ARE NOTED ON THE PLANS.
13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR
OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE
PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF
CONSTRUCTION.
14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY
PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC
WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA
STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY
OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS
SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP
OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION
OF THE REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE
ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE,
UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE
AND BELOW THE PIPE.
15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER
GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS
OTHERWISE APPROVED BY THE WASTEWATER UTILITY.
16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND
MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2'
DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER
MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
r
S=384608
DALEY-MORROW-POBLETE,
INC.
R s •
Q i�o
WASy/
AUBURN,
726
AUBURN WAY N.
WASHINGTON
�
PHONE: 253-333-2200,
98002
FAX: 253-333-2206
`3 I t l
ti
�o �, 28352 0 ��
IFS F0 l S T E`��`\\���`�
\
ENGINEERING - SURVEYING
LAND PLANNING
NA L `\``k
incorporated
STAMP NOT VALID UNLESS SIGNED do DATED
SURVEYED: SCALE: DATE:
N/A VERTICAL: NAVD 1988
AS SHOWN HORIZONTAL: NAD 1983/1991 �� CITY 0 F PRIL 28, 201
DESIGNED: �L
ASP RENTON MINDY'S PLACE°�°K
DRAWN:
PAGEi
ASP DRAWING NO:
ONE INCH DATUM
ASP CHECKED:DATUM
AT FULL SCALE Planning/Building/Public Works Dept. SEWER NOTES AND DETAILS 218000NSTAS
APPR ASP F NOT ONE INCH U15000278
APPROVED: SCALE ACCORDINGLY SHEET: OF:
3 3
B �
E
�co
.�
C
c ME
K
ri
�u
cn
W
m
rl
cl
I°
a
to
'a
ico
<
'D
c
a
°) .
cy
ru
CT
sm
G_
z
Z
C
m
m
D
n
o
O
a
00
ao
C
3]
m