HomeMy WebLinkAbout2023-08-29 Rev 4 - KC Sewer ConnectionLegendPROPERTY LINESANITARY SEWERSANITARY MH/CO8" SS @ xx%STORM DRAINAGE PIPEYD/CO/CB/CB 2/MH8" SD @ xx%FH/FDC/PIV/VALVEWATER VAULT/METERFHFDCPIVWVWATER MAIN12" DI WDo not use BlockEdit, Use LEGEND to editSITE/ STREET LIGHTINGOHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDx
SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
SDxSDxSDxSDxSDx SDx SDx SDx SDx SDx SDx SDx
SDxSDxSDxSDxSDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
SDx SDx SDx SDx SDx
SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx
SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
SEWER CONNECTIONIN OAKESDALE AVE SEOAKESDALE AVE SW8'OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPx OHPxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDx
SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
SDxSDxSDxSDxSDx SDx SDx SDx SDx SDx SDx SDx
SDxSDxSDxSDxSDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
SDx SDx SDx SDx SDx
SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx
SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx
Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx
SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx231 LF 8" PVC @ 0.8%CONNECT TO EX WATER LINEN:170940.0927E:1293974.615(1) 12" TEE (FL)(3) 12" GATE VALVE (FLxMJ)(2) 12" SLEEVES (MJ))CUT-IN PER COR STD. PLAN 300.3 (BY CITY FORCES)W/ THRUST BLOCKING PER COR STD. PLAN 300.118 LF 8" PVC @ 1.0%89 LF 8" PVC @ 1.0%70 LF 8" PVC @ 1.0%182 LF 8" PVC @ 1.0%175 LF 12" DI CL5215' WATER EASEMENT, TYP100 YEARFLOODPLAINELEVATIONBFE=20.012+9212+50(PRIVATE)(PRIVATE)(PRIVATE)(PRIVATE)MANHOLE SURVEYED ANDCONFIRMED ELEVATIONSRIM=21.15 (EX)IE=0.42 72"(IN)S (EX)IE=0.63 72"(OUT)N (EX)IE=8.78 8"(IN)WSS#03 SSMH - 48"RIM=20.37IE=10.85 8"(IN)WIE=10.75 8"(OUT)NPER COR STD. PLAN400.1 AND 401.2(PRIVATE)SS#02 SSMH - 48"RIM=20.38IE=9.87 8"(IN)SIE=9.77 8"(OUT)EPER COR STD. PLAN400.1 AND 401.2(PRIVATE)SS#04 SSMH - 48"RIM=20.36IE=12.77 8"(IN)WIE=12.67 8"(OUT)EPER COR STD. PLAN400.1 AND 401.2(PRIVATE)SS#01 SSMH - 48"RIM=21.25IE=9.58 8"(IN)WIE=9.48 8"(OUT)EPER COR STD. PLAN400.1 AND 401.115' SEWER EASEMENT, TYPCONNECT VIA LOW PROFILE DROPPER KING COUNTY DETAIL 3305-436SEE DETAIL4C4.22CONNECT TO 72" SEWER MAIN ATEXISTING MANHOLE IN OAKESDALEAVE SW PER KING COUNTYSTANDARDS. CONTRACTOR TOVERIFY ELEVATIONS PRIOR TOINSTALLATION. MATCH EX CROWNSWITH NEW PIPE CONNECTION01020401"=20'801 SECOND AVENUE, SUITE 900 (206) 343-0460 SEATTLE, WA 98104 www.cplinc.com COUGHLIN LUNDEEN PORTER S T R U C T U R A L C I V I L S E I S M I C E N G I N E E R I N G 33708STATE OF WASHINGTONREGISTEREDPROFESSIONALENGINEER CORB.BYHTOMITYAWK
A PORTION OF THE NW 1/4 OF SECTION 8, TOWNSHIP 23N, RANGE 5E, W.M.CITY OFRENTONCall Before You Dig. 8-1-1 or 1-800-424-5555 Underground Service (USA)SEATTLE SOUNDERS FC HEADQUARTERS& TRAINING CENTERRENTON, WASHINGTONSEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER
LUA22-000357 C22005747SEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER PR22-000301UTILITY PLANCONTINUED - SEE SHEET C4.08
CONTINUED - SEE SHEET C4.06S-423807 W-423807WTRP-27-4238WWP-27-4238
KING COUNTY SEWER CONFIRMATION4JAS8/29/23WCADEVELOPMENT ENGINEERINGNJanders 09/11/2023approval is subject to the conditions of approval as outlinedin the letter from KC dated 9/5/2023 titled 'SeattleSounders FC Headquarters & Training Center DirectConnection to King County 72-inch South Interceptor City ofRenton - Project PR22-000301, Civil construction PermitC22005747'
7Pollypig6Water Main Connection Tee3Side Sewer Stub Installation1Private Sewer Manhole Frame & Cover8Not Used4King County Inside Sewer Drop5Water Main Connection Cut-In2Sewer Pipe Bedding801 SECOND AVENUE, SUITE 900 (206) 343-0460 SEATTLE, WA 98104 www.cplinc.com COUGHLIN LUNDEEN PORTER E N G I N E E R I N G S E I S M I C C I V I L S T R U C T U R A L 33708STATE OF WASHINGTONREGISTEREDPROFESSIONALENGINEER CORB.BYHTOMITYAWK
A PORTION OF THE NW 1/4 OF SECTION 8, TOWNSHIP 23N, RANGE 5E, W.M.SEATTLE SOUNDERS FC HEADQUARTERS& TRAINING CENTERRENTON, WASHINGTONSEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER
LUA22-000357 C22005747SEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER PR22-000301CITY OFRENTONUTILITY DETAILSS-423812 W-423812WTRP-27-4238WWP-27-4238
KING COUNTY SEWER CONFIRMATION4JAS8/29/23WCADEVELOPMENT ENGINEERINGNJanders 09/11/2023
Sewer 1Scale: 1"=5' V. 1"=20' H5101520253020+0021+0022+0023+0024+00PROPOSEDSTORAGEFACILITYPROPOSEDGRADE12" EX STORMIE=14.1412" EX STORMIE=15.5012" EX STORMIE=16.0412" EX STORMIE=15.9112" EX STORMIE=16.0912" EX STORM X'INGIE=16.011.7'12" EX WATER(DEPTH NOT SURVEYED)IE=15.632.8'
3.6'SS#05 SSMH - 48"RIM=20.56IE=14.77 6"(IN)NWIE=14.67 8"(OUT)EPER COR STD. PLAN400.1 AND 401.2(PRIVATE)SS#04 SSMH - 48"RIM=20.36IE=12.77 8"(IN)WIE=12.67 8"(OUT)EPER COR STD. PLAN400.1 AND 401.2(PRIVATE)231 LF 8" PVC @ 0.8%182 LF 8" PVC @ 1.0%2'3.6'0.5'BASE FLOODELEVATION=20.01.5'1.9'6" WATERIE=16.601.8'(PRIVATE)(PRIVATE)(PRIVATE)89 LF 6" PVC @ 3.8%SS#05A SSCORIM=21.50IE=18.14 6"(IN)NWIE=18.14 6"(OUT)SECLEANOUT(PRIVATE)5101520253025+0026+0027+0012" EX STORMIE=15.7324" EX STORMIE=15.1490' R/W3.6'SS#03 SSMH - 48"RIM=20.37IE=10.85 8"(IN)WIE=10.75 8"(OUT)NPER COR STD. PLAN400.1 AND 401.2(PRIVATE)89 LF 8" PVC @ 1.0%4'SS#02 SSMH - 48"RIM=20.38IE=9.87 8"(IN)SIE=9.77 8"(OUT)EPER COR STD. PLAN400.1 AND 401.2(PRIVATE)SS#01 SSMH - 48"RIM=21.25IE=9.58 8"(IN)WIE=9.48 8"(OUT)EPER COR STD. PLAN400.1 AND 401.118 LF 8" PVC @ 1.0%70 LF 8" PVC @ 1.0%BASE FLOODELEVATION=20.0(PRIVATE)5'Sewer Profile 1801 SECOND AVENUE, SUITE 900 (206) 343-0460 SEATTLE, WA 98104 www.cplinc.com COUGHLIN LUNDEEN PORTER E N G I N E E R I N G S E I S M I C C I V I L S T R U C T U R A L 33708STATE OF WASHINGTONREGISTEREDPROFESSIONALENGINEER CORB.BYHTOMITYAWK
A PORTION OF THE NW 1/4 OF SECTION 8, TOWNSHIP 23N, RANGE 5E, W.M.Call Before You Dig. 8-1-1 or 1-800-424-5555 Underground Service (USA)SEATTLE SOUNDERS FC HEADQUARTERS& TRAINING CENTERRENTON, WASHINGTONSEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER
LUA22-000357 C22005747SEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER PR22-000301CITY OFRENTONSEWER PROFILESS-423813WWP-27-4238Sewer Profile 1 con'tKING COUNTY SEWER CONFIRMATION4JAS8/29/23WCAINFRASTRUCTURE ENCLOSUREASI-004JAS8/25/23WCADEVELOPMENT ENGINEERINGNJanders 09/11/2023