Loading...
HomeMy WebLinkAboutFabrication Shop Observation.City of Renton Gene Coulon Memorial Beach Park (T).Not Applicable.2023-03-20.M7221137.0015FABRICATION SHOP OBSERVATION REPORT Report Number:M7221137.0015 Service Date:03/20/23 20225 Cedar Valley Rd Ste 110 Report Date:03/22/23 Lynnwood, WA 98036-6365 425-742-9360 Client Project City of Renton WA City of Renton Gene Coulon Memorial Beach Park (T) Attn: Alan J. Wyatt 1201 Lake Washington Blvd N 1055 S Grady Way Renton, WA Renton, WA 98057-3232 Project Number: M7221137 Services: Special Inspections / Materials Testing Mayes/Terracon Rep.: Michael Virgilio Reported To:American Construction Company Contractor:American Construction Company Inc Report Distribution: (1) City of Renton WA, Alan J. Wyatt (1) American Construction Co Inc, Aaron McMahill (1) American Construction Co Inc, John Blair (1) Mayes Testing Engineers, Inc, Jim Kay Reviewed By:____________________________________ (1) WSP USA Inc, Garth Nelson, P.E. Mark Gordon Department Manager III The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. DM010, 04-29-22 Rev.3 Page 1 of 1 Permit No.: Not Applicable GENERAL INFORMATION Mayes/Terracon Consultants performed Visual and Ultrasonic testing for complete penetration welds on the City of Renton Gene Coulon Memorial Park Bridge at Rainier welding in Anacortes WA. Testing was performed on complete penetration welds on the plated sides of built-up beam members B111, B112, and B130. Inspection found the welding on these joints in compliance with AWS D1.1. See attached UT report for details. COMPLIANCE STATEMENT Based on our observations and testing, the above noted items appear to be in general accordance with the project documents. MTE 1521-2C, Rev 1, 9/16/09 Page 2 of 3 Ultrasonic Examination Report Project No.M7221137 Date:3/20/2023 Project Rento Coulon Bridge Specification:AWS D1.1 Weld Process: SMAW FCAW GMAW SAW UT Equipment:Long Transducer:Shear Transducer:Calibration Block: Model USMGO+Freq.:2.25 Freq.:2.25 IIW DSC Serial No.: GOPLS16010180 Size:1"Size:.75 x.75 Other: Decibels Discontinuity Location Weld Indication NumberTransducer Angle Indication Level Reference Level Attenuation Level Indication RatingSound Path Length Depth X Y AcceptRejectRemarks B111 70 37 X Piece p1021 to added plate-1 B111 70 37 X added plate-1 to p1018-1 B111 70 37 X p1018-1 to p1018-2 B111 70 37 X p1018-2 to p1012 B111 70 37 X p1009 to p1007-1 B111 70 37 X p1007-1-to p1007-2 B111 70 37 X p1007-2 to added plate-2 B111 70 37 X added plate-2 to p1008 B112 70 37 X p1055 to p1054-1 B112 70 37 X p1050 to p1022-1 B112 70 37 X p1050 to added plate -1 B112 70 37 X added plate -1 to p1057-1 B112 70 37 X p1057-1 top1057-2 B112 70 37 X p1022-2 to p1052 B112 70 37 X p1022-1 to p1022-2 B112 70 37 X p1022-2 to added plate 2 B130 70 37 X p10001 to p1004-1 B130 70 37 X p1004-1 to p1004-2 B130 70 37 X p1004-2 to added plate-1 Inspector:Michael Virgilio Level:III 20225 Cedar Valley Road,Suite 110 Lynnwood,WA 98036 10029 S.Tacoma Way,Suite E-2 Tacoma,WA 98499 P 425.742.9360 F 425.745.1737 P 253.584.3720 F 253.584.3707 b c d Distance a MTE 1521-2C, Rev 1, 9/16/09 Page 3 of 3 Ultrasonic Examination Report Project No.M7221137 Date:3/20/2023 Project Rento Coulon Bridge Specification:AWS D1.1 Weld Process: SMAW FCAW GMAW SAW UT Equipment:Long Transducer:Shear Transducer:Calibration Block: Model USMGO+Freq.:2.25 Freq.:2.25 IIW DSC Serial No.: GOPLS16010180 Size:1"Size:.75 x.75 Other: Decibels Discontinuity Location Weld Indication NumberTransducer Angle Indication Level Reference Level Attenuation Level Indication RatingSound Path Length Depth X Y AcceptRejectRemarks B130 70 37 X added plate-1 to p1002 B130 70 37 X p1004 to added plate-2 B130 70 37 X added plate -2 to p1003-1 B130 70 37 X p1003-1 to p1003-2 B130 70 37 X p1003-2 to p1002 B130 70 37 X p1002 to p1005 Inspector:Michael Virgilio Level:III 20225 Cedar Valley Road,Suite 110 Lynnwood,WA 98036 10029 S.Tacoma Way,Suite E-2 Tacoma,WA 98499 P 425.742.9360 F 425.745.1737 P 253.584.3720 F 253.584.3707 b c d Distance a