2023.0911_8833_Sounders HQ Practice Facility -Mechanical Set - ASI-004 - reviewed
M T= B= FSD MOD BDD FD FSD BDD M FD TOP PER FOOT PITCH PITCH PER FOOT IE BOP LC TS TI PI TL DP RS RL NG FOV FOS FOR CHS CHR CD . . EF-X ∅ R R R R - XXX XX'-XX" X X L-*-*SP*-* 1/X" 1/X" XX'-XX" XX'-XX" X-X X XX'-XX" RECT ROUND ROUND ROUND RECT ROUND RECT ROUND ROUND ROUND RECT T MECHANICAL INDEX OF DRAWINGS DRY BULB / DECIBEL AIR CONDITIONING UNIT AIRFLOW MEASURING UNIT ABOVE FINISHED FLOOR BRITISH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CONDENSER / CONDENSATE CONDENSING UNIT / CUBIC CHILLED WATER PUMP CC COOLING COIL CWP DN DMPR DEG DIA D DB DOWN DAMPER DIAMETER DEGREE DRAIN CT CU CV CP CNTFGL COND CFM CLG CHLR CIRCULATING PUMP COOLING TOWER/CURRENT SENSOR CONSTANT VOLUME CENTRIFUGAL CHILLER CEILING AC BOD BOT BTUH BDD AMS B AHU AFF BACKDRAFT DAMPER BOTTOM OF DUCT BOTTOM AIR HANDLING UNIT BOILER ABBREVIATIONS RH RELATIVE HUMIDITY UH WG WT VEL WB W UNO VAV VA VD VENT SS TOS TP TSP TYP UBD ST TCV TOD TDH SENS SF SL SP SMACNA SA UNIT HEATER WATER GAUGE WEIGHT WET BULB (TEMPERATURE) INSULATED DUCT / WATT / WIDE VARIABLE AIR VOLUME VENTILATION / VENTILATOR UNLESS NOTED OTHERWISE VELOCITY VOLUME DAMPER VALVE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION STAINLESS STEEL TOTAL STATIC PRESSURE TEMPERATURE CONTROL VALVE TOP OF STEEL UPBLAST DISCHARGE TOTAL PRESSURE TYPICAL SOUND TRAP TOP OF DUCT TOTAL DYNAMIC HEAD SUPPLY FAN / SQUARE FOOT SOUND LINE (INSIDE DUCT INSULATION ) STATIC PRESSURE SENSIBLE SUPPLY AIR MECH REF RA RF REV PL PD PT POC NO NTS OBD OSA OD OC MOD MTD NIC NC LWT LAT LB MBH HX ID IN KW HC HP HT HORIZ HVAC GPM GWB GALV MECHANICAL POINT OF CONNECTION PRESSURE DROP / PUMPED DRAIN RETURN AIR RELIEF FAN REFERENCE REVISION POST-TENSION SLAB PLENUM MOTOR OPERATED DAMPER NORMALLY CLOSED / NOISE CRITERIA NORMALLY OPEN / NUMBER OUTSIDE DIMENSION OR DIAMETER OPPOSED BLADE DAMPER NOT TO SCALE ON CENTER OUTSIDE AIR NOT IN CONTRACT MOUNTED HEATING, VENTILATING, AND AIR CONDITIONING INDIRECT DRAIN / INSIDE DIAMETER LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE THOUSAND BTU PER HOUR POUND HEAT EXCHANGER INCH KILOWATT GALLONS PER MINUTE HEATING COIL HORIZONTAL HORSEPOWER HEAT TRACE GALVANIZED GYPSUM WALLBOARD ABBREVIATIONS FSD FT FV FPM FD FCU FLTR ELEV EWT ESP EXT EXH EAT EF EER EDH ELEC ECONO EA FIRE DAMPER / FLOOR DRAIN FEET PER MINUTE FACE VELOCITY FIRE SMOKE DAMPER FEET/FAN TERMINAL UNIT FAN COIL UNIT FILTER ENERGY EFFICIENCY RATIO ELECTRIC DUCT HEATER ENTERING AIR TEMPERATURE EXTERIOR / EXTERNAL ENTERING WATER TEMPERATURE EXTERNAL STATIC PRESSURE ELECTRIC EXHAUST EXHAUST FAN ECONOMIZER ELEVATION EXHAUST AIR PIPING RS RL MAV FOV NG FOS FOR CHS CHR CD AAV SYMBOL ABBR TEMPERATURE PRESSURE TEST PLUG REFRIGERANT SUCTION REFRIGERANT LIQUID METER MANUAL AIR VENT NATURAL GAS FUEL OIL VENT FUEL OIL SUPPLY FUEL OIL RETURN FLEX FLANGE CHILLED WATER SUPPLY CHILLED WATER RETURN COOLING COIL CONDENSATE AUTOMATIC AIR VENT DESCRIPTION GENERAL NOTES W (CONTINUED) REFER TO PLANS FOR METER SERVICE 1.THE MECHANICAL SCOPE OF WORK SHALL INCLUDE WORK INDICATED ON DRAWINGS. 2.VERIFY EXISTING CONDITIONS BEFORE COMMENCING WORK ON AN EXISTING MECHANICAL SYSTEM. 3.VERIFY LOCATIONS AND DIMENSIONS OF EQUIPMENT AND COORDINATE WORK PRIOR TO START OF CONSTRUCTION. 4.COORDINATE MECHANICAL WORK WITH OTHER TRADES TO INSURE PROPER AND ADEQUATE INTERFACE OF THEIR WORK WITH THE WORK OF THIS CONTRACTOR. INSTALL MECHANICAL WORK AS HIGH AS POSSIBLE, TIGHT TO STRUCTURE ABOVE. PROVIDE ALL REQUIRED OFFSETS 5.ELEVATIONS ARE REFERENCED FROM FINISHED FLOOR, UNLESS NOTED OTHERWISE. 6.THE MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. 7.PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. 8.MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT DURING CONSTRUCTION. 9.DUCTWORK SIZES SHOWN ARE INSIDE CLEAR. ADD APPROPRIATE DIMENSION FOR INSULATION OR DUCT LINER TO OBTAIN "TOTAL" DUCT SIZE. 10. PROVIDE CABLE OPERATED DAMPERS FOR VOLUME DAMPERS OVER INACCESSIBLE CEILINGS AND SOFFITS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 11. PROVIDE TRANSITIONS AS REQUIRED TO CONNECT DUCTWORK TO AIR TERMINAL UNITS, FANS, AND OTHER MECHANICAL EQUIPMENT. 12. COORDINATE EXACT LOCATIONS OF ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH ARCHITECT PRIOR TO INSTALLATION. MOUNT WALL THERMOSTATS AT 48" AFF PER MOST RECENT VERSION OF ADA. 13. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING AND IN BRANCHES WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH AND ELSEWHERE AS NOTED ON THE DRAWINGS OR SPECIFICATIONS. 14. PROVIDE 1" THICK DUCT LINER IN RECTANGULAR SUPPLY AIR DUCTWORK WITHIN FIVE FEET DOWNSTREAM OF AIR TERMINAL UNITS UNLESS NOTED OTHERWISE. GENERAL NOTES (CONTINUED) 18. STRUCTURAL CALCULATIONS FOR MECHANICAL EQUIPMENT SHALL BE PROVIDED AS PART OF THE PERMIT SUBMITTAL TO THE CITY. STRUCTURAL CALCULATIONS SHALL BE SIGNED AND SEALED BY A WASHINGTON STATE REGISTERED STRUCTURAL ENGINEER, FOR APPROVAL BY THE AHJ. 19. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO PENETRATION OF ANY STRUCTURAL ELEMENT, IF PENETRATION IS NOT SHOWN ON STRUCTURAL DRAWINGS. 20. PROVIDE SEISMIC RESTRAINTS AND ANCHORAGE PER SMACNA AND THE BUILDING CODE FOR MECHANICAL SYSTEMS, REFERENCE STRUCTURAL. MECHANICAL CONTRACTOR SHALL INDICATE IF A DEFERRED SUBMITTAL FOR PERMITTING IS REQUESTED. 21. GENERAL CONTRACTOR SHALL PROVIDE CUTTING, FRAMING, PATCHING, SEALING AND PAINTING OF WALLS, CEILING AND FLOOR OPENINGS. THIS INCLUDES OPENINGS THOUGH AREA SEPARATION WALLS. 22. PROVIDE A CLEAR ZONE OF 42 INCHES IN FRONT OF THE ELECTRICAL EQUIPMENT. NO MECHANICAL EQUIPMENT FROM FLOOR TO CEILING CAN BE LOCATED IN THIS CLEAR ZONE, OR ABOVE THE EQUIPMENT FOOTPRINT. REFERENCE ELECTRICAL DRAWINGS FOR LOCATIONS. 23. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION, INCLUDING BUT NOT LIMITED TO: EQUIPMENT HOUSEKEEPING PADS, PENETRATION DETAILS, FLASHING AND SEALING DETAILS AND OTHER ELEMENTS OF GENERAL CONSTRUCTION. 24. PROVIDE 30-DEG BOOT OR CONICAL TEE FOR MEDIUM PRESSURE BRANCH DUCT CONNECTIONS. DO NOT USE STRAIGHT TEE FITTINGS UNLESS SPECIFICALLY INDICATED ON DRAWINGS. 25. PROVIDE MANUAL AIR VENTS AT HIGH POINTS IN HYDRONIC PIPING IF EXISTING VENTS DO NOT MEET THIS REQUIREMENT. PROVIDE DRAIN VALVES AT HYDRONIC PIPING LOW POINTS. 26. PROVIDE FLANGES OR UNIONS AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES AND OTHER COMPONENTS TO ALLOW FOR MAINTENANCE 27. PROVIDE DIELECTIC NIPPLES AT CONNECTIONS WITH DISSIMILAR MATERIALS. 28. PROVIDE PRESSURE AND TEMPERATURE TEST PORTS AT SUPPLY AND RETURN PIPING CONNECTIONS TO EQUIPMENT. 29. SIZE BALANCING/ MEASURING VALVES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. DO NOT PROVIDE VALVES LARGER THAN LINE SIZE. 30. MECHANICAL SYSTEMS SHALL BE COMMISSIONED BY A CERTIFIED COMMISSIONING PROFESSIONAL AS REQUIRED BY WSEC SECTION C408. RV REFRIGERANT VENT DUCT LINE EQUIVALENTS LEGEND DOUBLE LINESINGLE LINE DESCRIPTION GENERAL DIFFUSER/GRILLE DESIGNATION TOP OF DUCT, BOTTOM OF DUCT MOTOR OPERATED DAMPER AIR FLOW DIRECTION - AIR FLOW DIRECTION - SUPPLY FIRE DAMPER - PROVIDE ACCESS FIRE/SMOKE DAMPER - PROVIDE ACCESS CONICAL SPIN-IN TAKEOFF ROUND DUCT EQUIPMENT MARK RETURN/EXHAUST GRILLE SUPPLY GRILLE OR DIFFUSER BACKDRAFT DAMPER MANUAL VOLUME DAMPER REMOTE VOLUME DAMPER FLEXIBLE DUCTWORK DUCT END CAP ELEVATION CHANGE RISE (R) OR DROP (D) 45° CONICAL LATERAL 45° LATERAL BOOT TEE BRANCH TAKEOFF, ROUND TEE WITH TURNING VANES TRANSITION (RECTANGULAR TO ROUND) TRANSITION (ROUND TO ROUND/ RECTANGULAR TO RECTANGULAR) BRANCH TEE, RECT BRANCH TAKEOFF, RECT CONICAL TEE SPIN-IN TAKEOFF RETURN OR EXHAUST DESCRIPTIONSYMBOLABBR STR U TOP VALVE IN PIPE RISE OR DROP WYE TYPE STRAINER VERTICAL SLEEVE TOP OF PIPE ELEVATION UNION UP TH SV RV PRV DRAWING NOTE DESIGNATION THERMOMETER TEE DOWN TEE SLEEVE SOLENOID VALVE PRESSURE REDUCING VALVE ROLLING 45 DOWN REDUCING CONCENTRIC REDUCING ECCENTRIC RELIEF VALVE REDUCER POC PG IE GV POINT OF CONNECTION PRESSURE GAUGE INVERT PIPE ELEVATION PLUG PITCH RIGHT PITCH LEFT GLOBE VALVE GAS COCK GATE VALVE FLOW ARROW DN CHK DOWN CIRCUIT SETTER BUTTERFLY VALVE CHECK VALVE BV AD AD BALANCING VALVE AUTOMATIC CONTOL VALVE (3-WAY) AUTOMATIC CONTROL VALVE (2-WAY) BALL VALVE ACCESS DOOR IN CEILING ACCESS DOOR IN WALL 45° DOWN 90° ELBOW 45° ELBOW BFV NEEDLE ISOLATION VALVE WYE TYPE STRAINER WITH VALVE DETAIL/SECTION CALL-OUT AUTOMATIC INTERLOCKED 2-WAY BUTTERFLY VALVE CL-EL CENTERLINE OF PIPE ELEVATION CENTERLINE BREAK CAP BOP BOTTOM OF PIPE ELEVATION DETAIL OR ENLARGED PLAN, NUMBER FOR DETAIL, LETTER FOR ENLARGED PLAN TAG AND HOSE END RADIUS ELBOW, ROUND RADIUS ELBOW, RECT TURNING VANE ELBOW 90° ELBOW UP (SUPPLY) RADIUS ELBOW UP (RETURN/EXHAUST) RADIUS ELBOW UP (SUPPLY) 90° ELBOW DOWN (RETURN/EXHAUST) 90° ELBOW DOWN (SUPPLY) 90° ELBOW UP (RETURN/EXHAUST) ROUND DUCT UP (S/R/E) RADIUS ELBOW DOWN (RETURN/EXHAUST) RADIUS ELBOW DOWN (SUPPLY) ROUND DUCT DOWN (S/R/E) CONTROLS WALL MOUNTED TSTAT WITH CONTROL WIRE TEMPERATURE SENSOR PRESSURE INDICATOR TEMPERATURE INDICATOR LINE VOLTAGE THERMOSTAT SYMBOL DESCRIPTION DUCT PRESSURE SENSOR HWS HWR HEATING WATER SUPPLY HEATING WATER RETURN HWS HWR TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND DUCTWORK. GENERAL CONTRACOR TO PROVIDE TEMPORARY HEATING EQUIPMENT. 15. PROVIDE 1" THICK DUCT LINER IN RECTANGULAR RETURN DUCTWORK OF AIR TERMINAL UNITS, PROVIDE 1" THICK DUCT LINER IN RECTANGULAR TRANSFER AIR DUCTWORK, UNLESS NOTED OTHERWISE. 17. PROVIDE RETURN AIR BOOTS WITH 1" DUCT LINER IN ACOUSTICALLY SENSITIVE AREAS AND WHERE INDICATED ON THE DRAWINGS. T THERMOSTAT TS TEMPERATURE SENSOR AUXILIARYAUX CO2 CARBON DIOXIDE SENSOR 47780STEVEN.BU E L ERPROF E SSIONA L E N G IN EERR EGIST E R E DSTATEOFWASHINGTON © 2023 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC 11611 48TH PLACE WEST MUKILTEO, WA 98275 206.364.9900 UMCI.COM M/P CONTRACTOR UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER VENTURE CONTRACTING LLC 1518 1ST AVENUE SOUTH #400 SEATTLE, WA 98134 206.582.4500 VENTURESEATTLE.COM GENERAL CONTRACTOR PRIME ELECTRIC 3460 161ST AVE SE BELLEVUE, WA 98008 425.747.5200 PRIMEE.COM ELECTRICAL CONTRACTOR GERBER ENGINEERING 307 3RD AVE SOUTH, SUITE 510 SEATTLE, WA 98104 206.405.3510 GERBERENGINEERING.COM ELECTRICAL ENGINEER 9/11/2023 10:30:35 AM M001 LEGEND, DRAWING INDEX AND GENERAL NOTES 21032 THE SOUNDERS FC CENTER AT LONGACRES 01.27.2023 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER PERMIT SET SHEET #DESCRIPTION M001 LEGEND, DRAWING INDEX AND GENERAL NOTES M002 MECHANICAL SITE PLAN M003 PERMIT NOTES AND CALCULATIONS M004 PERMIT NOTES AND CALCULATIONS M101 MECHANICAL SCHEDULES M102 MECHANICAL SCHEDULES M103 MECHANICAL SCHEDULES M104 MATERIAL MATRICES MD111 LEVEL 1 - MECHANICAL SOUTH PLAN - DEMO MD112 LEVEL 1 - MECHANICAL NORTH PLAN - DEMO MD113 LEVEL 1 - MECHANICAL EAST PLAN - DEMO MD121 LEVEL 2 - MECHANICAL SOUTH PLAN - DEMO MD122 LEVEL 2 - MECHANICAL NORTH PLAN - DEMO MDP111 LEVEL 1 - MECHANICAL PIPING SOUTH PLAN - DEMO MDP112 LEVEL 1 - MECHANICAL PIPING NORTH PLAN - DEMO MDP121 LEVEL 2 - MECHANICAL PIPING SOUTH PLAN - DEMO MDP122 LEVEL 2 - MECHANICAL PIPING NORTH PLAN - DEMO M111 LEVEL 1 - MECHANICAL SOUTH PLAN M112 LEVEL 1 - MECHANICAL NORTH PLAN M113 LEVEL 1 - MECHANICAL EAST PLAN M121 LEVEL 2 - MECHANICAL SOUTH PLAN M122 LEVEL 2 - MECHANICAL NORTH PLAN M133 PENTHOUSE - MECHANICAL EAST PLAN M142 ROOF - MECHANICAL NORTH PLAN MP111 LEVEL 1 - MECHANICAL PIPING SOUTH PLAN MP112 LEVEL 1 - MECHANICAL PIPING NORTH PLAN MP113 LEVEL 1 - MECHANICAL PIPING EAST PLAN MP121 LEVEL 2 - MECHANICAL PIPING SOUTH PLAN MP122 LEVEL 2 - MECHANICAL PIPING NORTH PLAN MP133 PENTHOUSE - MECHANICAL PIPING EAST PLAN MP142 ROOF - MECHANICAL PIPING NORTH PLAN MS111 INFRASTRUCTURE ENCLOSURE MECHANICAL PLANS & ELEVATIONS M301 DOAS UNIT SUPPLY AND EXHAUST AIR RISER DIAGRAM M401 MECHANICAL DETAILS M402 MECHANICAL DETAILS M403 MECHANICAL DETAILS M404 MECHANICAL DETAILS M501 CONTROL DIAGRAM AND SEQUENCE M502 CONTROL DIAGRAM AND SEQUENCE M503 CONTROL DIAGRAM AND SEQUENCE M601 SECTION, ELEVATION AND ENLARGED PLANS REV DESCRIPTION DATE 50% DD 02/27/2023 PERMIT SET 04/24/2023 FOR CONSTRUCTION 05/22/2023 1 ASI-001 07/07/2023 2 ASI-004 09/12/2023 1 2 note: plans are for reference only and not reviewed as part of the civil construction permit revision. plans depicting maintenance building facilities shall be submit for review and approval in conjunction with a building permit application for said structure. CR EXISTING LONGACRES BUILDING 25-20 EXISTING PARKING TO REMAINEXISTING PARKING TO REMAIN FIELD 1 NATURAL GRASS 116 YD x 75 YD FIELD 2 NATURAL GRASS 116 YD x 75 YD FIELD 3 SYNTHETIC TURF 116 YD x 75 YD OAKESDALE AVE CONDITIONING / UTILITY SPACE NATURAL GRASS EXISTING PLANTING TO REMAIN, TYP. EXISTING WALKWAY CANOPY TO REMAIN PROPERTY LINE PROPERTY LINE ZONING = CO OVERALL SITE SF = 645,165 SF 14.81 AC EXISTING BUILDING = 61,295 SF (5 FLOORS) OVERALL = 306,475 SF ALLOWABLE = UNLIMITED NEW MAINTENANCE BUILDING = 4,000 SF LOT COVERAGE = 5.0% TOTAL FOOTPRINT = 65,295 SF BUILDING HEIGHT = 93'-8" MAINTENANCE = 15'-0" ALLOWABLE = 250' PER CO ZONING PARKING STALLS = 60 PARKING (LEASED SECURE PARKING) PLAYER PARKING AREA = 17,487 SF LEGEND: EXISTING DETENTION POND EXISTING DETENTION POND SETBACK LINE EXISTING WETLAND WETLAND BUFFER SHOWN DASHEDLOT 8 TRACT B LOT 14 TRACT A LOT 12 LOT 13 LOT 21 LOT 11 OVERALL = 5.0% 65,295SF/1,320,419SF LOT COVERAGE BREAKDOWN: TRACT B = 0.0% LOT 11 = 0.0% LOT 12 = 0.0% LOT 13 = 2.2% 4,000SF/183,925SF LOT 14 = 0.0% LOT 21 = 0.0% LOT 22 = 33.5% 61,295SF/183,925SF NOTE: TRASH HANDLING FACILITIES FOR THE OVERALL DEVELOPMENT ARE ADEQUATE TO SUPPORT ALL TRASH, RECYCLING, AND OTHER MATERIAL GENERATED THROUGH THE USE OF THE PLAYING FIELDS FIELD 4 SYNTHETIC TURF 116 YD x 75 YD EXISTING DETENTION POND REFER TO CIVIL CONSTRUCTION PERMIT FOR SCOPE OF WORK. CUP APPLICATION: LUA22-00357 CIVIL PERMIT #: PR22-000301 NEW EXTERIOR PATIO AND VIEWING PLATFORM ABOVE NIC NIC OFFICE BUILDING AREA OF WORK INCLUDE PORTIONS OF LEVEL 1 AND LEVEL 2 AND ROOF NEW INFRASTRUCTURE ENCLOSURE 1 47780STEVEN.BU E L ERPROF E SSIONA L E N G IN EERR EGIST E R E DSTATEOFWASHINGTON © 2023 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC 11611 48TH PLACE WEST MUKILTEO, WA 98275 206.364.9900 UMCI.COM M/P CONTRACTOR UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER VENTURE CONTRACTING LLC 1518 1ST AVENUE SOUTH #400 SEATTLE, WA 98134 206.582.4500 VENTURESEATTLE.COM GENERAL CONTRACTOR PRIME ELECTRIC 3460 161ST AVE SE BELLEVUE, WA 98008 425.747.5200 PRIMEE.COM ELECTRICAL CONTRACTOR GERBER ENGINEERING 307 3RD AVE SOUTH, SUITE 510 SEATTLE, WA 98104 206.405.3510 GERBERENGINEERING.COM ELECTRICAL ENGINEER 9/11/2023 10:30:49 AM M002 MECHANICAL SITE PLAN 21032 THE SOUNDERS FC CENTER AT LONGACRES 01.27.2023 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER PERMIT SET SCALE: 1" = 60'-0" MECHANICAL SITE PLAN 1 NORTH REV DESCRIPTION DATE 50% DD 02/27/2023 PERMIT SET 04/24/2023 FOR CONSTRUCTION 05/22/2023 1 ASI-004 09/12/2023 ELECTRIC HEAT TRACE SCHEDULE TAG PHT-01 MHT-01 SERVICE [1][2][1][2] LOCATION PER PLAN PER PLAN EQUIPMENT MANUFACTURER RAYCHEM RAYCHEM MODEL 3XLE2-CR 5XLE2-CT NOTES: 1. HEAT TRACE AS INDICATED ON PLANS OF MAINTENANCE SHED 2. HEAT TRACE AT CHILLED AND HOT WATER PIPES BETWEEN DOAS AND BUILDING. PERFORMANCE WATTS/FT 3 5 PHYSICAL PIPE SIZE (IN) PER PLAN PER PLAN INSULATION THICKNESS (IN) PER SCHEDULE PER SCHEDULE ACCESSORIES LINE SENSING THERMO. CONTROL -- -- POWER CONNECTION MULTIPLE POINT MULTIPLE POINT ELECTRICAL VOLT 277 277 PHASE 1 1 POWER NORMAL NORMAL END SEAL -- -- ELECTRIC TRACED PIPE LABELS -- -- NOTES 1 1 FIRE SMOKE DAMPERS 1 DOAS-1-R-01 SUPPLY FSD-1-101 FIRE SMOKE RUSKIN FSD60 -YES CLASS 1 1.5 4000 8 AIRFOIL 120V LIFE SAFETY DAMPER. 2-POS FIRE ALARM SPRING RETURN 1 DOAS-1-R-01 EXHAUST FSD-1-102 FIRE SMOKE RUSKIN FSD60 - YES CLASS 1 1.5 4000 8 AIRFOIL 120V LIFE SAFETY DAMPER. 2-POS FIRE ALARM SPRING RETURN 1 PLENUM RETURN RETURN FSD-2001 FIRE SMOKE RUSKIN FSD60 - YES CLASS 1 1.5 4000 8 AIRFOIL 120V LIFE SAFETY DAMPER. 2-POS FIRE ALARM SPRING RETURN NOTES: 1. PROVIDE TRANSITIONS TO DUCT SIZE INDICATED ON PLANS IF DUCT SIZE DIFFERS FROM SCHEDULED DAMPER. DAMPER SCHEDULE FLOOR LOCATION SYSTEM DAMPER ID DAMPER TYPE MAKE MODEL SIZE [1]FACTORY END- SWITCH LEAKAGE RATING DUTY/RATING MAX VELOCITY (FPM) MAX PRESSURE (IN. H2O) BLADES Actuator Model POWER TYPE CONTROL BY - REFERENCE ONLY CONTROL NORMAL MODE - REFERENCE ONLY APPLICATION TYPE NOTES BACKDRAFT DAMPERS 1 HYDROTHERAPY RETURN AIR BDD-1-01 COUNTERBALANCED RUSKIN CBD6 - N/A PER AMCA 500 HEAVY 3500 2 EXTRUDED ALUMINUM N/A N/A N/A BACKDRAFT DAMPER 1 INFRASTRUCTOR ENCLOSURE EXHAUST BDD-1-06 COUNTERBALANCED RUSKIN CBD6 - N/A PER AMCA 500 HEAVY 3500 2 EXTRUDED ALUMINUM N/A N/A N/A BACKDRAFT DAMPER MOTORIZED DAMPERS 1 EF-1-100 EXHAUST MOD-1-100 MOTORIZED RUSKIN CD60 - YES CLASS 1A HEAVY 6000 2 AIRFOIL 24 VAC BMS AUTO ENVELOPE DAMPER INTERLOCK DAMPER WITH EF 1 LAUNDRY MAKE UP OUTSIDE AIR MOD-1-101 MOTORIZED RUSKIN CD60 - YES CLASS 1A HEAVY 6000 2 AIRFOIL 120V NA AUTO ENVELOPE DAMPER INTERLOCK DAMPER WITH EF ROOF DOAS-1-R-01 SUPPLY MOD-R-100 MOTORIZED RUSKIN CD60 - YES CLASS 1A HEAVY 6000 2 AIRFOIL 24 VAC BMS AUTO ENVELOPE DAMPER INTERLOCK DAMPER WITH DOAS ROOF DOAS-1-R-02 EXHAUST MOD-R-101 MOTORIZED RUSKIN CD60 -YES CLASS 1A HEAVY 6000 2 AIRFOIL 24 VAC BMS AUTO ENVELOPE DAMPER INTERLOCK DAMPER WITH DOAS 1 LAUNDRY OUTSIDE AIR BDD-1-02 COUNTERBALANCED RUSKIN CBD6 - N/A PER AMCA 500 HEAVY 3500 2 EXTRUDED ALUMINUM N/A N/A N/A BACKDRAFT DAMPER 1 LAUNDRY OUTSIDE AIR BDD-1-03 COUNTERBALANCED RUSKIN CBD6 - N/A PER AMCA 500 HEAVY 3500 2 EXTRUDED ALUMINUM N/A N/A N/A BACKDRAFT DAMPER 1 LAUNDRY OUTSIDE AIR BDD-1-04 COUNTERBALANCED RUSKIN CBD6 - N/A PER AMCA 500 HEAVY 3500 2 EXTRUDED ALUMINUM N/A N/A N/A BACKDRAFT DAMPER 1 INFRASTRUCTOR ENCLOSURE EXHAUST BDD-1-05 COUNTERBALANCED RUSKIN CBD6 - N/A PER AMCA 500 HEAVY 3500 2 EXTRUDED ALUMINUM N/A N/A N/A BACKDRAFT DAMPER 3. PROVIDE WITH 1/2"x0.063" EXPANDED METAL BIRD SCREEN EQUIPMENT MANUFACTURER RUSKIN RUSKIN MODEL ELF6375DX ELF6375DX LOUVER SCHEDULE TAG L1-100 L1-101 SERVICE DRYER EXHAUST HYDROTHERAPY EXHAUST LOCATION SOUTH WALL SOUTH WALL PHYSICAL LOUVER DIMENSIONS W (IN) 48 12 LOUVER DIMENSIONS H (IN) 24 24 NOTES 1, 2 1, 2, 3 NOTES: 1. PROVIDED BY MECHANICAL CONTRACTOR 2. WATER PROOFING BY GENERAL CONTRACTOR; SEE ARCHITECTURAL PLANS FOR DETAILS FREE AREA (SQ. FT) 4.56 1.14 QUANTITY OF ACTIVE SECTIONS 1 1 PERFORMANCE AIRFLOW (CFM) 2,400 300 VELOCITY (FPM) 526 263 PRESSURE DROP (IN WG) 0.02 0.02 3. INDOOR UNIT POWERED VIA OUTDOOR UNIT, FIELD INSTALLED POWER WIRING, USE 14 GAUGE WIRE. INFRASTRUCTURE ENCLOSURE SPLIT-SYSTEM AIR-COOLED HEAT PUMP SCHEDULE TAG AC-01 INDOOR CU-01 OUTDOOR SERVICE INFRASTRUCTURE ENCLOSURE LOCATION GROUND (CU), IDF ROOM (AC) EQUIPMENT MANUFACTURER SAMSUNG FAN COIL INDOOR MODEL AC030MNTDCH/AA CONDENSING UNIT OUTDOOR MODEL AC030JXADCH/AA EFFICIENCY SEER (1) (4) 19.5 MIN WSEC SEER 13.0 NOMINAL TONS COOLING 2.5 HEATING HSPF (2) 9.2 MIN WSEC HSPF 7.7 COP 2.78 REFRIGERANT R410AOUTDOOR UNIT COOLING OPERATING RANGE (DEG F)23 - 115 OUTDOOR UNIT HEATING OPERATING RANGE (DEG F)-4 - 76 SUPPLY FAN CFM 700 ESP N/A COOLING PERFORMANCE TOTAL MBH (1) 30 SENS MBH 25.5 HEATING PERFORMANCE MBH (2) 32 CONDENSING UNIT COMPRESSOR TYPE INVERTER DRIVEN STAGES VARIABLE OUTDOOR UNIT MOP 30 OUTDOOR UNIT MCA 20.3 RLA 15.1 VOLT/PHASE 208/1 POWER NORMAL DISCONNECT BY EC MOUNTING GROUND - CONCRETE PAD SOUND PRESSURE (dBA) 50 FAN COIL FLA POWER (AMPS) 0.9 INDOOR UNIT MCA -- VOLT/PHASE 208/1 (3) MOUNTING HIGH WALL SOUND PRESSURE (dBA) 37/45 PHYSICAL FAN COIL WEIGHT (LBS) 40.57 FAN COIL DIMENSIONS W X D X H (IN X IN X IN) 41-1/2 x 8-7/16 x 11-3/4 CONDENSATE DRAIN PIPE SIZE (IN) 1 CONDENSER WEIGHT (LBS) 154.3 CONDENSER DIMENSIONS W X D X H (IN X IN X IN) 34-5/8 x 31-3/8 x 12-3/16 1" THROWAWAYFILTERS -- VIBRATION ISOLATORS SEE ISOLATOR SCHEDULE SIMPLE MA CONTROLLER YES LOW AMBIENT KIT TO 0 F -- CONDENSATE PUMP ASSEMBLY YES WIND BAFFLE YES CONDENSATE SENSOR UNIT INTERFACE NOTES: NOTES: 1. FOR COOLING, RATINGS AT INDOOR CONDITIONS OF 80/67 F DB/WB, OUTDOOR CONDITIONS OF 95/75 F DB/WB.2. FOR HEATING, RATINGS AT INDOOR CONDITIONS OF 70/60 F DB/WB, OUTDOOR CONDITIONS OF 47/43 F DB/WB. LIQUID LINE (IN) 3/8 VAPOR LINE (IN) 5/8 MAX PIPE LENGTH (FT) 164 MAX PIPE ELEVATION CHANGE (FT) 98 MAXIMUM BENDS -- CONTROLS - REFERENCE ONLY NORMAL MODE AUTO CONTROLS BY STANDALONE ACCESSORIES EQUIPMENT MANUFACTURER QMARK MODEL MUH03 71 HEATING PERFORMANCE NOTES: 1. RECESSED WALL INSTALLATION 2. PROVIDE WITH OPTIONAL MOUNTING BRACKET BTU/HR 10,200 INPUT KW 3 STEPS 1 ELECTRICAL --FURNISHED/INSTALLED MC/EC DISCONNECT BY EC --FURNISHED/INSTALLED EC/EC CONTROLS - REFERENCE ONLY AMPS 11 VOLT 277 PHASE 1 POWER NORMAL STARTER FACTORY MTD NORMAL MODE AUTO CONTROLS BY STANDALONE PHYSICAL WEIGHT (LBS) 27 INFRASTRUCTURE ENCLOSURE ELECTRIC UNIT HEATER SCHEDULE TAG EH-01 SERVICE IRRIGATION ROOM LOCATION IRRIGATION ROOM LENGTH (IN) 7-1/2 WIDTH (IN) 14 HEIGHT (IN) 16 NOTES:2 INFRASTRUCTURE ENCLOSURE FAN SCHEDULE TAG SEF-01 SERVICE IRRIGATION ROOM LOCATION IRRIGATION ROOM EQUIPMENT MANUFACTURER GREENHECK MODEL SQ-70VG FAN TYPE INLINE DRIVE BELT WHEEL TYPE CENTRIFUGAL WHEEL DIAMETER (IN) NOTES 1 NOTES: 1. FAN MOTORS MUST MEET 2018 WSEC MINIMUM EFFICIENCIES. PERFORMANCE CFM 170 ESP 0.25 RPM 1550 ELECTRICAL BHP 0.03 HP 1/15 VOLT/PHASE 115/1 POWER NORMAL STARTER EC MOTOR PHYSICAL WEIGHT (LBS) 34 DISCHARGE POSITION HORIZONTAL ARR. SIZE W X L X H (IN) 14X15X14 --FURNISHED/INSTALLED MC/EC DISCONNECT BY EC --FURNISHED/INSTALLED EC/EC CONTROLS - REF ONLY CONTROL BY THERMOSTAT ACCESSORIES SPEED CONTROL EC VIBRATION ISOLATORS PER SCHEDULE BACKDRAFT DAMPERS NA MOTOR GUARD NA EQUIPMENT MANUFACTURER RUSKIN RUSKIN MODEL ELF6375DX ELF6375DX INFRASTRUCTURE ENCLOSURE LOUVER SCHEDULE TAG SL-01 SL-02 SERVICE IRRIGATION ROOM IRRIGATION ROOM LOCATION IRRIGATION ROOM IRRIGATION ROOM NOTES 1, 2, 3 1, 2, 3 NOTES: 1. PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR 2. WATER PROOFING BY GENERAL CONTRACTOR; SEE ARCHITECTURAL PLANS FOR DETAILS 3. PROVIDE WITH 1/2"x0.063" EXPANDED METAL BIRD SCREEN PHYSICAL TOTAL OPENING DIMENSION (H; in) 12 12 TOTAL OPENING DIMENSION (W; in) 12 12 FREE AREA/ ACTIVE SECTION (SQ. FT) 0.36 0.36 QUANTITY OF ACTIVE SECTIONS 1 1 ACTIVE FREE AREA (SQ. FT) 0.36 0.36 PERFORMANCE AIRFLOW (CFM) 170 100 VELOCITY (FPM) 472 323 PRESSURE DROP (IN WG) 0.05 0.015 SECTION DIMENSIONS (H; in) 12 12 SECTION DIMENSIONS (W; in) 12 12 ACTIVE DIMENSIONS (W; in) [1] 12 12 ACTIVE DIMENSIONS (H; in) [1] 12 12 N1 FLOWBAR - HIGH THROW Price Industries AS-10 1-SLOT ALUMINUM SURFACE Border 22C PER PLAN X 3.75" WIDE 8 190 8 22 WHITE 6 NOTES: 1. PROVIDE PLENUM CAN FOR DUCTED SYSTEM IN CEILING APPLICATION (NOT REQUIRED FOR SIDEWALL APPLICATION); OR PROVIDE SOUND BOOT AS INDICATED ON PLANS. 2. DIFFUSER OR GRILLE MAY ALSO BE USED FOR HARDLID APPLICATIONS WHERE A PRICE "APF" MOUNT FRAME IS PROVIDED, FRAME AS INDICATED ON PLANS. APF PROVIDES ACCESS ABOVE CEILING. 3. FOR LIMITED CEILING HEIGHT APPLICATIONS, PROVIDE PLENUM CAN WITH BRANCH DUCT SIZED SIDE INLET, OTHERWISE PROVIDE SQUARE TO ROUND TRANSITION WITH BRANCH DUCT SIZED TOP INLET. G1 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 10X10 8X8 275 PER PLAN 19 WHITE 1. 4 G2 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 12X12 10X10 360 PER PLAN 16 WHITE 1. 4 G3 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 14X14 12X12 540 PER PLAN 18 WHITE 1. 4 G4 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 16X16 14X14 710 PER PLAN 19 WHITE 1. 4 G5 SUPPLY GRILLE Price Industries 520 DOUBLE DEF STEEL SURFACE BORDER TYPE 1 30X16 28X14 1220 PER PLAN 17 WHITE 1. 4 C1 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM LAY-IN BORDER TYPE 3 24x12 22X10 600 PER PLAN <12 WHITE 1, 2 C2 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM LAY-IN BORDER TYPE 3 24x24 22X22 1200 PER PLAN <12 WHITE 1, 2 C3 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM LAY-IN BORDER TYPE 3 24x48 22X46 2400 PER PLAN <12 WHITE 1, 3 C4 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM SURFACE BORDER TYPE 1 26x14 24x12 600 PER PLAN <12 WHITE 1 C5 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM SURFACE BORDER TYPE 1 52x48 50x46 11000 PER PLAN 27 WHITE 1 C6 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM SURFACE BORDER TYPE 1 22x20 20x18 700 PER PLAN <12 WHITE 1 C7 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM SURFACE BORDER TYPE 9 24x48 22X46 2400 PER PLAN <12 WHITE 1 C8 RETURN GRILLE Price Industries 80 EGGCRATE ALUMINUM SURFACE BORDER TYPE 9 24x48 22X46 2400 PER PLAN <12 WHITE 1 E1 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 10X10 8X8 100 6 <10 WHITE 1 E2 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 12X12 10X10 210 8 <10 WHITE 1 E3 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 14X12 12X10 275 PER PLAN 17 WHITE 1 E4 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 14X14 12X12 375 10 10 WHITE 1 E5 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 16X16 14X14 550 12 27 WHITE 1 E6 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 20X16 18X14 800 PER PLAN 14 WHITE 1 E7 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 20X18 18X16 910 PER PLAN 14 WHITE 1 E8 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 26X14 24X12 910 PER PLAN 14 WHITE 1 E9 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 42X12 40X10 1200 PER PLAN 27 WHITE E10 EXHAUST GRILLE Price Industries 530 SINGLE DEF STEEL SURFACE BORDER TYPE 1 38X16 36X14 1400 PER PLAN 27 WHITE 1 GRILLE, REGISTER AND DIFFUSER SCHEDULE EQUIP. SERVICE MANUFACTURER MODEL DESCRIPTION ID NO. STYLE MATERIAL FRAME FRAME MODEL FACE SIZE NECK SIZE MAX CFM BRANCH DUCT NC COLOR NOTES A1 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 8X8 100 6 <15 WHITE 2, 3 A2 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 10X10 210 8 <15 WHITE 3, 5 A3 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 12X12 375 10 <15 WHITE 3, 5 A4 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 14X14 550 12 18 WHITE 2, 3 A5 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL LAY-IN BORDER TYPE 3 24x24 16X16 700 14 19 WHITE 3, 5 B1 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 13-9/16x13-916 8X8 100 6 <15 WHITE 5 B2 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 15-9/16x15-9/16 10X10 210 8 <15 WHITE 5 B3 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 17-9/16x17-9/16 12X12 375 10 <15 WHITE 5 B4 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 19-9/16x19-9/16 14X14 550 12 18 WHITE 5 B5 CEILING DIFFUSER Price Industries SMCD MODULAR STEEL SURFACE BORDER TYPE 1 22X22 16X16 700 14 19 WHITE 5 HEATING WATER UNIT HEATER SCHEDULE TAG HWUH1-100 SYSTEM AHU2001 SERVICE 20011UHF-4 LOCATION EQUIPMENT 155 EQUIPMENT MANUFACTURER MODINE MODEL HCH 195 MOUNTING SUSPENDED SUPPLY FAN MAX FAN AIRFLOW (CFM) 1,830 ESP @ MAX (IN WC) (1) 0 SPEED (RPM) 1,075 DRIVE TYPE DIRECT NOTES NOTES: FAN ISOLATION TYPE SEE SCHEDULE MAXIMUM MOUNTING HEIGHT (FT) 11 HEATING WATER COIL TOTAL HEATING (MBH) 185.48 EWT (DEG F) 155 LWT (DEG F) 135 WATER FLOW (GPM) 10.80 WATER PRESSURE DROP (FT PD) 5.20 EAT (DEG F) 24 LAT (DEG F) 110 ROWS NA FINS PER INCH NA AIR PRESSURE DROP (IN WC) NA CONTROL VALVE TYPE 2-WAY DISCONNECT BY EC PHYSICAL OPERATING WEIGHT (LBS) 93 DIMENSIONS - L X W X H (IN X IN X IN) 26.5 X 26.5 X 18.2 HEATING COIL PIPING IN/OUT (IN/IN) 3/4 ACCESSORIES MOTOR GUARD ELECTRICAL MOTOR TYPE ENCLOSED AIR OVER W/TERMAL OVERLOAD HP 1/6 POWER NORMAL VOLTS/PHASE 120/1 MCA 2.3 MOCP 15 STARTER BY EC 47780STEVEN.BU E L ERPROF E SSIONA L E N G IN EERR EGIST E R E DSTATEOFWASHINGTON © 2023 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC 11611 48TH PLACE WEST MUKILTEO, WA 98275 206.364.9900 UMCI.COM M/P CONTRACTOR UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER VENTURE CONTRACTING LLC 1518 1ST AVENUE SOUTH #400 SEATTLE, WA 98134 206.582.4500 VENTURESEATTLE.COM GENERAL CONTRACTOR PRIME ELECTRIC 3460 161ST AVE SE BELLEVUE, WA 98008 425.747.5200 PRIMEE.COM ELECTRICAL CONTRACTOR GERBER ENGINEERING 307 3RD AVE SOUTH, SUITE 510 SEATTLE, WA 98104 206.405.3510 GERBERENGINEERING.COM ELECTRICAL ENGINEER 9/18/2023 1:55:08 PM M103 MECHANICAL SCHEDULES 21032 THE SOUNDERS FC CENTER AT LONGACRES 01.27.2023 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER PERMIT SET REV DESCRIPTION DATE 50% DD 02/27/2023 PERMIT SET 04/24/2023 FOR CONSTRUCTION 05/22/2023 1 ASI-001 07/07/2023 2 ASI-004 09/12/2023 3 UMC RFI-12 09/12/2023 4 PERMIT REVISIONS #3 09/13/2023 1 1 1 1 1 2 2 2 2 2 2 2 SL-02 CU-01 3/8"RL BELOW ROOF 5/6"RG BELOW ROOF 4 M401 CU-01 SEF-02 AC-01 SL-02 3/4" COND TO HUB DRAINS 36"x60"x4" HOUSEKEEPING CONCRETE PAD SL-01 BDD-1-05 8x8 COVER WITH MESH T BDD-1-06 EH-01 GRAVEL PAD RE: CIVIL INFRASTRUCTURE SHED PARKING LOT RE: CIVIL 33' - 6"9' - 2"RE: CIVIL47780STEVEN.BU E L ERPROF E SSIONA L E N G IN EERR EGIST E R E DSTATEOFWASHINGTON © 2023 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 406 OCCIDENTAL AVENUE SOUTH SEATTLE, WA 98104 SOUNDERSFC.COM TENANT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM LANDSCAPE COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER UMC 11611 48TH PLACE WEST MUKILTEO, WA 98275 206.364.9900 UMCI.COM M/P CONTRACTOR UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM OWNER / DEVELOPER VENTURE CONTRACTING LLC 1518 1ST AVENUE SOUTH #400 SEATTLE, WA 98134 206.582.4500 VENTURESEATTLE.COM GENERAL CONTRACTOR PRIME ELECTRIC 3460 161ST AVE SE BELLEVUE, WA 98008 425.747.5200 PRIMEE.COM ELECTRICAL CONTRACTOR GERBER ENGINEERING 307 3RD AVE SOUTH, SUITE 510 SEATTLE, WA 98104 206.405.3510 GERBERENGINEERING.COM ELECTRICAL ENGINEER 9/11/2023 10:30:52 AM MS111 INFRASTRUCTURE ENCLOSURE MECHANICAL PLANS & ELEVATIONS 21032 THE SOUNDERS FC CENTER AT LONGACRES 01.27.2023 UMC 1901 OAKESDALE AVENUE SW RENTON, WA 98057 STEVE BUELER PERMIT SET SCALE: 1/8" = 1'-0" MAINTENANCE SHED NORTH ELEVATION 3 REV DESCRIPTION DATE 50% DD 02/27/2023 PERMIT SET 04/24/2023 FOR CONSTRUCTION 05/22/2023 1 ASI-004 09/12/2023 SCALE: 1/4" = 1'-0" ENCLOSURE MECHANICAL PLAN 1 SCALE: 1/4" = 1'-0" ENCLOSURE ROOF MECHANICAL PLAN 2 SCALE: 1/16" = 1'-0" ENCLOSURE MECHANICAL SITE PLAN 5 1