HomeMy WebLinkAboutMFP23003667.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP23003667
IVR Number: 23003667
Permit Information
Permit Name: P.016300
Address/Location:07/12/2023Application Date:2423049008Parcel Number: 651 MONSTER RD SW
Permit Type:10/12/2023Issue Date:Franchise
Permit Work Class:10/11/2024Expiration Date:Minor Utility
Job Number: P.016300Franchise Type:Telephone
Description: Lumen to access MH668, HH601, and HH UNK. This will not be a disturbance of surface.
Contacts
Name Address PhoneTypeBilling
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549ApplicantX
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Jesse Patjens
CenturyLink / Lumen
23315 66th Ave S
Kent, WA 98032
Contact
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549Contact
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐Electronic Copy of the TCP Application
☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
Tawnya Longfellow
22517 88th ave S Kent/WA 98031
Project Name: P.016300 Permit #:
Site Address: 651 Monster Rd SW
Work Date: From _____________ To _____________ Work Time: Start ______________ End______________
Construction Company: Northsky Communications
Lumen to access MH668, HH601, and HH UNK. This will not be a disturbance of surface.
8/12/2023 10/12/2023
MFP23003667
Monday - Friday 8:00AM - 3:00PM
Scott Warlick CED 7/27/2023
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
Austin Sweeney
Austin Sweeney 7/12/2023
N
TRAFFIC CONTROL PLAN
JOB # P. 016300 C. 45
PERMIT #
Comments:
ACCESS MH-668 LOCATED OFF ROADWAY.
RIGHT-LANE CLOSURE NORTHBOUND
OAKESDALE AVE SW. USE ARROW BOARD.
DRIVEWAYS REMAIN OPEN/ACCESSIBLE.
SIDEWALKS REMAIN OPEN/ACCESSIBLE.
SPOTTER WILL ASSIST AT WORK AREA.
OAKESDALE AVE SW @ MONSTER RD SW
MH-668 ACCESS
RIGHT-LANE CLOSURE
LEGENDARROW BOARD CONES
SPOTTERS SPOTTER WORK AREA
WORK TRUCK
Comments: SIGN SPACINGMPH "X"20 > 100'25-30 200'35-40 350'
45+ 500'Jeffrey Hubbard
Comments: CHANNELIZATION SPACING
MPH TAPER TANGENT25 / 30 20' 40'35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100'
NOT TO
SCALE Comments:
MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12'SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600
Designed For: LUMEN
Project # P. 016300 C. 45
Jeffrey D. Hubbard
Traffic Control Supervisor
WA TCS # ES2000151
Draw Date: 9/22/2023
Phone 253-737-5198
jhubbard.tcp@gmail.com
_______________________
Date:9/22/2023 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:P. 016300 C. 45CERT:WA TCS # ES2000151 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be determined by City of RENTON.
TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM)
ISLAND121212
1212OAKESDALE AVE SW
OAKESDALE
AVE SW
X
350' +-X
350' +-X
350' +-ROADWORKAHEADW20-1W4-2RIGHT LANECLOSEDAHEADW20-5ARROWBOARD
SPOTTERS
SIDEWALK
MH-668
ACCESS
L
245+-
x350'+-ROADWORKAHEADW20-1SPEEDLIMIT
35
SPEED
LIMIT
35
WORK AREA
12' X ~60'
MONSTER RD SW
www.invarion.com
MFP23003667
NTRAFFIC CONTROL PLAN
JOB # P. 016300 C. 45
PERMIT #
Comments:
ACCESS HH-601 OFF ROADWAY.
THIS WILL BE SHOULDER WORK.
TRAFFIC FLOW IS NOT IMPACTED.
SIDEWALK REMAINS ACCESSIBLE.
SPOTTER ASSISTS PEDESTRIANS.
COORDINATE WITH BUSINESS FOR
PROPERTY ACCESS PRIOR TO WORK.
MONSTER RD SW @ OAKESDALE AVE SW
HH-601 ACCESS
SHOULDER WORK
LEGEND
CONES CROSSWALK
S SPOTTER WORK AREA
WORK TRUCK
SPEEDLIMIT
35 DEAD ENDPARKING
N
O
FR
O
M
TOTO
W
A
W
A
Y
A
R
E
A
PH
O
N
E
6
8
4
-54
4
4
YO
U
R
C
O
M
P
A
N
Y
N
A
M
E
5
5
5
-55
5
5
P
A
R
K
I
N
G
11
11
1111111111
1111111111
OAKESDALE AVE SWOAKESDALE AVE SWMONSTER RD SW
SPEEDLIMIT
30
SPEEDLIMIT
35
SHOULDERWORKW21-5X350' +-ROADWORKAHEAD
W20-1X350' +-ROADWORKAHEADW20-1X
200' +
-
R
O
A
D
W
O
R
K
A
H
E
A
D
W
2
0
-1
HH-601
ACCESS
WORK ZONE
12' X ~50'
SIDEWALK SIDEWALKSIDEWALKSIDEWALKSIDEWALKSPOTTERS
Comments: SIGN SPACINGMPH "X"20 > 100'25-30 200'35-40 350'
45+ 500'Jeffrey Hubbard
Comments: CHANNELIZATION SPACING
MPH TAPER TANGENT25 / 30 20' 40'35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100'
NOT TO
SCALE Comments:
MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12'SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600
Designed For: LUMEN
Project # P. 016300 C. 45
Jeffrey D. Hubbard
Traffic Control Supervisor
WA TCS # ES2000151
Draw Date: 9/22/2023
Phone 253-737-5198
jhubbard.tcp@gmail.com
_______________________
Date:9/22/2023 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:P. 016300 C. 45CERT:WA TCS # ES2000151 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be determined by City of RENTON.
TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM)
www.invarion.com
MFP23003667
NComments:
ACCESS HH LOCATED OFF ROADWAY.
ONE-LANE TWO-WAY OPERATION.
FLAGGERS ASSIST WITH DRIVEWAYS.
FLAGGERS ASSIST WITH BICYCLES.
FLAGGERS ASSIST WITH PEDESTRIANS.
SPOTTER WILL ASSIST AT WORK AREA.
MONSTER RD SW @ OAKESDALE AVE SW
HH ACCESS
ONE-LANE TWO-WAY OPERATION
LEGEND
CONES FLAGGER
SPOTTERS SPOTTER WORK AREA
WORK TRUCK
Comments: SIGN SPACINGMPH "X"20 > 100'25-30 200'35-40 350'
45+ 500'Jeffrey Hubbard
Comments: CHANNELIZATION SPACING
MPH TAPER TANGENT25 / 30 20' 40'35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100'
NOT TO
SCALE Comments:
MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12'SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600
TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM)
Date:9/22/2023 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:P. 016300 C. 45CERT:WA TCS # ES2000151 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be determined by City of RENTON.
DRI
V
E
W
A
Y
DRI
V
E
W
A
Y
Designed For: LUMEN
Project # P. 016300 C. 45
Jeffrey D. Hubbard
Traffic Control Supervisor
WA TCS # ES2000151
Draw Date: 9/22/2023
Phone 253-737-5198
jhubbard.tcp@gmail.com
_______________________
X
200' +-
X
200' +-
X
200' +-ROADWORKAHEADW20-1PLACE IN ADVANCE OF WORK ZONEW20-7ONE LANEROADAHEADW20-4X
200' +-
X
200' +-
X
200' +-ROADWORKAHEADW20-1W20-7ONE LANEROADAHEADW20-4TRAFFIC CONTROL PLAN
JOB # P. 016300 C. 45
PERMIT #
HH
ACCESS
WORK AREA
12' X ~50'
1111 11113RD-FLAGGER AS NEEDED FOR DRIVEWAYS AND
TO MAINTAIN PROPER
SIGHT-LINES FOR SAFETY
MONSTER RD SW
MONSTER RD SWSPEEDLIMIT30
SPEEDLIMIT30SIDEWALK
SPOTTERS
SIDEWALK
OAKESDALE AVE SW
SPOTTER TO ASSIST
AT WORK AREA
www.invarion.com
MFP23003667
MH 668
HH 601
LUMEN TO ACCESS MH668,
HH601, & HH UNK. NO
DISTURBANCE TO SURFACE.
651 MONSTER RD. SW.
PARCEL#-2423049008
HH UNK
LUMEN TO ACCESS MH668,
HH601, & HH UNK. NO
DISTURBANCE TO SURFACE.
1201 MONSTER RD. S.W.
PARCEL#-2423049123
N
MONSTER RD. S.W.
CURRENT FIELD PHOTO
MH 668
HH 601
N
CURRENT FIELD PHOTO
MONSTER RD. S.W.
ACCESS RD.
HH UNK
N
CURRENT FIELD PHOTO