Loading...
HomeMy WebLinkAboutMFP23003667.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23003667 IVR Number: 23003667 Permit Information Permit Name: P.016300 Address/Location:07/12/2023Application Date:2423049008Parcel Number: 651 MONSTER RD SW Permit Type:10/12/2023Issue Date:Franchise Permit Work Class:10/11/2024Expiration Date:Minor Utility Job Number: P.016300Franchise Type:Telephone Description: Lumen to access MH668, HH601, and HH UNK. This will not be a disturbance of surface. Contacts Name Address PhoneTypeBilling Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549ApplicantX Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Jesse Patjens CenturyLink / Lumen 23315 66th Ave S Kent, WA 98032 Contact Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549Contact Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Tawnya Longfellow 22517 88th ave S Kent/WA 98031 Project Name: P.016300 Permit #: Site Address: 651 Monster Rd SW Work Date: From _____________ To _____________ Work Time: Start ______________ End______________ Construction Company: Northsky Communications Lumen to access MH668, HH601, and HH UNK. This will not be a disturbance of surface. 8/12/2023 10/12/2023 MFP23003667 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 7/27/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Austin Sweeney Austin Sweeney 7/12/2023 N TRAFFIC CONTROL PLAN JOB # P. 016300 C. 45 PERMIT # Comments: ACCESS MH-668 LOCATED OFF ROADWAY. RIGHT-LANE CLOSURE NORTHBOUND OAKESDALE AVE SW. USE ARROW BOARD. DRIVEWAYS REMAIN OPEN/ACCESSIBLE. SIDEWALKS REMAIN OPEN/ACCESSIBLE. SPOTTER WILL ASSIST AT WORK AREA. OAKESDALE AVE SW @ MONSTER RD SW MH-668 ACCESS RIGHT-LANE CLOSURE LEGENDARROW BOARD CONES SPOTTERS SPOTTER WORK AREA WORK TRUCK Comments: SIGN SPACINGMPH "X"20 > 100'25-30 200'35-40 350' 45+ 500'Jeffrey Hubbard Comments: CHANNELIZATION SPACING MPH TAPER TANGENT25 / 30 20' 40'35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12'SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 Designed For: LUMEN Project # P. 016300 C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # ES2000151 Draw Date: 9/22/2023 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ Date:9/22/2023 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:P. 016300 C. 45CERT:WA TCS # ES2000151 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be determined by City of RENTON. TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM) ISLAND121212 1212OAKESDALE AVE SW OAKESDALE AVE SW X 350' +-X 350' +-X 350' +-ROADWORKAHEADW20-1W4-2RIGHT LANECLOSEDAHEADW20-5ARROWBOARD SPOTTERS SIDEWALK MH-668 ACCESS L 245+- x350'+-ROADWORKAHEADW20-1SPEEDLIMIT 35 SPEED LIMIT 35 WORK AREA 12' X ~60' MONSTER RD SW www.invarion.com MFP23003667 NTRAFFIC CONTROL PLAN JOB # P. 016300 C. 45 PERMIT # Comments: ACCESS HH-601 OFF ROADWAY. THIS WILL BE SHOULDER WORK. TRAFFIC FLOW IS NOT IMPACTED. SIDEWALK REMAINS ACCESSIBLE. SPOTTER ASSISTS PEDESTRIANS. COORDINATE WITH BUSINESS FOR PROPERTY ACCESS PRIOR TO WORK. MONSTER RD SW @ OAKESDALE AVE SW HH-601 ACCESS SHOULDER WORK LEGEND CONES CROSSWALK S SPOTTER WORK AREA WORK TRUCK SPEEDLIMIT 35 DEAD ENDPARKING N O FR O M TOTO W A W A Y A R E A PH O N E 6 8 4 -54 4 4 YO U R C O M P A N Y N A M E 5 5 5 -55 5 5 P A R K I N G 11 11 1111111111 1111111111 OAKESDALE AVE SWOAKESDALE AVE SWMONSTER RD SW SPEEDLIMIT 30 SPEEDLIMIT 35 SHOULDERWORKW21-5X350' +-ROADWORKAHEAD W20-1X350' +-ROADWORKAHEADW20-1X 200' + - R O A D W O R K A H E A D W 2 0 -1 HH-601 ACCESS WORK ZONE 12' X ~50' SIDEWALK SIDEWALKSIDEWALKSIDEWALKSIDEWALKSPOTTERS Comments: SIGN SPACINGMPH "X"20 > 100'25-30 200'35-40 350' 45+ 500'Jeffrey Hubbard Comments: CHANNELIZATION SPACING MPH TAPER TANGENT25 / 30 20' 40'35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12'SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 Designed For: LUMEN Project # P. 016300 C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # ES2000151 Draw Date: 9/22/2023 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ Date:9/22/2023 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:P. 016300 C. 45CERT:WA TCS # ES2000151 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be determined by City of RENTON. TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM) www.invarion.com MFP23003667 NComments: ACCESS HH LOCATED OFF ROADWAY. ONE-LANE TWO-WAY OPERATION. FLAGGERS ASSIST WITH DRIVEWAYS. FLAGGERS ASSIST WITH BICYCLES. FLAGGERS ASSIST WITH PEDESTRIANS. SPOTTER WILL ASSIST AT WORK AREA. MONSTER RD SW @ OAKESDALE AVE SW HH ACCESS ONE-LANE TWO-WAY OPERATION LEGEND CONES FLAGGER SPOTTERS SPOTTER WORK AREA WORK TRUCK Comments: SIGN SPACINGMPH "X"20 > 100'25-30 200'35-40 350' 45+ 500'Jeffrey Hubbard Comments: CHANNELIZATION SPACING MPH TAPER TANGENT25 / 30 20' 40'35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12'SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM) Date:9/22/2023 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:P. 016300 C. 45CERT:WA TCS # ES2000151 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be determined by City of RENTON. DRI V E W A Y DRI V E W A Y Designed For: LUMEN Project # P. 016300 C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # ES2000151 Draw Date: 9/22/2023 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ X 200' +- X 200' +- X 200' +-ROADWORKAHEADW20-1PLACE IN ADVANCE OF WORK ZONEW20-7ONE LANEROADAHEADW20-4X 200' +- X 200' +- X 200' +-ROADWORKAHEADW20-1W20-7ONE LANEROADAHEADW20-4TRAFFIC CONTROL PLAN JOB # P. 016300 C. 45 PERMIT # HH ACCESS WORK AREA 12' X ~50' 1111 11113RD-FLAGGER AS NEEDED FOR DRIVEWAYS AND TO MAINTAIN PROPER SIGHT-LINES FOR SAFETY MONSTER RD SW MONSTER RD SWSPEEDLIMIT30 SPEEDLIMIT30SIDEWALK SPOTTERS SIDEWALK OAKESDALE AVE SW SPOTTER TO ASSIST AT WORK AREA www.invarion.com MFP23003667 MH 668 HH 601 LUMEN TO ACCESS MH668, HH601, & HH UNK. NO DISTURBANCE TO SURFACE. 651 MONSTER RD. SW. PARCEL#-2423049008 HH UNK LUMEN TO ACCESS MH668, HH601, & HH UNK. NO DISTURBANCE TO SURFACE. 1201 MONSTER RD. S.W. PARCEL#-2423049123 N MONSTER RD. S.W. CURRENT FIELD PHOTO MH 668 HH 601 N CURRENT FIELD PHOTO MONSTER RD. S.W. ACCESS RD. HH UNK N CURRENT FIELD PHOTO