Loading...
HomeMy WebLinkAboutMFP23004975.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23004975 IVR Number: 23004975 Permit Information Permit Name: P.167431 - EMERGENCY WORK Address/Location:09/29/2023Application Date:0823059217Parcel Number: 800 GARDEN AVE N Permit Type:10/18/2023Issue Date:Franchise Permit Work Class:10/17/2024Expiration Date:Minor Utility Job Number: P.167431Franchise Type:Telephone Description: EMERGENCY WORK Lumen to replace stolen cable from P1 to P5. At P1 expose buried cable and place new vault next to pole. At P5 open sidewalk to expose buried cable, and access HH800 for splicing. This will be a disturbance of surface with restoration. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Stephen Neumann Fibe Solutions 604 W Meeker St., Suite 103 KENT, WA 98032 C: (425) 753-1916Applicant Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549ApplicantX Nathan Macleod Lumen 7850 S Trafton St, Bldg B Tacoma, WA 98409 C: (253) 583-6283Applicant Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549Contact Jesse Patjens CenturyLink / Lumen 23315 66th Ave S Kent, WA 98032 Contact Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Tawnya Longfellow 22517 88th ave S Kent/WA 98031 Project Name: P.167431 Permit #: Site Address: 800 Garden Ave N Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Northsky Communications 10/2 10/10 EMERGENCY WORK - Lumen to replace stolen cable from P1 to P5. At P1 expose buried cable and place new vault next to pole. At P5 open sidewalk to expose buried cable, and access HH800 for splicing. This will be a disturbance of surface with restoration. MFP23004975 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 10/18/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Austin Sweeney Austin Sweeney 9/29/2023 Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Cover Sheet 1:50 Scope of Work: Emergency Pedestal, Handhole & Fiber Installation Traffic Control Plan: Cover Sheet (1) All spacing may be adjusted to accommodate interchange ramps,at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadwayconditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR ASPER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane WidthFeet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570645 730 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes.6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-grade intersections and/or driveways.9. Traffic Control Supervisor required for ROW impacts.All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. Renton KingP.167431 98057 X HH 800 SHEET 1 & 2 SHEET 3 & 4 POLE 1A0509541 POLE 2 A0509542 POLE 3 A0509543 POLE 5 A0509545POLE 4 A0509544 www.invarion.comNight work is granted on a case by case basis. Please call into the inspection line @425-430-7203 to request an inspector for night work. Imagery and map data ©2023, Google X 10' 7' 10'35' N 8TH ST25MPH 800 GARDEN AV N GARDEN AV N25MPH SIDEWALKCLOSED R9-9 DETOUR M4-9b DETOUR M4-9b DETOUR M4-9b DETOUR M4-9b ROAD WORKAHEAD W20-1 LB MATCHLINE SHEET 210' 10' SIDEWALK CLOSED CROSS HERE R9-11a(L) SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(R) LIGHT PLANT LIGHT PLANT POLE 1A0509541 POLE 2 A0509542 POLE 3 A0509543 Legend Cone Light Plant X New Ped Pedestrian Detour Pole Sign Stand Traffic Light Work Area Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com 1 04 1:50 Scope of Work: Pedestal & Fiber Installation Traffic Control Plan: Emergency Night Hours Right Lane Closure 9/30/2023 by: Elite Traffic Solutions206.922.9205 Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ Plan Scale 1 : 600 (1'' = 50') (1) All spacing may be adjusted to accommodate interchange ramps,at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadwayconditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR ASPER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET LaneWidthFeet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570645 730 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. Renton KingP.167431 98057 www.invarion.com Imagery and map data ©2023, Google N 8TH ST25MPH PLATT ELECTRIC SUPPLY 801 HOUSER WAY N ROAD WORK AHEAD W20-1 ROAD WORKAHEAD W20-1 W4-2 RIGHT LANECLOSEDAHEAD W20-5 RIGHT LANECLOSEDAHEAD W20-5 X X X HOUSER WAY N30MPH X X 405 INTERSTATE NORTHBOUND 405 INTERSTATE SOUTHBOUND MATCHLINE SHEET 1Legend Cone X New Ped Pedestrian Detour Pole Sign Stand Traffic Light Work Area Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton King 2 04 1:50 P.167431 98057 Scope of Work: Pedestal & Fiber Installation 9/30/2023 by: Elite Traffic Solutions206.922.9205 Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ Plan Scale 1 : 600 (1'' = 50') (1) All spacing may be adjusted to accommodate interchange ramps,at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadwayconditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR ASPER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET LaneWidthFeet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570645 730 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. Traffic Control Plan: Emergency Night Hours Right Lane Closure www.invarion.com Imagery and map data ©2023, Google HH800 10' 7' 12' 40' N 8TH ST25MPH PLATT ELECTRIC SUPPLY801 HOUSER WAY N SIDEWALK CLOSED R9-9 DETOUR M4-9b DETOUR M4-9b DETOUR M4-9b DETOUR M4-9b ROADWORKAHEAD W20-1 RIGHT LANECLOSEDAHEAD W20-5 ROAD WORK AHEAD W20-1 P BE PREPAREDTO STOP W3-4 W20-7a BE PREPAREDTO STOP W3-4 W20-7a ONLY R3-5a R3-2 X LIGHT PLANT LIGHT PLANTSIDEWALK CLOSEDAHEAD CROSS HERE R9-11(R) SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(L) X X X X HOUSER WAY N30MPH X MATCHLINE SHEET 3 MATCHLINE SHEET 4 POLE 3 A0509543 POLE 4 A0509544 POLE 5 A0509545 LIGHT PLANT Legend Cone FlaggerHH 800 HH 800 Light Plant Pedestrian Detour Pole Traffic Light P UPO Work Area Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton King 3 04 1:50 P.167431 98057 Scope of Work: Handhole & Fiber Installation 9/30/2023 by: Elite Traffic Solutions206.922.9205 Julian Morales TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ Plan Scale 1 : 600 (1'' = 50') (1) All spacing may be adjusted to accommodate interchange ramps,at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadwayconditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR ASPER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET LaneWidth Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570645 730 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. Traffic Control Plan: Emergency Night Hours Right Lane Closure w/ UPO www.invarion.com Imagery and map data ©2023, Google ROAD WORK AHEAD W20-1 RIGHT LANECLOSED AHEAD W20-5 BE PREPARED TO STOP W3-4 ROADWORKAHEAD W20-1 BE PREPAREDTO STOP W3-4 X X X X X MATCHLINE SHEET 3 Legend Cone FlaggerHH 800 HH 800 Light Plant Pedestrian Detour Pole Traffic Light P UPO Work Area Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton King 4 04 1:50 P.167431 98057 Scope of Work: Handhole & Fiber Installation 9/30/2023 by: Elite Traffic Solutions206.922.9205 Julian Morales TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ Plan Scale 1 : 600 (1'' = 50') (1) All spacing may be adjusted to accommodate interchange ramps,at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadwayconditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR ASPER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET LaneWidth Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570645 730 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. Traffic Control Plan: Emergency Night Hours Right Lane Closure w/ UPO www.invarion.com REDLINE: ECO - 1379-1385 N 8th St, Renton, WA 98057 Job #: P.167431 WC: RNTNWA01 ADDRESS: 1379-1385 N 8th St, Renton, WA 98057 Mobile Claim ID: 74e4fecd-7b4c-4196-81de-d8cbedfeb12f Narrative: ECO due to the theft of a 1500PR and a 200PR copper cable along N 8th St. Approximately 4 spans of cable, around 650ft, will have to be replaced. The 1500PR cable can be downsized to a 900PR cable by removing 24 binder groups. 22 of those binder groups can be removed because they don't have workers in them. 2 of the binder groups to be removed have 1 worker that will need to be LST to a binder group that will remain. The theft spans from Pole #1 A0509541 to Pole #5 A0509545 (see figure 1). From Pole #1 the 1500PR cable goes from aerial to buried towards the west to MH-1149 with a splice atop of the pole. From Pole #5 the cable goes from aerial to buried to HH-800 with a splice atop the pole where the 200PR is spliced from the 1500PR and goes buried towards the building to the North and the 1500PR continues buried to the east. Scope of Work: - Cable will have to be replaced from Pole #1 to Pole #5. Downsizing the 1500PR to a 900PR copper cable. - At Pole #1 open sidewalk to expose the buried cable. Place a pedestal in the soft surface north of Pole #1. If there is not enough slack place a vault next to Pole #1. - At the pedestal splice the 1500PR to the 900PR consolidation. -Place 900PR copper cable going aerial along Pole #1 to Pole #5. - At Pole #5 open sidewalk to expose the buried cable. - At HH-800 place 2 splice cases. Splice the 900PR to the 1500PR and splice the 200PR to the north going towards the building. POLE #1 A0509541 POLE #4 A0509544 POLE #3 A0509543 POLE #2 A0509542 AERIAL 1500PR COPPER LINE MH-1149 HH-800 Figure 1: What was on the site before theft of cable POLE #5 A0509545 Buried 1500PR Copper Line Buried 200PR Copper Line Buried 1500PR Copper Line MFP23004975 RESTORATION PER CITY OF RENTON STANDARDS Figure 2: Scope of Work - What is to be placed as part of this job POLE #1 A0509541 POLE #5 A0509545 POLE #4 A0509544 POLE #3 A0509543 POLE #2 A0509542 AERIAL 900PR COPPER LINE Buried 1500PR Copper Line Buried 900PR Copper Line New Ped Splice Point #1 HH-800 Buried 900PR Copper Line Buried 1500PR Copper Line Buried 200PR Copper Line Splice Point #2