Loading...
HomeMy WebLinkAboutRS_Traffic Parking Report_New Life_230705_v1.pdf 12131 113th Avenue NE, Suite 203, Kirkland, WA 98034 | 425.821.3665 | MEMORANDUM Date: May 3, 2023 TG:1.22134.00 To: Alex Morganroth and Yong Qi – City of Renton From: Kassi Leingang, PE – Transpo Group cc: Kieth Kidwell – New Life Church Subject: New Life Church Office Addition - Traffic and Parking Summary The following memorandum summarizes the traffic and parking analysis completed for the proposed New Life Church Office Addition. The project description, trip generation, and parking analysis is provided. The estimated trip generation for the proposed development falls below the City’s traffic impact analysis 20 peak hour trip threshold; therefore, no additional analysis is required. Project Description New Life Church is an existing church located in Renton at 15711 152nd Avenue SE, south of the 154th Place SE/152nd Avenue SE/Maple Valley Road (State Route [SR] 169) intersection. The existing church is 129,000 square feet (sf), which includes the auditorium totaling 36,000 sf and the private school serving students Kindergarten through 8th grade totaling 38,680 sf. The proposal would construct a new 6,400 sf building to provide formal office space for the church staff to be located on the northern-most portion of the existing surface parking lot. This construction would eliminate approximately 40 parking stalls from the existing surface lot. No change to the existing congregation or school spaces are proposed with the addition. Access to the site would continue to be provided via 152nd Avenue SE. A site plan is included in Attachment A. Trip Generation The trip generation for the proposed addition was estimated based on Institute of Transportation Engineers (ITE) Trip Generation Manual (11th Edition, 2021). The land use assumed for the proposal was Office (Land Use #710). The estimated new trip generation for the proposed development is summarized in Table 1. The detailed trip generation estimate is included in Attachment B. Table 1. Estimated Weekday Project Trip Generation Daily Trips AM Peak Hour Trips PM Peak Hour Trips Land Use1 Size In Out Total In Out Total Office (LU #710) 6,400 sf 70 9 1 10 2 7 9 Note: sf = square feet 1. Trip generation estimates based on the number of units and the daily and peak hour trip rates from ITE Trip Generation Manual, 11th Edition (2021). As shown in the table, a 6,400-sf office is anticipated to generate a total of 70 new weekday daily trips with 10 occurring during the AM peak hour and 9 occurring during the PM peak hour. This is a conservative estimate for the new project trips as the addition is anticipated to accommodate existing staff such that trips are already occurring today and the proposed addition simply provides an improved working environment. The estimated weekday AM and PM peak hour trip generation for the addition per ITE falls below the City’s 20 peak hour trip threshold identified in the Traffic Impact Analysis Policy Guidelines for New Development and no additional traffic analysis is required for the proposed development. 2 Parking The site currently includes approximately 796 parking stalls. A parking analysis was conducted to verify with the proposed addition the Renton Municipal Code (RMC) parking requirements would be met. Parking requirements are identified in RMC 4-4-080,10.d. Since the overall site use is a church, the parking requirement for the proposed addition was reviewed per the description shown below for religious institutions. “A minimum and maximum of 1 for every 5 seats in the main auditorium; however, in no case shall there be less than 10 spaces…For all institutions making structural alterations or additions that do not increase the seating capacity of the auditorium, see “outdoor and indoor sports arenas, auditoriums, stadiums, movie theaters, and entertainment clubs.” The description of the “outdoor and indoor sports arenas, auditoriums, stadiums, movie theaters, and entertainment clubs” is shown below. “A minimum and maximum of 1 for every 4 fixed seats or 10 per 1,000 square feet of floor area of main auditorium or of principal place of assembly not containing fixed seats, whichever is greater.” The proposed addition is not assembly space and does not contain fixed seats; therefore, the addition was assumed to be consistent with office space. Additionally, as described above, the proposed project is located on the northern side of the site and would result in the elimination of 40 existing parking stalls, for a total of 756 total on-site parking stalls with the project. Table 2 provides the calculation of the required parking based on City code requirements considering the religious institution and proposed office addition as well as the parking supply with the development of the project. Table 2. Project Site Parking Code Requirements Land Use Size Minimum Parking Supply Rate1 Required Parking (Stalls) Parking Supply Church (Existing) 1,450 seats2 1 stall per 5 seats 290 796 stalls School (Existing) 780 student maximum enrollment 120 staff 1 stall per employee 120 Proposed Addition 6,400 sf 2 stalls per 1,000 sf 13 - 40 stalls Total Required Spaces 423 stalls - Total Parking Supply 756 stalls Notes: sf = square feet. 1. Renton Municipal Code 4-4-080. 10.d. 2. Main sanctuary with 1,200 seats + 250 secondary sanctuary. As shown in Table 2, based on City code, with the addition of the proposed project, a minimum parking supply of 423 parking stalls is required, which is well below the on-site parking supply of 756 stalls provided with completion of the project. Therefore, the parking code requirements are met with the proposed addition. Attachment A: Site Plan KIDS OFFICE(10'X8'6")CARE(9'9"X9')YOUTHPASTOR(10'X9')WORSHIPPASTOR(8'X10')I.T./STOR.JAN.SM CONF(13'6"X9')DIRECTOR(10'X8'6")FINANCESUITEHR/PAY(10'X8'6'')KIDS OFFICE(10'X8'6")KIDS OFFICE(10'X8'6")KIDSBREAKAREAGROUPPASTOR(8'X10')YOUTHWORSHIPFIRE SPRINK Δ152ND AVE SE6814 Greenwood Ave NSeattle, WA 98103T (206) 522-9510WWW.PACLAND.COMPRELIM INARY NOTFOR CONSTRUCT ION SCALE: 1" = 20'Know what'sbelow.before you dig.CallR Attachment B: Trip Generation Attachment B: Trip Generation Land Use Setting Size Units Model Equation Rate Units Inbound % Inbound Outbound Total 6,400 sf Daily General Urban/Suburban Rate -10.84 per ksf 50%35 35 70 AM Peak Hour General Urban/Suburban Rate -1.52 per ksf 88%9 1 10 PM Peak Hour General Urban/Suburban Rate -1.44 per ksf 17%2 7 9 1. Trip rates based on Institute of Transportation Engineers' (ITE) Trip Generation 11th Edition equation and average trip rate as shown above. Total Net New Notes: New Life Church Addition Proposed Use Church Office (LU 710) - WEEKDAY