Loading...
HomeMy WebLinkAboutMFP23001236.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP23001236 IVR Number: 23001236 Permit Information Permit Name: Puget Sound Energy Gas Permits Address/Location:03/07/2023Application Date:1823059079Parcel Number: 275 RAINIER AVE S Permit Type:08/29/2023Issue Date:Franchise Permit Work Class:08/28/2024Expiration Date:Major Utility Job Number: 109130700Franchise Type:Natural Gas Description: PSE Gas Install 1494' 6" PE Main in Joint Utility Trench. Install 120' 2" PE Main, & 30' 4" STW Main in ROW. 3 Service Replacements, 6 Service Test and Ties. Restoration per City of Renton standards Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031ApplicantX Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering INFRASOURCE, INC 6905 S 228TH ST KENT, WA 98032 PLEASE SEE ATTACHED 109130700 275 RAINIER AVE S Dustin Weller 206.379.4347 MFP23001236 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 8/29/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) CORRIE RYDBERG Corrie Rydberg Digitally signed by Corrie Rydberg Date: 2023.03.07 22:11:35 -08'00' 1113 11 11111111 1111 1111111111192313 11 11 11 11 RAIN IER AVE S 11111111 ONE WAY14 22S 3RD ST101012121111 10 12 12 RAINIER AVE SONE WAY ONE WAY RAINIER AVE SS 2ND ST (SR 900) 11111111 SW SUNSET BLVD ARRW-BRDRIGHT LANECLOSEDAHEADW20-5RW4-2RROADWORKAHEADW20-1350'350'350'350'ROADWORKAHEADW20-1 350'ROAD WORK AHEAD W20-1DETOURM4-9bDETOURM4-9bR9-11SIDEWALKCLOSEDAHEADR9-11SIDEWALK CLOSED AHEAD S/WCLOSEDR9-9X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1050 FEET OF WORK AREA ROADWORKAHEAD W20-1ROADWORKAHEADW20-1TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 1 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 75' NCL of S 3rd St & 74' WCL of Ranier Ave S, and 149' NCL of S 3rd St & 68' WCL of Ranier Ave S, and 181' NCL of S 3rd St & 48' WCL of Ranier Ave S. TRAFFIC FLOW SIGN LOCATION LEGEND TRENCH 28" TRAFFIC CONE CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1113 11 11111111 1111 1111111111192313 11 11 11 11 RAIN IER AVE S 11111111 ONE WAY14 22S 3RD ST101012121111 10 12 12 RAINIER AVE SONE WAY ONE WAYRAINIER AVE SS 2ND ST (SR 900) 11111111 SW SUNSET BLVD ARRW-BRD ARRW-BRDW20-7ABEPREPAREDTOSTOPW3-4350'350'RIGHT LANECLOSEDAHEADW20-5RW4-2RROADWORKAHEADW20-1350'350'350'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100' POLICEUPO W20-7AROADWORKAHEAD W20-1BEPREPARED TO STOP W3-4350'350'350'DETOURM4-9bDETOURM4-9bR9-11SIDEWALKCLOSEDAHEADR9-11SIDEWALK CLOSED AHEAD S/WCLOSEDR9-9S/WCLOSEDR9-9BUSINESS/ RESIDENT WILL BE INFORMED OF DRIVEWAY CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS.ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 350'350' ROAD WORK AHEAD W20-1BE PREPARE D TO STOP W3-4350'350'X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1750 FEET OF WORK AREA ROAD WORKAHEAD W20-1ROADWORKAHEADW20-1Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 2 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 218-365' SCL of S 2nd St & 39' WCL of Rainier Ave S. TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1113 11 11111111 1111 1111111111192313 11 11 11 11 RAIN IER AVE S 11111111 ONE WAY14 22S 3RD ST101012121111 10 12 12 RAINIER AVE SONE WAY ONE WAY RAINIER AVE SS 2ND ST (SR 900) 11111111 SW SUNSET BLVD M6-2 ARRW-BRD POLICEUPOW20-7ABEPREPAREDTOSTOPW3-4350'350'W4-2LLEFT LANECLOSEDAHEADW20-5LROADWORKAHEADW20-1350'350'350'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7ABEPREPAREDTOSTOPW3-4100'100'W4-2LLEFT LANECLOSEDAHEADW20-5LROADWORKAHEADW20-1100'100'100'W4-2LLEFT TWO LANES CLOSED AHEAD W20-5LROAD WORK AHEAD W20-1350'350'X' USE MAXIMUM AVAILABLE SPACE FOR SIGNS 350'ROADWORKAHEADW20-1X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1750 FEET OF WORK AREA ROADWORK AHEAD W20-1ROADWORKAHEADW20-1ARRW-BRD ARRW-BRD Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 3 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 218' SCL of S 2nd St & 11' WCL of Rainier Ave S, and 218' SCL of S 2nd St & 22' ECL of Rainier Ave S. TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1113 11 11111111 1111 1111111111192313 11 11 11 11 RAIN IER AVE S 11111111 ONE WAY14 22S 3RD ST101012121111 10 12 12 RAINIER AVE SONE WAY ONE WAY RAINIER AVE SS 2ND ST (SR 900) 11111111 SW SUNSET BLVD M6-2X' USE MAXIMUM AVAILABLE SPACE FOR SIGNS 350'ROADWORKAHEADW20-1 RIGHT LANE CLOSED AHEAD W20-5RW4-2RROAD WORK AHEAD W20-1350'350'ROADWORKAHEADW20-1350'ROADWORKAHEADW20-1DETOURM4-9bDETOUR M4-9bR9-11SIDEWALK CLOSED AHEADR9-11SIDEWALKCLOSEDAHEADS/WCLOSEDR9-9S/W CLOSED R9-9BUSINESS/ RESIDENT WILL BE INFORMED OF DRIVEWAY CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS.X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1050 FEET OF WORK AREA ROADWORKAHEAD W20-1ROADWORKAHEADW20-1Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 4 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 218' SCL of S 2nd St & 22-42' ECL of Rainier Ave S. TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40TRAFFIC FLOW SIGN LOCATION LEGEND TRENCH 28" TRAFFIC CONE CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1113 11 11111111 1111 1111111111192311 11 11 RAIN IER AVE S 11111111 ONE WAY S 3RD ST101012121111 10 12 12 RAINIER AVE SONE WAY ONE WAYRAINIER AVE SS 2ND ST (SR 900) 11 11 11 11 SW SUNSET BLVD ARRW-BRD ARRW-BRDW4-2RW20-5RRIGHTTWO LANESCLOSEDAHEADROADWORKAHEADW20-1350'350'350'W20-7ABEPREPAREDTOSTOPW3-4350'350'M6-2W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7ABEPREPAREDTOSTOPW3-4100'100'ROADWORKAHEADW20-1100'100'100'RIGHT LANECLOSEDAHEADW20-5RW4-2RW20-7AROADWORKAHEAD W20-1BEPREPARED TOSTOP W3-4350'350'350'DETOURM4-9bDETOURM4-9bR9-11SIDEWALKCLOSEDAHEADR9-11SIDEWALK CLOSED AHEAD S/WCLOSEDR9-9S/W CLOSEDR9-9BUSINESS/ RESIDENT WILL BE INFORMED OF DRIVEWAY CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS. POLICEUPO ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 350'350'X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1750 FEET OF WORK AREA ROADWORKAHEAD W20-1ROADWORKAHEADW20-1Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 5 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 218-101' SCL of S 2nd St & 39' WCL of Rainier Ave S. LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1113 11 11111111 1111 1111111111192311 11 11 RAIN IER AVE S 11111111 ONE WAY S 3RD ST101012121111 10 12 12 RAINIER AVE SONE WAY ONE WAY RAINIER AVE SS 2ND ST (SR 900) 11111111 SW SUNSET BLVD M6-2 W20-7ABEPREPAREDTOSTOPW3-4100'100'W4-2LLEFT LANECLOSEDAHEADW20-5LROADWORKAHEADW20-1100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100' ARRW-BRDW20-7ABEPREPAREDTOSTOPW3-4350'350'W4-2LLEFT LANECLOSEDAHEADW20-5LROADWORKAHEADW20-1350'350'350'W4-2LLEFT TWO LANES CLOSED AHEAD W20-5LROAD WORK AHEAD W20-1350'350' POLICEUPO ONLYR3-5RONLYR3-5RONLYR3-5RONLYR3-5RONLYR3-5RX'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1750 FEET OF WORK AREA ROAD WORKAHEAD W20-1ROADWORKAHEADW20-1350'W20-7ABE PREPARED TO STOP W3-4350'350'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 350'350' ARRW-BRD Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 6 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 92-101' SCL of S 2nd St & 11' WCL to 22' ECL of Rainier Ave S. LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1113 11 11111111 1111 1111111111192311 11 11 RAIN IER AVE S 11111111 ONE WAY S 3RD ST101012121111 10 12 12 RAINIER AVE SONE WAY ONE WAY RAINIER AVE SS 2ND ST (SR 900) 11111111 SW SUNSET BLVD M6-2 W20-7ABEPREPAREDTOSTOPW3-4100'100'W4-2LLEFT LANECLOSEDAHEADW20-5LROADWORKAHEADW20-1100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'350'350'ARRW-BRD POLICEUPO W20-7ABE PREPARED TO STOP W3-4350'350'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 350'350' RIGHT LA N E CLOSED AHEAD W20-5RW4-2RROAD WORK AHEAD W20-1350'350'350'DETOURM4-9bDETOUR M4-9bR9-11SIDEWALK CLOSED AHEADR9-11SIDEWALKCLOSEDAHEADS/WCLOSEDR9-9S/W CLOSED R9-9BUSINESS/ RESIDENT WILL BE INFORMED OF DRIVEWAY CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS.X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1750 FEET OF WORK AREA ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 7 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 101' SCL of S 2nd St & 44' ECL of Rainier Ave S, and 92' SCL of S 2nd St & 53' ECL of Rainier Ave S. LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1010121211 11 10 12 12 RAINIER AVE SONE WAY ONE WAY RAINIER AVE SS 2ND ST (SR 900) 11111111 ARRW-BRD POLICEUPO W20-7ABEPREPAREDTOSTOPW3-4100'100'W20-7ABEPREPAREDTOSTOPW3-4100'100'CENTER LANECLOSEDAHEADW9-3100'100'100'ROADWORKAHEADW20-1THRUTRAFFICMERGERIGHTW4-7RTHRUTRAFFICMERGELEFTW4-7L100'100'100'ROADWORKAHEADW20-1CENTER LANECLOSEDAHEADW9-3W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'350'350'W20-7AROAD WORK AHEAD W20-1BE PREPARED TO STOP W3-4350'350'350'LEAVE 5' MIN FOR PEDESTRIAN X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1050 FEET OF WORK AREA ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 8 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 48' ECL of Rainier Ave S & 11' SCL to 11' NCL of S 2nd St . LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1113 11 11111111 1111 1111111111192311 11 11 11111111 S 3RD ST101012121111 10 12 12RAINIER AVE SONE WAY ONE WAY RAINIER AVE SS 2ND ST (SR 900) 11111111 SW SUNSET BLVD RAIN IER AVE SW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'350'350'W20-7ABEPREPAREDTOSTOPW3-4100'100'RIGHT LANECLOSEDAHEADW20-5RW4-2RROADWORKAHEADW20-1100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100' POLICEUPO ARRW-BRD S/W CLOSED R9-9W20-7ABE PREPARED TO STOP W3-4350'350'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 350'350' RIGHT LAN E CLOSED AHEAD W20-5RW4-2RROAD WORK AHEAD W20-1350'350'350' DETOUR M4-9bR9-11SIDEWALK CLOSED AHEAD DETOURM4-9bR9-11SIDEWALKCLOSEDAHEADPLACE PDETOUR SIGNS AT CROSSWALK INTERSECTION SOUTH/EAST OF AIRPORT WAY S & RAINIER AVE S.S/WCLOSEDR9-9X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1750 FEET OF WORK AREA ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 9 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 48' ECL of Rainier Ave S & 68' NCL of S 2nd St, and 39' ECL of Rainier Ave S & 77' NCL of S 2nd St. LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1113 11 11111111 1111 1111111111192311 11 11 11111111 S 3RD ST101012121111 10 12 12 RAINIER AVE SONE WAY ONE WAY RAINIER AVE SS 2ND ST (SR 900) 11111111 SW SUNSET BLVD RAIN IER AVE SW20-7ABEPREPAREDTOSTOPW3-4100'100'W4-2LLEFT TWO LAN E S CLOSED AHEAD W20-5LROAD WORK AHEAD W20-1350'ONLYR3-5RONLYR3-5RONLYR3-5RONLYR3-5RONLYR3-5RX'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1750 FEET OF WORK AREA ROADWORKAHEAD W20-1ROADWORKAHEADW20-1W20-7ABE PREPARE D TO STOP W3-4350'350'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 350'350' ARRW-BRDARRW-BRDW20-7ABEPREPAREDTOSTOPW3-4350'350'W4-2LLEFT LANECLOSEDAHEADW20-5LROADWORKAHEADW20-1350'350'350'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100' POLICEUPO M6-2W4-2LLEFT LANECLOSEDAHEADW20-5LROADWORKAHEADW20-1100'100'100' Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 10 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 77' NCL of S 2nd St & 11' ECL to 22' WCL of .Rainier Ave S. LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1010121211 11 10 12 12 ONE WAY ONE WAY RAINIER AVE SRAINIER AVE SH A Y E S P L S W 18 11 12 11 11 121010 SW VICTORIA ST 1212RAINIER AVE SBUSSTOPS 2ND ST (SR 900) 11111111 POLICEUPO ARRW-BRD ARRW-BRD W20-7AROAD WORK AHEAD W20-1BEPREPARED TOSTOP W3-4100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4100'100'100'W20-7ABEPREPAREDTOSTOPW3-4350'350'RIGHT LANECLOSEDAHEADW20-5RW4-2RROADWORKAHEADW20-1350'350'350'ROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4 100'100'ROADWORKAHEADW2 0 - 1 BEPREPAREDTOSTOPW3 - 4 1 0 0 ' 1 0 0 ' DETOURM4-9bR9-11SIDEWALK CLOSED AHEAD PLACE PDETOUR SIGNS AT CROSSWALK/ INTERSECTION NORTH/WEST OF SW SUNSET BLVD & RAINIER AVE S.DETOURM4-9bR9-11SIDEWALKCLOSEDAHEADS/WCLOSEDR9-9PLACE PDETOUR SIGNS AT CROSSWALK INTERSECTION SOUTH/WEST OF AIRPORT WAY S & RAINIER AVE S.X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1750 FEET OF WORK AREA ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1S/WCLOSEDR9-9Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 11 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 32' NCL of S 2nd St & 23' WCL of Rainier Ave S, and 173' NCL of S 2nd St & 43' WCL of Rainier Ave S. LEGEND TRENCH 28" TRAFFIC CONE TRAFFIC FLOW SIGN LOCATION FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1010121211 11 10 12 12 RAINIER AVE SONE WAY ONE WAYRAINIER AVE SH A Y E S P L S W S TOBIN STRAINIER AVE S191918 11 12 11 11 12 1010c-curbSW VICTORIA ST 1212RAINIER AVE SBUSSTOPS 2ND ST (SR 900) 11111111ARRW-BRDROADWORKAHEADW20-1100' ROADWORKAHEAD W20-1350'RIGHT LANECLOSEDAHEADW20-5RW4-2RROADWORKAHEADW20-1350'350'350'ROADWORKAHEADW20-1 100'ROADWORKAHEADW2 0 - 1 1 0 0 'DETOURM4-9bR9-11SIDEWALKCLOSEDAHEADPLACE PDETOUR SIGNS AT CROSSWALK INTERSECTION SOUTH/WEST OF AIRPORT WAY S & RAINIER AVE S. DETOURM4-9bR9-11SIDEWALK CLOSED AHEAD ROADWORKAHEADW20-1100'S/WCLOSEDR9-9X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1050 FEET OF WORK AREA ROADWORKAHEAD W20-1ROADWORKAHEADW20-1BUSINESS/ RESIDENT WILL BE INFORMED OF DRIVEWAY CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS. Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 12 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 173' NCL of S 2nd St & 43' WCL of Rainier Ave S, and 262' SCL of SW Victoria St & 43' WCL of Rainier Ave S. TRAFFIC FLOW SIGN LOCATION LEGEND TRENCH 28" TRAFFIC CONE CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1010121211 11 10 12 12 RAINIER AVE SONE WAY ONE WAY H A Y E S P L S W S TOBIN ST1919 18 11 12 11 11 12BUSSTOP 1010SW VICTORIA ST 1212RAINIER AVE SBUSSTOPS 2ND ST (SR 900) 11111111 ARRW-BRD ARRW-BRD DETOURM4-9bR9-11SIDEWALK CLOSED AHEAD S/W CLOSEDR9-9S/WCLOSEDR9-9W4-2RW20-5RRIGHTTWO LANESCLOSEDAHEADROADWORKAHEADW20-1350'350'350'350'ROAD WORKAHEAD W20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1 100'ROADWORKAHEADW2 0 - 1 1 0 0 'ROADWORKAHEADW20-1100'X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1050 FEET OF WORK AREA ROADWORKAHEAD W20-1ROADWORKAHEADW20-1BUSINESS/ RESIDENT WILL BE INFORMED OF DRIVEWAY CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS. Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 13 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 173' NCL of S 2nd St & 43' WCL of Rainier Ave S, and 262-208-126' SCL of SW Victoria St & 43' WCL of Rainier Ave S, and 208' SCL of SW Victoria St & 11' WCL of Rainier Ave S. TRAFFIC FLOW SIGN LOCATION LEGEND TRENCH 28" TRAFFIC CONE CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1010121211 11 10 12 12 ONE WAY ONE WAYRAINIER AVE SH A Y E S P L S W S TOBIN ST1919 18 11 12 11 11 12 1010 SW VICTORIA ST 1212RAINIER AVE SBUSSTOPS 2ND ST (SR 900) 11111111 ARRW-BRD W4-2LLEFT LANECLOSEDAHEAD W20-5LROADWORKAHEAD W20-1350'350'350'W4-2LLEFT LANECLOSEDAHEADW20-5LROADWORKAHEADW20-1350'350'350'100'ROADWORKAHEADW20-1ROADWORKAHEADW20-1 100'ROADWORKAHEADW2 0 - 1 1 0 0 'ROADWORKAHEADW20-1Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 14 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 208' SCL of SW Victoria St & 11' WCL to 11' ECL of Rainier Ave S. TRAFFIC FLOW SIGN LOCATION LEGEND TRENCH 28" TRAFFIC CONE CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 1010121211 11 10 12 12 RAINIER AVE SONE WAY ONE WAYRAINIER AVE SH A Y E S P L S W 18 11 12 11 11 12BUSSTOP 1010 SW VICTORIA ST 1212RAINIER AVE SBUSSTOPS 2ND ST (SR 900) 11111111 ARRW-BRD ARRW-BRD W4-2RW20-5RRIGHTTWO LANESCLOSEDAHEAD ROAD WORKAHEAD W20-1350'350'350'ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1 100'ROADWORKAHEADW2 0 - 1 1 0 0 'ROADWORKAHEADW20-1350'DETOUR M4-9bR9-11SIDEWALK CLOSED AHEAD S/W CLOSED R9-9S/WCLOSEDR9-9DETOURM4-9bR9-11SIDEWALKCLOSEDAHEADPLACE PDETOUR SIGNS AT CROSSWALK INTERSECTION SOUTH/EAST OF AIRPORT WAY S & RAINIER AVE S.X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1050 FEET OF WORK AREA ROAD WORKAHEAD W20-1ROADWORKAHEADW20-1BUSINESS/ RESIDENT WILL BE INFORMED OF DRIVEWAY CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS. Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 15 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 208' SCL of SW Victoria St & 11-45' ECL of Rainier Ave S, and 58' SCL to 12 NCL of SW Victoria St & 21' ECL of Rainier Ave S. TRAFFIC FLOW SIGN LOCATION LEGEND TRENCH 28" TRAFFIC CONE CHEVRON ARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notification # 11425277 MFP23001236 RAINIER AVE SH A Y E S P L S W S TOBIN STRAINIER AVE S191918 11 12 11 11 12 14 11 12 12 11 12 11 12 BUSSTOP1010c-curb1212RAINIER AVE SBUSSTOPHARDIE AVE SWSW VICTORI A S T 10101010 1010 STREETCLOSEDBARRICADE R11-2ONLY R3-5L ONLY R3-5L ONLYR3-5RONLYR3-5RARRW-BRDRIGHT LANECLOSEDAHEADW20-5RW4-2RROADWORKAHEADW20-1350'350'350'350'ROAD WORKAHEAD W20-1ROADWORKAHEADW2 0 - 1 1 0 0 'ROADWORKAHEADW20-1100'DETOURAHEADW20-2ROADCLOSEDAHEADW20-3 100'100'ROADWORKAHEADW20-1 100'DETOUR AHEAD W20-2ROAD CLOSED AHEAD W20-3100'100'ROAD WORK AHEAD W20-1100'DETOURAHEADW20-2ROADCLOSEDAHEADW20-3100'100'ROADWORKAHEADW20-1100'RESIDENT(S) WILL BE INFORMED BY CUSTOMER OUTREACH OF ROAD CLOSURE 10 DAYS IN ADVANCE. CREW CAN MOVE (SHIFT) CONES AND EQUIPMENT IN THE EVENT OF EMERGENCY VEHICLE ACCESS. FOR DETOUR MAP SEE SHEET 17 MOVE BUS STOP 150' NORTH.DETOURM4-9bR9-11SIDEWALKCLOSEDAHEADPLACE PDETOUR SIGNS AT CROSSWALK INTERSECTION SOUTH/WEST OF AIRPORT WAY S & RAINIER AVE S. DETOUR M4-9bR9-11SIDEWALK CLOSED AHEAD PLACE PDETOUR SIGNS AT CROSSWALK/ INTERSECTION NORTH/ WEST OF S 2nd St & Rainier Ave S. S/WCLOSEDR9-9S/WCLOSEDR9-9DETOURX'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1050 FEET OF WORK AREA ROAD WORKAHEAD W20-1ROADWORKAHEADW20-1Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 16 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TRAFFIC FLOW SIGN LOCATION LEGEND TRENCH 28" TRAFFIC CONE CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 173' NCL of S 2nd St & 43' WCL of Rainier Ave S, and 262-208-126' SCL of SW Victoria St & 43' WCL of Rainier Ave S, and 208' SCL of SW Victoria St & 45' WCL of Rainier Ave S. Notification # 11425277 MFP23001236 STREETCLOSEDBARRICADE R11-2DETOURDETOUR M4-9DETOURM4-9R007-LR007-RDET OU R M4-9DETO U R M9-4RD E TO U R M4-9 D E TOUR M9-4 R DETOURM4-9DETOURM4-9DETOURM4-9DETOURM4-9LDETOURM4-9 DETOURM4-9L DETOUR M4-9DETOUR M4-9Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 17 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN DETOUR MAP N Notification # 11425277 MFP23001236 RAINIER AVE SRAINIER AVE SH A Y E S P L S W S TOBIN STRAINIER AVE S191918 11 12 11 11 12 14 11 12 12 11 12 11 12 BUSSTOP1010c-curbSW VICTORIA ST1212 RAINIER AVE SBUSSTOPHARDIE AVE SWSW VICTORI A S T 10101010 1010 ARRW-BRD R007-RDETOURM4-9R007-LDETOUR M4-9RIGHT LANECLOSEDAHEADW20-5RW4-2RROADWORKAHEADW20-1350'350'350'ROAD WORK AHEAD W20-1350'ROADWORKAHEADW20-1 ROADWORKAHEADW2 0 - 1 ROADWORKAHEADW20-1FOR DETOUR MAP SEE SHEET 19 X'X'PLACE W20-1 SIGNS ON ALL ADJACENT PUBLIC STREETS WHERE TRAFFIC COULD ENTER WORK AREA WITHIN 1050 FEET OF WORK AREA ROADWORKAHEAD W20-1ROADWORKAHEADW20-1MOVE BUS STOP 150' NORTH. Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 18 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 TRAFFIC FLOW SIGN LOCATION LEGEND TRENCH 28" TRAFFIC CONE CHEVRONARROW BOARD WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between ____. and ____. unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 8. Work area will be 173' NCL of S 2nd St & 43' WCL of Rainier Ave S, and 5' NCL of SW Victoria St & 58' WCL of Rainier Ave S. Notification # 11425277 MFP23001236 STREETCLOSEDBARRICADER11-2R007-RDETOURM4-9R007-LDETOUR M4-9DETOUR M4-9DETOUR M4-9LDETOURM4-9DETOURM4-9LDETOURM4 - 9 DETOURM4-9DETOURM4-9DETOURM4-9DETOURM9-4RDETOURM4-9DETOURM9-4RDETOUR M4-9DETOU R M4-9Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 19 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN DETOUR MAP N Notification # 11425277 MFP23001236 RAINIER AVE SRENTON AVE EXT.S TOBIN ST191912 1411121211121112BUS STOP c-curbHAYES PL SWHARDIE AVE NWBUSSTOP RAINIER AVE S1111121211111111 11 12 12 12 12 181111121111111514 AIRPORT WAY S1111111111 C-CURBC-CURB121211111212161212LAKE AVE S111112121111111111171711 W20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'350'350'POLICEUPOPOLICEUPO W20-7ABEPREPAREDTO STOP W3-4350'350'W20-7ABEPREPAREDTOSTOP W3-4 350'350'W20-7ABEPREPAREDTOSTOPW3-4 350'350' ARRW-BRD W4-2R W20-5RRIGHTTWO LANESCLOSEDAHEADROADWORKAHEADW20-1 350'350'350'RIGHT LANECLOSEDAHEADW20-5R W4-2RROADWORKAHEADW20-1 350'350'350'X'X'PLACE W20-1 SIGNS ON ALLADJACENT PUBLIC STREETSWHERE TRAFFIC COULD ENTERWORK AREA WITHIN1750 FEET OF WORK AREAROADWORKAHEADW20-1 ROADWORKAHEADW20-1ARRW-BRD KEEP R4-7B RIGHT W20-1ROAD WORK AHEAD LEFT LANE CLOSEDAHEAD W20-5LW4-2L350'≥350'≥350'≥ARRW-BRD KEEPR4-7BRIGHTTEMPORARY TRAFFIC CONTROL PLANNSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVSafaa Al Neema(425) 398-6077safaa.alneema@pse.com20 OF 21275 Rainier Ave S, Renton, WA 980571 10913070010/24/2023Puget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. 012611Card Exp. 10/31/2024Safaa.alneema@pse.com(425)398-6077LEGENDTRENCH28" TRAFFIC CONETRAFFIC FLOWSIGN LOCATIONFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYNotification # 11425277Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between ____. and ____.unless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.8. Work area will be 30' SCL of Airport Way S &133-163' WCL of Rainier Ave S.MFP23001236 S 2ND ST (SR 900) 2121LAKE AVE SLAKE AVE SLAKE AVE S2222 1212 1919W4-119W20-1ROADWORKAHEAD100'≥100'≥100'≥W1-4LRIGHTSHOULDERCLOSEDW21-5aRW20-1ROAD WORK AHEAD100'≥maintain 11' laneS TOBIN ST S TOBIN ST S 2ND ST (SR 900) PLACE SIGNS BOTH SIDES OF WORK AREA FROMTOTOW AWAY AREAPHONE 888-9999INFRASOU RCE LLC 0 00 0 000 000 NO PARKINGNO-PAR K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Safaa Al Neema (425) 398-6077 safaa.alneema@pse.com 21 OF 21275 Rainier Ave S, Renton, WA 98057 1 109130700 10/24/2023 Puget Sound Energy Traffic Control Supervisor:Safaa Al Neema Card No. 012611 Card Exp. 10/31/2024 Safaa.alneema@pse.com (425)398-6077 TEMPORARY TRAFFIC CONTROL PLAN N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT Notification # 11425277 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, Night time work to take place between _____________and ______________.) MFP23001236 ROPE PROPOSED PIPE 2" MPE IP MAIN WORK AREA SAP BATCH YEAR & FOOTAGE ACTUAL LENGTH OF RETIREMENT MATERIAL RETIRED ORIGINAL JOB ORIGINAL YEAR PROPOSED LENGTH OF RETIREMENT SIZE OF RETIRED MAIN N N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A GAS PROJECT PHASE Notification #Order # SVC Retirement Relocate SAP Superior Service/Meter Service/Meter Dis. Reg. / FT Ind. MSA Ind. Service Service/Meter GAS MAIN INSTALLATION/RETIREMENT Type/Work ManufacturerPipe Size Type Est Length Act Lgth INSTALL N/AMN Retirement N/A N/AN/A N/A 11425277 N/A 109130700 108642050 N/A 109148384 Service/Meter RETIRMENT 2"STW 108621671 VICINITY MAP STANDARD GAS CONSTRUCTION NOTES: 1.FIELD LOCATE ALL UNDERGROUND UTILITIES. EXCAVATOR TO CALL "ONE-CALL" TWO WORKING DAYS PRIOR TO CONSTRUCTION, IN WESTERN WASHINGTON CALL: 1-800-424-5555. OR CALL NATIONWIDE: 811 2.NOTIFY APPROPRIATE PERMITTING AGENCY PRIOR TO JOB START (SEE PERMIT REQUIREMENTS). 3.ALL CONSTRUCTION IS TO CONFORM TO PSE GAS OPERATING STANDARDS AND GAS FIELD PROCEDURES. 4.EROSION AND SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION AND SEDIMENT CONTROL AND ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. 5.NOTIFY PROPERTY OWNERS ADJACENT TO PROPOSED CONSTRUCTION ACTIVITIES A MINIMUM OF TWO WORKING DAYS PRIOR TO BEGINNING CONSTRUCTION. USE iSi TO DISTRIBUTE FLYERS IF JOB IS LARGE, OTHERWISE HAND DELIVER FLYERS BE SURE TO INCLUDE THE LIST OF FREQUENTLY ASKED QUESTIONS AND INFORMATION ABOUT THE OPPORTUNITY TO PURCHASE AN EXCESS FLOW VALVE WHEN THEIR SERVICE IS INSTALLED OR REPLACED PER GAS OPERATING STANDARD 2550.1600. ALLOW ADEQUATE TIME FOR CUSTOMER DECISION AND RESPONSE. 6.ANY CHANGE IN ROUTE, PIPE SIZE/TYPE, TIE-IN METHOD OR ADDITIONAL MAIN FOOTAGE MUST BE APPROVED BY THE APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 7.COMPLETE "PIPE CONDITION REPORT" ON ALL METALLIC PSE FACILITIES. CHECK BOX ON REPORT FOR WIRE BOX (TEST LEAD) INSTALLATION. 8.PIPELINE MARKERS AND WARNING SIGNS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2500. 9.INSTALL MAIN VALVES OUT OF TRAFFIC WHERE POSSIBLE. VALVE MARKERS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2600 FOR ALL HP VALVES IF THE LOCATION IS NOT READILY ACCESSIBLE, AND FOR ALL VALVES WHERE PERSISTENT SNOWFALL MAY OBSCURE THE VALVE BOX. 10.TO PREVENT ACCIDENTAL OVERPRESSURE OF ADJOINING SYSTEMS, NO TWO MAINS SHALL BE CONNECTED EXCEPT AS SHOWN ON THIS DESIGN UNLESS APPROVED BY APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 11.SYSTEM MAOP DENOTED BY: SYSTEM MAOP = _45_ PSIG 12.GAUGE AND MONITOR USE OF ALL STOPPERS TO ENSURE ADEQUATE FEED. 13.RESTORE ALL DRIVEWAYS SUBJECT TO OPEN CUT TO ORIGINAL OR BETTER CONDITION. 14.PURGE POINTS TO BE INSTALLED PER PSE GAS OPERATING STANDARDS 2525.3400. 15.MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400. 16.IF METALLIC PIPE IS INVOLVED, COORDINATE INSTALLATION WITH CP TECH. ___________________________, PHONE______________. 17.NOTE ALL ACTUAL FOOTAGE, LOCATION AND MATERIAL CHANGES ON THE AS-BUILT IN RED. ( ') DENOTES FOOTAGE BETWEEN FITTINGS. 18.EXCESS FLOW VALVE TO BE INSTALLED ON ALL NEW RESIDENTIAL SERVICES PER GOS 2500.2200. (RECORD ALL INFORMATION ON D-4 CARD) STANDARD IP & LP GAS REPLACEMENT CONSTRUCTION NOTES 1.NOTIFY GAS CUSTOMERS, OR DISTRIBUTE FLYER #1443 A MINIMUM OF TWO WORKING DAYS PRIOR TO A PLANNED OUTAGE. 2.INSTALL ONE POUND ANODE FOR EVERY 1000' OF LOCATING WIRE. INSTALL ANODE AND TEST LEAD WIRES PER PSE GAS OPERATING STANDARD 2525.2300. 3.MAINTAIN CATHODIC PROTECTION FOR STEEL MAINS BY THE USE OF CONTINUITY BONDS OR OTHER MEANS DETERMINED BY THE PSE CORROSION ENGINEER PER PSE GAS OPERATING STANDARD 2600.1300. 4.INSTALL ANODES AND TEST LEAD WIRES AS REQUIRED PER PSE GAS FIELD PROCEDURES 4515.1000 AND 4515.1020 AND PSE GAS OPERATING STANDARD 2600.1200. TEST LEAD WIRES ARE REQUIRED ON ALL TRANSITION FITTINGS. 5.INSTALL CURB VALVE AT PROPERTY LINE OR 5/8" PE WHIP AT MAIN (AS REQUIRED) ON NEW AND EXISTING SERVICES PER PSE GAS OPERATING STANDARD 2550.1600. 6.REFER TO PSE GAS OPERATING STANDARD 2525.1700 FOR MAIN AND SERVICE COVER REQUIREMENTS. 7.MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300, 2525.3400 AND 2525.1200, AND PSE GAS FIELD PROCEDURE 4700.1500. 8.PROJECT MANAGER TO MAKE EGOR RUN IMMEDIATELY PRIOR TO STARTING CONSTRUCTION. 9.INSTALL REPLACEMENT MAINS PER PSE GAS OPERATING STANDARDS 2525.2100 FOR INSERTIONS AND 2525.3600 FOR ABANDONMENT OR DEACTIVATION. 10.PLUG ENDS OF DEACTIVATED OR INSERTED MAINS AND SERVICES IN ACCORDANCE WITH PSE GAS OPERATING STANDARDS 2525.2100 AND 2525.3600. 11.REMOVE OR RENDER INOPERABLE DEACTIVATED VALVES ON CASING WHERE MPE PIPE IS INSERTED. 12.INSIDE METER SETS SHALL BE MOVED OUTSIDE WHENEVER POSSIBLE OR SET REGULATORS AND VENTS OUTSIDE PER PSE GAS OPERATING STANDARDS 2575.2300 AND 2550.1700. 13.REPLACE EXISTING ACTIVE SERVICES PER PSE GAS OPERATING STANDARDS 2525.2100 AND 2575.2300. 14.REPLACE ALL "NO RECORD" SERVICES AND 1-1/8" PE SERVICES INSTALLED PRIOR TO 1985. 15.ACTIVE SERVICES TO BE REPLACED DENOTED BY: 16.ACTIVE SERVICES TO BE PARTIALLY REPLACED AND TEST & TIED DENOTED BY: 17.ACTIVE SERVICES TO BE TESTED & TIED DENOTED BY: N/A 109130700 N/A AS NOTED 1/7 KING N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr RENTON 058J CSPSKGPI 208.080 208.080/208.081 209.080/209.081 "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 206.379.4347 dustin.weller@pse.com DUSTIN WELLER RAINIER AVE S - PHASE 4 1425' 6"PE 1494' #### #### ##### PUBLIC IMPROVEMENT 275 RAINIER AVE S, RENTON, WA 98057 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)1091307004"STW 30' 4"STW 30' 2"PE 120' SW 18-23-05 C.HAWLEY 206.809.4434 206.379.4347D.WELLER C.HAWLEY 206.809.4434 12/13/2022 12/13/2022 12/13/2022 S.ALNEEMA 253.234.6447 05/11/2023 W.JOHNSON 206.716.2730 05/15/2023 206.379.4347D.WELLER 06/05/2023 RAINIER AVE S - PHASE 4 Owner / Developer Contact Info officeATTN: PSE N/A N/A PSE N/A HOLE HOG TABLE CALLOUT LOCATION DEPTH LENGTH BP1 START BP2 END BP3 START BP4 END BP5 START BP6 END BP7 START BP8 END BP9 START BP10 END BP11 START BP12 END BP13 START BP14 END BP15 START BP16 END BP17 START BP18 END BP19 START BP20 END Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 COORDINATE INSTALLATION WITH GAS SYSTEMS INTEGRITY (GSI) 05/25/2023: PER G.VUKOSAV, REPLACE 4" MAIN WITH 4" MAIN IN AIRPORT WAY. REPLACE 2" MAIN WITH 6" MAIN IN RAINIER AVE S. COMPLETE THE LOOP CONNECTING EX. 6" MPE MAIN 1090047020 AND 6" MPE MAIN (TO REPLACE EX. 2" STW MAIN 71E109) IN S RAINIER AVE PER 500'RULE. IT IS SUFFICIENT TO INSTALL 2" MAIN TO SERVE CUSTOMER ADDRESS #104 IN RAINIER AVE S. IT IS SUFFICIENT TO INSTALL 2" MAIN TO SERVE CUSTOMER ADDRESS #225 IN RAINIER AVE S. IT IS SUFFICIENT TO USE 6"X2" HV TEE IN PLACE OF 6" INLINE TEE FOR TIE-IN PROPOSED 2" MPE MAIN TO 6" MPE MAIN IN SW VICTORIA ST & S 2ND ST. PLEASE USE FULL OPENING 4" B/O FITTINGS FOR TIE-INS IN AIRPORT WAY. SYSTEM:IP-058 MAOP: 45# PROJECT IS WITHIN EMERGENCY SECTION 058J (NO NEW ISOLATION VALVES ARE REQUIRED). PIPE: N-355102396_3 BYPASS NOTES, TIE-IN DETAIL 1, SHEET 6: THE EX. 6" PE MAIN 9415836 ALONG SW VICTORIA ST IS 2 WAYS FEED IN THE SEGMENT BETWEEN HARDIE AVE SW AND RAINIER AVE S. THE SEGMENT OF THE EX. 6" PE MAIN ON SW VICTORIA ST (BETWEEN HARDIE AVE SW AND RAINIER AVE S) CAN BE TAKEN OUT OF SERVICE ON 25F DAY AND ABOVE WITHOUT INSTALLING A BY-PASS. GAUGE BOTH SIDES OF THE SQUEEZE PER PSE STANDARDS ON THE EX. 6" PE IP MAIN IN SW VICTORIA ST. IF THE PRESSURES DO NOT STABILIZE AT 37# (WEST SIDE GAUGE) AND 39# (EAST SIDE GAUGE), RELEASE THE SQUEEZE AND CALL GSI-SP FOR FURTHER INSTRUCTIONS. (EXPECTED DROP OF THE PRESSURE ON THE WEST SIDE (GAUGE) IS 2-3#) NOTE: ***WHEN THE SCHEDULE DATE IS KNOWN, PLEASE CONTACT GSI-SP FOR A CURRENT SYSTEM REVIEW TO DETERMINE IF TODAY'S REVIEW COMMENTS ARE STILL VALID AND TO CHECK THE OUT OF SERVICE SPREADSHEET TO VERIFY NO OTHER MAINS ARE OUT OF SERVICE IN THE AREA *** SYSTEM:IP-058 MAOP: 45# PROJECT IS WITHIN EMERGENCY SECTION 058J (NO NEW ISOLATION VALVES ARE REQUIRED). PIPE:N-106942858_2 COORDINATE INSTALLATION WITH CORROSION CONTROL (CP) 6/21/2018: PER W.JOHNSON, MAKE SURE THAT ALL T/L BOX'S AND VALVE BOXES ARE ACCESIBLE. IF THE STW GAS MAIN HAS TO BE DUG UP INSTALL 20# ANODE. 5/15/2023: PER W.JOHNSON (VIA EMAIL), THE CPA TASKS ARE GOOD COORDINATE INSTALLATION WITH PRESSURE CONTROL (PC) PENDING APPROVAL... MFP23001236 This permit is for Major construction work in the ROW and will be billed at an additional $158/HR for inspections. After hours and weekend work will be billed at $175/HR THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 206.379.4347 dustin.weller@pse.com DUSTIN WELLER ROPE PROPOSED PIPE 2" MPE IP MAIN N/A 109130700 N/A 1"=75'2/7 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr RENTON Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 SW VICTORIA ST S 2ND ST SW SUNSET BLVD S 3RD STRAINIER AVE S109130700SITE PLAN A SCALE: 1'=75' SITE PLAN B SCALE: 1'=75'RAINIER AVE NAIRPORT WAY HARDIE AVE NWREN T O N A V E E X T E N SI O NHARDIE AVE NWNELSON PL NWS TOBIN STLAVE AVE SRAINIER AVE SHARDIE AVE SWHARDIE AVE SWHAY ES P L SW HARDIE A VE SWRAINIER AVE SKING COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP 058J CSPSKGPI 208.080 208.080/208.081 209.080/209.081SW 18-23-05 C.HAWLEY 206.809.4434 206.379.4347D.WELLER C.HAWLEY 206.809.4434 12/13/2022 12/13/2022 12/13/2022 S.ALNEEMA 253.234.6447 05/11/2023 PLOT PLAN A SEE PAGE 3 PLOT PLAN B SEE PAGE 4 PLOT PLAN C SEE PAGE 5 PLOT PLAN D SEE PAGE 6 PLOT PLAN E SEE PAGE 7 W.JOHNSON 206.716.2730 05/15/2023 206.379.4347D.WELLER 06/05/2023 PUBLIC IMPROVEMENT 275 RAINIER AVE S, RENTON, WA 98057 RAINIER AVE S - PHASE 4 MFP23001236 RAINIER AVE SSW SUNSET BLVD S 3RD ST 250 RAINIER AVE SIP GAS FL O W IP GAS FL O WIP GAS FLOWIP GAS FLOW IP GAS FLOW Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 206.379.4347 dustin.weller@pse.com DUSTIN WELLER ROPE PROPOSED PIPE 2" MPE IP MAIN N/A N/A 1"=20'3/7 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr 109130700 RENTON EXISTING FIRE HYDRANT SHOWN FOR REFERENCE 135'N C/L & 65'W C/L BEGIN JOINT TRENCH & ELBOW 6"X45° MPE 181'N C/L & 48'W C/L ____'N C/L & ____'W C/L PROPOSED PIPE 6" MPE IP MAIN 46'W C/L, ____'W C/L PLOT PLAN A SCALE: 1" = 20'-0" EXISTING END OF MAIN CAP 6" MPE 94'N C/L & 66'W C/L ____'N C/L & ____'W C/L SQUEEZE & FUSE TIE-IN & ELBOW 6"X45° MPE 75'N C/L & 74'W C/L ___'N C/L & ___'W C/L CUT & CAP CAP 6" MPE 77'N C/L & 72'W C/L ____'N C/L & ____'W C/L TEE SVC 1/2"X5/8" PE OUTLET (GAUGE TEE) ____'N C/L & ____'W C/L PROPOSED PIPE 6" MPE IP MAIN 71'W C/L, ___'W C/L Scale: NTS TIE IN DETAIL1 3 1 3 109130700KING COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP 058J CSPSKGPI 208.080 208.080/208.081 209.080/209.081SW 18-23-05 ELBOW 6"X45° MPE 149'N C/L & 68'W C/L ____'N C/L & ____'W C/L C.HAWLEY 206.809.4434 206.379.4347D.WELLER C.HAWLEY 206.809.4434 12/13/2022 12/13/2022 12/13/2022 S.ALNEEMA 253.234.6447 05/11/2023 W.JOHNSON 206.716.2730 05/15/2023 206.379.4347D.WELLER 06/05/2023 PUBLIC IMPROVEMENT 275 RAINIER AVE S, RENTON, WA 98057 RAINIER AVE S - PHASE 4 6" ELECTROFUSION COUPLING (3' FROM ELBOW) 75'N C/L & 74'W C/L ___'N C/L & ___'W C/L 6" ELECTROFUSION COUPLING 83'N C/L & 71'W C/L ___'N C/L & ___'W C/L 6"X1-1/8" MPE TEE (PURGE) ___'N C/L & ___'W C/L 6" POLYVALVE 79'N C/L & 71'W C/L ___'N C/L & ___'W C/L STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5GASSED UP PIPELINE PIPE SEGMENT FOREMAN'S DATENAME 45 IP058- 45 MFP23001236 RAINIER AVE S265261END OF JOB# 0878-1958 START OF JOB# 71E109-1971 IP GAS FLOWIP GAS FLOWPROPOSED 1-1/4" PE STUB & PARTIAL EXTENSION 230101PROPOSED 1-1/4" PE SVC PROPOSED 1-1/4" PE STUB & PARTIAL EXTENSION THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 206.379.4347 dustin.weller@pse.com DUSTIN WELLER ROPE PROPOSED PIPE 2" MPE IP MAIN N/A N/A 1"=20'4/7 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr 109130700 RENTON Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 72" TO CLEAR BOTTOM OF FUTURE STORM AT 38" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 80" TO CLEAR BOTTOM OF FUTURE WATER AT 68" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 82" TO CLEAR BOTTOM OF FUTURE WATER AT 72" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 82" TO CLEAR BOTTOM OF FUTURE WATER AT 64" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 72" TO CLEAR BOTTOM OF FUTURE WATER AT 60" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 80" TO CLEAR BOTTOM OF FUTURE STORM AT 56" PLOT PLAN B SCALE: 1" = 20'-0" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 82" TO CLEAR BOTTOM OF FUTURE JUT AT 55" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 80" TO CLEAR BOTTOM OF FUTURE JUT AT 55"109130700KING COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP 058J CSPSKGPI 208.080 208.080/208.081 209.080/209.081SW 18-23-05 ELBOW 6"X45° MPE 110'S C/L & 48'W C/L ___'S C/L & ___'W C/L ELBOW 6"X45° MPE 101'S C/L & 39'W C/L ___'S C/L & ___'W C/L ELBOW 6"X45° MPE 101'S C/L & 44'E C/L ___'S C/L & ___'E C/L ELBOW 6"X45° MPE 92'S C/L & 53'E C/L ___'S C/L & ___'E C/L PROPOSED 1-1/8" MPE STUB & PARTIAL EXTENSION C.HAWLEY 206.809.4434 206.379.4347D.WELLER C.HAWLEY 206.809.4434 12/13/2022 12/13/2022 12/13/2022 S.ALNEEMA 253.234.6447 05/11/2023 W.JOHNSON 206.716.2730 05/15/2023 206.379.4347D.WELLER 06/05/2023 PUBLIC IMPROVEMENT 275 RAINIER AVE S, RENTON, WA 98057 RAINIER AVE S - PHASE 4 STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5GASSED UP PIPELINE PIPE SEGMENT FOREMAN'S DATENAME 45 IP058- 45 MFP23001236 S 2ND ST124175START OF JOB# 0537-1957 END OF JOB# 0878-1958 PROPOSED 1-1/4" PE SVC 225START OF JOB# 1164-1959 END OF JOB# 0878-1958IP GAS FLOWIP GAS FLOWIP GAS FLOWIP GAS FLOWIP GAS FLOWIP GAS FLOWIP GAS FLOW PROPOSED 1-1/4" PE SVC START OF JOB# 8777-1987 END OF JOB# 1164-1959 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 206.379.4347 dustin.weller@pse.com DUSTIN WELLER POLYVALVE 2" MPE (OPEN) WITH VALVE BOX & SUPPORT 10'N C/L & 55'E C/L ____'N C/L & ____'E C/L ROPE PROPOSED PIPE 2" MPE IP MAIN N/A N/A 1"=20'5/7 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr 1 5 (____')(____')(____') 109130700 RENTON TIE IN TEE 6"X6" INLINE TEE 10'N C/L & 50'E C/L ____'N C/L & ____'E C/L END OF S 2ND ST JOINT TRENCH 22'N C/L & 108'E C/L ____'N C/L & ____'E C/L END OF S 2ND ST JOINT TRENCH 10'N C/L & 108'E C/L ____'N C/L & ____'E C/L TRANSITION FITTING 2" MPE 33'N C/L & 112'E C/L ____'N C/L & ____'E C/L CP WIRE #10 TEST LEAD & CP TEST LEAD BOX COMPLETE ___'N C/L & ___'E C/L TIE IN STOPPER 2"X150 B/O & ELBOW 2"X90° WELD 35'N C/L & 114'E C/L ____'N C/L & ____'E C/L TEE SVC 1/2"X5/8" PE OUTLET (GAUGE TEE) ____'N C/L & ____'E C/L CUT & CAP CAP 2" WELD 35'N C/L & 112'E C/L ____'N C/L & ____'E C/L DEACTIVATE IN PLACE EXISTING 2" STW IP MAIN TEE TAP 2"X5/8" MPE (PURGE TEE) ____'N C/L & ____'E C/L Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 PLOT PLAN C SCALE: 1" = 20'-0" Scale: NTS TIE IN DETAIL1 5 ELBOW 2"X90° MPE 10'N C/L & 114'E C/L ___'N C/L & ___'E C/L 109130700TEST AND TIE INTO NEW MAIN TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 72" TO CLEAR BOTTOM OF FUTURE WATER AT 60" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 72" TO CLEAR BOTTOM OF FUTURE STORM AT 46" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 78" TO CLEAR BOTTOM OF FUTURE WATER AT 66" KING COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP 058J CSPSKGPI 208.080 208.080/208.081 209.080/209.081SW 18-23-05 TIE IN TEE HV 6"X2" MPE 78'N C/L & 25'W C/L ____'N C/L & ____'W C/L (____')END OF MAIN CAP 2" MPE 32'N C/L & 23'W C/L ____'N C/L & ____'W C/L CP TEST LEAD BOX COMPLETE (BRING WIRE UP IN BOX) ____'N C/L & ____'W C/L ELBOW 6"X45° MPE 68'N C/L & 48'E C/L ___'N C/L & ___'E C/L ELBOW 6"X45° MPE 77'N C/L & 39'E C/L ___'N C/L & ___'E C/L ELBOW 6"X45° MPE 78'N C/L & 32'W C/L ___'N C/L & ___'W C/L ELBOW 6"X45° MPE 98'N C/L & 53'W C/L ___'N C/L & ___'W C/L ELBOW 6"X45° MPE 134'N C/L & 53'W C/L ___'N C/L & ___'W C/L ELBOW 6"X45° MPE 173'N C/L & 43'W C/L ___'N C/L & ___'W C/L CP ANODE #20 PER CP REQUEST REDUCER 6"X4" MPE 10'N C/L & 52'E C/L ___'N C/L & ___'E C/L REDUCER 4"X2" MPE 10'N C/L & 54'E C/L ___'N C/L & ___'E C/L C.HAWLEY 206.809.4434 206.379.4347D.WELLER C.HAWLEY 206.809.4434 12/13/2022 12/13/2022 12/13/2022 S.ALNEEMA 253.234.6447 05/11/2023 W.JOHNSON 206.716.2730 05/15/2023 206.379.4347D.WELLER 06/05/2023 PUBLIC IMPROVEMENT 275 RAINIER AVE S, RENTON, WA 98057 RAINIER AVE S - PHASE 4 TEE TAP 2"X5/8" MPE (PURGE TEE) ____'N C/L & ____'E C/L STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5GASSED UP PIPELINE PIPE SEGMENT FOREMAN'S DATENAME 45 IP058- 45 Scale: NTS TIE IN DETAIL2 5 2 5 POLYVALVE 2" MPE (OPEN) WITH VALVE BOX & SUPPORT 75'N C/L & 25'W C/L ____'N C/L & ____'W C/L MFP23001236 RAINIER AVE S110151104HAYES PL SWRAINIER AVE SSW VICTORIA ST IP GAS FLOWIP GAS FLOW IP GAS FLOWPROPOSED 1-1/4" PE SVC PROPOSED 1-1/4" PE SVC PROPOSED 1-1/4" PE SVC THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 206.379.4347 dustin.weller@pse.com DUSTIN WELLER ROPE PROPOSED PIPE 2" MPE IP MAIN N/A N/A 1"=20'6/7 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr 109130700 RENTON Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 80" TO CLEAR BOTTOM OF FUTURE WATER AT 68" TOP OF PROPOSED 1-1/4" MPE SVC TO BE BURIED AT 80" TO CLEAR BOTTOM OF FUTURE WATER AT 62" PLOT PLAN D SCALE: 1" = 20'-0" 109130700DEACTIVATE 1/2" STW SVC JOINT TRENCH CONTINUES NORTH, NO GAS (____')Scale: NTS TIE IN DETAIL1 6 SQUEEZE BOTH SIDES & FUSE 5'N C/L & 58'W C/L ____'N C/L & ____'W C/L PROPOSED 6" PE MAIN IN JUT 1 6 CUT & CAP ON SERVICECUT & CAP CAP 2" MPE 10'N C/L & 38'E C/L ____'N C/L & ____'E C/L TIE IN TEE HV 6"X2" MPE 12'N C/L & 21'E C/L ____'N C/L & ____'E C/L END OF MAIN CAP 2" MPE 58'S C/L & 21'E C/L ____'S C/L & ____'E C/L CP TEST LEAD BOX COMPLETE (BRING WIRE UP IN BOX) ____'S C/L & ____'E C/L KING COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP 058J CSPSKGPI 208.080 208.080/208.081 209.080/209.081SW 18-23-05 ELBOW 6"X45° MPE 46'S C/L & 46'W C/L ___'S C/L & ___'W C/L ELBOW 6"X45° MPE 30'S C/L & 59'W C/L ___'S C/L & ___'W C/L PROPOSED 2" PE MAIN POLYVALVE 2" MPE (OPEN) WITH VALVE BOX & SUPPORT 3'N C/L & 21'E C/L ____'N C/L & ____'E C/L REDUCER 6"X4" MPE 9'N C/L & 21'E C/L ___'N C/L & ___'E C/L REDUCER 4"X2" MPE 6'N C/L & 21'E C/L ___'N C/L & ___'E C/L C.HAWLEY 206.809.4434 206.379.4347D.WELLER C.HAWLEY 206.809.4434 12/13/2022 12/13/2022 12/13/2022 S.ALNEEMA 253.234.6447 05/11/2023 W.JOHNSON 206.716.2730 05/15/2023 206.379.4347D.WELLER 06/05/2023 PUBLIC IMPROVEMENT 275 RAINIER AVE S, RENTON, WA 98057 RAINIER AVE S - PHASE 4 TEE TAP 2"X5/8" MPE (PURGE TEE) ____'N C/L & ____'E C/L 6"X5/8" MPE TEE (PURGE) ____'N C/L & ____'W C/L 6"X5/8" MPE TEE (PURGE) ____'N C/L & ____'E C/L 6" POLYVALVE 1'N C/L & 58'W C/L ____'N C/L & ____'W C/L 6"X1-1//8" PE TEE (PURGE) ____'S C/L & ____'W C/L 6"X5/8" MPE TEE (PURGE) ____'N C/L & ____'W C/L 6" ELECTROFUSION COUPLING 3'S C/L & 58'W C/L ____'S C/L & ____'W C/L STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5GASSED UP PIPELINE PIPE SEGMENT FOREMAN'S DATENAME 45 IP058- 45 BYPASS REVIEW BYPASS NOTES, TIE-IN DETAIL 1, SHEET 6: THE EX. 6" PE MAIN 9415836 ALONG SW VICTORIA ST IS 2 WAYS FEED IN THE SEGMENT BETWEEN HARDIE AVE SW AND RAINIER AVE S. THE SEGMENT OF THE EX. 6" PE MAIN ON SW VICTORIA ST (BETWEEN HARDIE AVE SW AND RAINIER AVE S) CAN BE TAKEN OUT OF SERVICE ON 25F DAY AND ABOVE WITHOUT INSTALLING A BY-PASS. GAUGE BOTH SIDES OF THE SQUEEZE PER PSE STANDARDS ON THE EX. 6" PE IP MAIN IN SW VICTORIA ST. IF THE PRESSURES DO NOT STABILIZE AT 37# (WEST SIDE GAUGE) AND 39# (EAST SIDE GAUGE), RELEASE THE SQUEEZE AND CALL GSI-SP FOR FURTHER INSTRUCTIONS. (EXPECTED DROP OF THE PRESSURE ON THE WEST SIDE (GAUGE) IS 2-3#) NOTE: ***WHEN THE SCHEDULE DATE IS KNOWN, PLEASE CONTACT GSI-SP FOR A CURRENT SYSTEM REVIEW TO DETERMINE IF TODAY'S REVIEW COMMENTS ARE STILL VALID AND TO CHECK THE OUT OF SERVICE SPREADSHEET TO VERIFY NO OTHER MAINS ARE OUT OF SERVICE IN THE AREA *** SYSTEM:IP-058 MAOP: 45# PROJECT IS WITHIN EMERGENCY SECTION 058J (NO NEW ISOLATION VALVES ARE REQUIRED). PIPE: N-106942858_2 GORDANA YUKOSAV GAS SYSTEMS INTEGRITY 425-241-5740 6" ELECTROFUSION COUPLING ____'N C/L & ____'W C/L 6" ELECTROFUSION COUPLING ____'N C/L & ____'W C/L MFP23001236 REN T O N A V E E X T E N SI O N IP GAS FLOW IP G A S F L O W AIRPORT WAYRAINIER AVE NRAINIER AVE SN THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) "Locates Required" "Flagging Required" Yes No Yes No Cell Phone: Project Manager Contact Information: E-Mail: Name: 206.379.4347 dustin.weller@pse.com DUSTIN WELLER ROPE PROPOSED PIPE 2" MPE IP MAIN N/A N/A 1"=20'7/7 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DESIGNED BY PUGET SOUND ENERGY UTILITIES CONTACT PHONE# JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr 109130700 RENTON Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: InfraSource Construction Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 PLOT PLAN E SCALE: 1" = 20'-0" 109130700(____')Scale: NTS TIE IN DETAIL1 7 1 7 (____')CUT & CAP CAP 4" (WELD) 30'S C/L & 133'E C/L ____'S C/L & ____'E C/L CUT & CAP CAP 4" (WELD) 30'S C/L & 161'E C/L ____'S C/L & ____'E C/L TIE IN STOPPER 4"X150 B/O 30'S C/L & 131'E C/L ____'S C/L & ____'E C/L TIE IN STOPPER 4"X150 B/O 30'S C/L & 163'E C/L ____'S C/L & ____'E C/L ELBOW 4"X90° (WELD) 30'S C/L & 131'E C/L ___'S C/L & ___'E C/L ELBOW 4"X90° (WELD) 30'S C/L & 131'E C/L ___'S C/L & ___'E C/L TEE SVC 1/2"X5/8" PE OUTLET (GAUGE TEE) ____'S C/L & ____'E C/L TEE SVC 1/2"X5/8" PE OUTLET (GAUGE TEE) ____'S C/L & ____'E C/L (__ _ _ ' )LOWER BY 1'LOWER BY 1'KING COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP 058J CSPSKGPI 208.080 208.080/208.081 209.080/209.081SW 18-23-05 32' C.HAWLEY 206.809.4434 206.379.4347D.WELLER C.HAWLEY 206.809.4434 12/13/2022 12/13/2022 12/13/2022 S.ALNEEMA 253.234.6447 05/11/2023 W.JOHNSON 206.716.2730 05/15/2023 206.379.4347D.WELLER 06/05/2023 PUBLIC IMPROVEMENT 275 RAINIER AVE S, RENTON, WA 98057 RAINIER AVE S - PHASE 4 STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5GASSED UP PIPELINE PIPE SEGMENT FOREMAN'S DATENAME 45 IP058- 45 MFP23001236