Loading...
HomeMy WebLinkAboutMFP23005973.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23005973 IVR Number: 23005973 Permit Information Permit Name: P.188718 Address/Location:11/30/2023Application Date:0823059216Parcel Number: 1107 LAKE WASHINGTON BLVD N Permit Type:12/07/2023Issue Date:Franchise Permit Work Class:12/06/2024Expiration Date:Minor Utility Job Number: P.188718Franchise Type:Telephone Description: Century Link work IN MANHOLE 326, PUSH FIBER. IN MANHOLE T 182, SPLICE FIBER TO MANHOLE T 184. IN MANHOLE T 184, SPLICE NEW FIBER CABLE TO EXISTING FIBER CABLE. IN MANHOLE 1004, PUSH FIBER CABLE. IN MANHOLE 1003, PUSH FIBER CABLE TO EXISTING FIBER CABLE . IN MANHOLE 749, PUSH FIBER CABLE TO EXISTING FIBER CABLE. IN MANHOLE 747, PUSH FIBER CABLE TO EXISTING FIBER CABLE. IN MANHOLE 734, PUSH FIBER CABLE TO EXISTING FIBER CABLE. IN MANHOLE 463, PUSH FIBER CABLE TO EXISTING FIBER CABLE. IN MANHOLE 461, PUSH FIBER CABLE TO EXISTING FIBER CABLE. Contacts Name Address PhoneTypeBilling Nathan Macleod Lumen 7850 S Trafton St, Bldg B Tacoma, WA 98409 C: (253) 583-6283ApplicantX Merilyn Luong Lumen B: (206) 806-7160 C: (206) 806-7160 Applicant CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES P.188718 1107 Lake Washington Blvd N Northsky Comm Mike Smith 12/18/2023 12/20/2023 8am 5pm 425-615-7121 Access existing MHs for splicing. MFP23005973 VANCOUVER WA 98683-346216701 SE MCGILLIVRAY BLVD Scott Warlick CED 12/7/2023 8:00AM - 3:00PM Merilyn Luong 12/5/2023 Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton KingP.188718 98057 All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 Scope of Work: Manhole Access Traffic Control Plan: Cover Sheet General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. COVER SHEET SHEET 1 SHEET 2 SHEET 3/4 SHEET 5 SHEET 6/7 www.invarion.comMFP23005973 Imagery and map data ©2023, Google Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton KingP.188718 98057 All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 Scope of Work: Manhole Access Traffic Control Plan: One Lane Closure NE 27TH ST30MPH NE 27TH ST30MPH General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. 01 OF 07 Legend Cone Flagger MH MH 326 Sign Stand Work Area 2609 EDMONDS AVE NE 2616 EDMONDS AVE NE 2601 NE 27TH ST 2601 EDMONDS AVE NE Plan Scale 1 : 600 (1'' = 50') EDMONDS AVE NE30MPH 11/29/2023 by: Elite Traffic Solutions206.922.9205 Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ MH 35' 8' 10' 12' 50' TO 100'6 DEVICES MIN X X X ONE LANEROADAHEAD W20-4 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 W20-7aROAD WORKAHEAD W20-1 W20-7a ONE LANEROAD AHEAD W20-4 ONE LANEROADAHEAD W20-4 W20-7a X X X 50' TO 300' X X X www.invarion.com MFP23005973 Imagery and map data ©2023, Google Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton KingP.188718 98057 All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 Scope of Work: Manhole Access Traffic Control Plan: Shoulder Lane Closure N 28TH PL25MPH N 28TH ST25MPH General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. 02 OF 07 PARK AVE N25MPH 1306 N 28TH ST 2802 PARK AVE N 1215 N 28TH PL 1303 N 28TH ST Legend Cone MH MH T-182 Sign Stand Work Area Plan Scale 1 : 600 (1'' = 50') 11/29/2023 by: Elite Traffic Solutions206.922.9205 Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ MH 35'8' SHOULDERCLOSED W21-5 L/3 X X ROADWORKAHEAD W20-1 ROAD WORKAHEAD W20-1 ROADWORKAHEAD W20-1 www.invarion.com MFP23005973 Imagery and map data ©2023, Google Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton KingP.188718 98057 All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 Scope of Work: Manhole Access Traffic Control Plan: Right Lane Closure General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. 03 OF 07 N 20TH ST15MPH Legend Cone MH MH 479 Sign Stand Work Area 1300 N 20TH ST 1303 N 20TH ST Plan Scale 1 : 600 (1'' = 50') 11/29/2023 by:Elite Traffic Solutions 206.922.9205Julian Morales TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ MH 35' 8'11' X ROAD WORK AHEAD W20-1 ROADWORK AHEAD W20-1 X X ROAD WORK AHEAD W20-1 X X X RIGHT LANE CLOSEDAHEAD W20-5 RIGHT LANECLOSEDAHEAD W20-5 BIKESMERGE WITHTRAFFIC W4-1b BIKE LANE ENDS W9-1b X X W1-4 W1-4 LEFT LANECLOSEDAHEAD W20-5 W4-2 X X X L L/2 B LAKE WASHINGTON BLVD N25MPH www.invarion.com MFP23005973 Imagery and map data ©2023, Google Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton KingP.188718 98057 All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 Scope of Work: Manhole Access Traffic Control Plan: Right Lane Closure L A K E W A S H I N G T O N B L V D N 2 5 M P H General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. 04 OF 07 Legend Cone Flagger MH MH 747 Sign Stand Work Area 2100 LAKE WASHINGTON BLVD N Plan Scale 1 : 600 (1'' = 50') BELLA VISTA LAKE WASHINGTON APTS 11/29/2023 by:Elite Traffic Solutions 206.922.9205 Julian Morales TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ MH 35' 8' 50' TO 100' 6 DEVICE MIN 11' 50' TO 100' 6 DEVICES MIN 50' TO 300' X ROADWORK AHEAD W20-1 ROADWORK AHEAD W20-1 X X W20-7a W20-7a ONE LANE ROADAHEAD W20-4 ONE LANEROAD AHEAD X X X www.invarion.com MFP23005973 Imagery and map data ©2023, Google Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton KingP.188718 98057 All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 Scope of Work: Manhole Access Traffic Control Plan: Shoulder Lane Closure LAKE WASHINGTON BLVD N25MPH General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. 05 OF 07 Legend Cone MH MH 734 Sign Stand Work Area RESIDENCE INN BY MARRIOTT SEATTLE SOUTH/RENTON Plan Scale 1 : 600 (1'' = 50') HAMPTON INN & SUITES/RENTON 1322 LAKE WASHINGTON BLVD N 11/29/2023 by:Elite Traffic Solutions 206.922.9205 Julian Morales TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ MH 35' 8' L/3 ROAD WORKAHEAD W20-1 X X ROAD WORK AHEAD W20-1 50'NO P ARK24 HRSNOPARKINGFROM TO TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555 R7-T39 SHOULDERCLOSED www.invarion.comMFP23005973 Imagery and map data ©2023, Google Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton KingP.188718 98057 All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 Scope of Work: Manhole Access Traffic Control Plan: Right Lane Closure SOUTHPORT DR N 30MPH General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. 06 OF 07 Legend Bus Stop Cone MH MH 461 Sign Stand Traffic Light Work Area GRIFFIS LAKE WASHINGTON Plan Scale 1 : 600 (1'' = 50') 1000 GARDEN AVE N LAKE WASHINGTON BLVD N25MPH 11/29/2023 by: Elite Traffic Solutions206.922.9205 Julian MoralesTCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ MH 35' 8' ROAD WORK AHEAD W20-1 X X X RIGHT LANECLOSEDAHEAD W20-5 W4-2 ROAD WORK AHEAD W20-1 W4-119 (L) www.invarion.com MFP23005973 Imagery and map data ©2023, Google Traffic Control Planner Elite Traffic Solutions 206-922-9205 julian@elitetrafficsolutions.com Renton KingP.188718 98057 All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards. BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 Scope of Work: Manhole Access Traffic Control Plan:Alternating Lane Closure w/ Flaggers General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways. 9. Traffic Control Supervisor required for ROW impacts. 07 OF 07 Legend Cone Flagger MH MH CB0 1 Sign Stand Work Area WIZARD OF THE COAST LLC Plan Scale 1 : 600 (1'' = 50') 1000 GARDEN AVE N LAKE WASHINGTON BLVD N25MPH 1101 LAKE WASHINGTON BLVD N 920 LAKE WASHINGTON BLVD N 11/29/2023 by:Elite Traffic Solutions 206.922.9205 Julian Morales TCS #012813Jʅʙiʋɚ Mʝrɪȵeɡ MH 35'8'50' TO 100' 6 DEVICES MIN ROAD WORKAHEAD W20-1 X X X ONE LANEROAD AHEAD W20-4 W20-7a X X X ROADWORK AHEAD W20-1 ONE LANEROADAHEAD W20-4 W20-7a 50' TO 300' www.invarion.com MFP23005973 Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) ConeSSpotter truck Work Area TRAFFIC CONTROL PLAN JOB # N.991223 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 NOT TO SCALE Sharon Martos Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com LAKE WA BLVD N @ HOUSER WAY N MH 463 RIGHT LANE CLOSURE SPEEDLIMIT 25 Comments: ACCESS MH 463.WEST SIDE LAKE WA BLVD N, SOUTH OF HOUSER WAY N. RIGHT LANE CLOSUREBIKES MERGE WITH TRAFFIC. SIDEWALK CLOSED.CURB RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.RRDETOURM4-9bDETOURM4-9bMH 463 WORK AREA 10 X 155 S W4-2RIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1100'100'100'105' LAKE WA BLVD N HOUSERW A Y N100'Nwww.invarion.com MFP23005973 Additional approval may be needed from BNSF for work in their ROW Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Cone S Spotter truck Work Area TRAFFIC CONTROL PLAN JOB # N.991223 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 NOT TO SCALE Sharon Martos Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com LAKE WA BLVD N @ BURNET T AVE N MH 1003 SHOULDER WORK SPEEDLIMIT 25 S MH 1003 WORK AREA8 X 40 ROADWORKAHEADW20-1SHOULDERWORKW21-5100'ROADWORKAHEADW20-1DWY LAKE WA BLVD N DWY BURNETT AVE NComments: ACCESS MH 1004. WEST SIDE LAKE WA BLVD N, SOUTHOF BURNETT AVE N. SHOULDER WORK.BIKE LANE ACCESSIBLE. SPOTTER WILL ASSIST PEDESTRIANS.Nwww.invarion.com MFP23005973 Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Cone S Spotter truck Work Area TRAFFIC CONTROL PLAN JOB # N.991223 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 NOT TO SCALE Sharon Martos Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com LAKE WA BLVD N @ BURNET T AVE N MH 1004 SHOULDER WORK Comments: ACCESS MH 1004. WEST SIDE LAKE WA BLVD N, SOUTHOF BURNETT AVE N. SHOULDER WORK.BIKE LANE ACCESSIBLE. SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT 25 S MH 1004 WORK AREA8 X 40 ROADWORKAHEADW20-1SHOULDERWORKW21-5100'DWYROADWORKAHEADW20-1LAKE WA BLVD N BURNETTAVENNwww.invarion.com MFP23005973 Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Cone S SPOTTER Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.991223 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60NOT TO SCALE Sharon Martos Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com PARK AVE N @ N 28T H ST MH T-182 SHOULDER WORK Comments: ACCESS MH T-182SOUTH SIDE N 28TH ST @ PARK AVE N. SHOULDER WORK.SPOTTER WILL ASSIST PEDESTRIANS. N 28TH STPARK AVE NN 28TH PL ROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5ROADWORKAHEADW20-1NSPEEDLIMIT 25 100' MH T-182 WORK AREA 10 X 40 S www.invarion.com MFP23005973 Date:4/25/2022 Author:Sharon Martos, Traffic Control Supervisor Project:N.991223 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Cone Flagger Work Area Work Truck TRAFFIC CONTROL PLAN JOB # N.991223 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 NOT TO SCALE Sharon Martos Project # N.991223 C.45Designed for LUMENSharon MartosApproved 4/25/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com BURNETT AVE N @ N 28TH PL MH T-184 ONE LANE 2-WAY Comments: ACCESS MH T-184. WEST SIDE BURNETT AVE N @ N 28TH PL. ONE LANE 2-WAY WITH FLAGGERS. FLAGGERS WILL ASSIST PEDESTRIANS.ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7aR O A D W O R K A H E A D W 2 0 -1 B E PR E P A R E D TO S T O P W 2 0 -7b W2 0 - 7 a N 27TH PLN 28TH PLN 29TH STALLEYROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1ROADWORKAHEADW20-1BE PREPAREDTO STOP W20-7b W20-7a100' 100' BURNETT AVE N ROADWORKAHEAD W20-1 SPEEDLIMIT 25 MH T-184 WORK AREA 10 X 90 100' 100' 100'100'Nwww.invarion.com MFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.14400000000”NVICINITY MAPFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMSCOPE OF WORK:LSH24, 17-18. IN MANHOLE 326, PUSH LSH24, 17-18 FROM EXISTING FIBER CABLE [QD68] TO EXISTING FIBER CABLE [QD67]. IN MANHOLE T-182, SPLICE FIBERCABLE [QD67] TO NEW FIBER CABLE BEING PLACED APPROX. 1440' THROUGH EXISTING CONDUIT TO MANHOLE T-184. IN MANHOLE T-184, SPLICE NEWFIBER CABLE TO EXISTING FIBER CABLE [TTP6]. IN MANHOLE 1004, PUSH FIBER CABLE [TTP6] TO EXISTING FIBER CABLE [TTN3]. IN MANHOLE 1003, PUSHFIBER CABLE [TTN3] TO EXISTING FIBER CABLE [TTN2]. IN MANHOLE 749, PUSH FIBER CABLE [TTN2] TO EXISTING FIBER CABLE [TTN1]. IN MANHOLE 747,PUSH FIBER CABLE [TTN1] TO EXISTING FIBER CABLE [A3DAQ]. IN MANHOLE 734, PUSH FIBER CABLE [A3DAQ] TO EXISTING FIBER CABLE [A3DEL]. INMANHOLE 463, PUSH FIBER CABLE [A3DEL] TO EXISTING FIBER CABLE [TTM9]. IN MANHOLE 461, PUSH FIBER CABLE [TTM9] TO EXISTING FIBER CABLE[A3LNZ]. IN CBO1, PUSH FIBER CABLE [A3LNZ] TO EXISTING FIBER CABLE [A3LPF]. IN ACCESS POINT, PUSH FIBER CABLE [A3LPF] TO EXISTING FIBER CABLE[A3LP5].FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057112RMFP23005973 TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L B/C B/C B /C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057212RMFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W T35'6'2632#04230591392609#3343900041#04230593042424#334390000516'42'28'27'30'29'32'NOTE:LSH24, 17-18. IN MANHOLE 326, PUSH LSH24,17-18 FROM EXISTING FIBER CABLE [QD68] TOEXISTING FIBER CABLE [QD67].SPEEDLIMITSPEEDLIMITSPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057312RMFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSMATCH SHEET 5 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W T24'24'26'26'24'12'1215#3342100725164450TR-B1303#05230590561307#0523059060#33421033011306#3342103285NOTE:1400' OF NEW48F IN EX UG.NOTE:IN MANHOLE T-182, SPLICE FIBER CABLE [QD67]TO NEW FIBER CABLE BEING PLACED APPROX.1440' THROUGH EXISTING CONDUIT TOMANHOLE T-184.SPEEDLIMITSPEEDLIMITSPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057412RMFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS EOP EOP R/W R/W R/W R/W R/W EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W EOP EOP R/W R/W R/W EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W EOP R/W R/W R/W T905#3342100615900#16445002802807#33421005802803#3342100595#062305900122'15'32'30'18'30'MATCH SHEET 4 NOTE:IN MANHOLE T-184, SPLICE NEW FIBERCABLE TO EXISTING FIBER CABLE [TTP6].SPEEDLIMITSPEEDLIMITSPEEDLIMITSPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057512RMFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W TT#0523059003#2296500185#22965001804'4'NOTE:IN MANHOLE 1004, PUSH FIBER CABLE [TTP6] TOEXISTING FIBER CABLE [TTN3]. IN MANHOLE 1003,PUSH FIBER CABLE [TTN3] TO EXISTING FIBER CABLE[TTN2].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057612RMFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN MANHOLE 749, PUSH FIBER CABLE[TTN2] TO EXISTING FIBER CABLE [TTN1].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057712R EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W R/W EOP EOP EOP EOP T55'30'33'3'6' S/W20'49'60'3'SPEEDLIMIT#05230590031303#33445003151303#3344500315MFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS1400#33445000390NOTE:IN MANHOLE 747, PUSH FIBER CABLE [TTN1]TO EXISTING FIBER CABLE [A3DAQ].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057812R EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP T24'35'25'4' GRASS6' S/W11'175'#0523059003MFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS1322#3344500005NOTE:IN MANHOLE 734, PUSH FIBER CABLE[A3DAQ] TO EXISTING FIBER CABLE [A3DEL].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 98057912R EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W T24'34'33'25' PARKING420'TOHOUSERWAY4' BIKE LANE#3344500007MFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS EO P EOP EOP EOP EOP T R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 3'135'6' S/W55'48'#08 2 3 0 5 9 0 2 7 #082 3 0 5 9 1 9 1 NOTE:IN MANHOLE 463, PUSH FIBER CABLE[A3DEL] TO EXISTING FIBER CABLE [TTM9].SPEEDLIMITSPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 980571012RMFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSSH IP P ING Y ARDT E O P EOP EOP R/W R/W R/W R/W EOP EOP PWR STATION BOEINGNOTE:IN MANHOLE 461, PUSH FIBER CABLE[TTM9] TO EXISTING FIBER CABLE [A3LNZ].SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 980571112RMFP23005973 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN CBO1, PUSH FIBER CABLE [A3LNZ] TO EXISTINGFIBER CABLE [A3LPF]. IN ACCESS POINT, PUSH FIBERCABLE [A3LPF] TO EXISTING FIBER CABLE [A3LP5].TTO L A K E W A S H I NG TO N B L V D N 111111071103SPEEDLIMITFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMFIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400DRAFTED BY: MOUNTAIN LTD/DL - 11/22/2323N5E8P.188718W26226RNTNWA011107 LAKE WASHINGTON BLVD NRENTON, WA 980571212RMFP23005973